Description
The TBMA is a sheathed thermocouple with a flexible protection tube and a fixed connection cable.
It measures in installation locations that a rigid protection tube cannot reach. The sheathed tube can be bent to a radius of min. 5 × Ø protection tube; the cable is firmly attached to the sensor, eliminating the need for a connection head that requires space and wall clearance. The protection tube is made of 2.4816 (Inconel 600), specified as a material up to 1100 °C, the connecting sleeve is made of 1.4571 (316Ti), the protection class is IP 65 up to 250 °C. Available in four diameters from 1.5 to 6 mm and with a nominal length of 100 mm as standard, up to 2000 mm on request, it also fits into narrow and deep bores. Clamp fittings and sheet metal flanges from the accessories are used for fastening.
For Ø 3 mm, the response time is t90 5 s and t50 2 s – meaning the sensor still responds usefully to rapid temperature changes. Connection is via open ends or via TE connectors in standard or mini design; five cable versions from PVC to glass silk are available, with a standard length of 2 m.
The measuring element is a Type J (Fe-CuNi) or Type K (NiCr-Ni) thermocouple, insulated in metal oxide. The operating range for Type J is from -200 … +700 °C, for Type K from -200 … +1000 °C. The limit deviation follows DIN EN 60584-2 Class 1: ±1.5 °C in the range -40 … 375 °C, above that ±0.004|t|. The sensor directly outputs the thermovoltage and has no transmitter; the insulation is tested with 500 VDC.
Please note before ordering: The operating range is determined by the cable, not the sensor – PVC ends at +70 °C, silicone at +180 °C, PTFE at +250 °C, glass silk at +550 °C. If you want to utilize the +1000 °C of Type K, you will not find a suitable cable in this cable range; for PTFE, the sister sheets specify +205 °C, the value from this source is adopted. IP 65 does not apply to the version with braided shield; the protection class applicable there is available on request. For Type J, the operating range up to 700 °C is decisive. Terminal assignment, process connection, system pressure and weight are available on request. A declaration of conformity is available on request. Explosion protection is not documented. The version with GL type approval is the TBMB.
Advantages at a glance
- Thermocouple Type J or Type K, -200 … +1000 °C
- Limit deviation Class 1 according to DIN EN 60584-2, ±1.5 °C from -40 °C
- Flexible sheathed tube, bending radius min. 5 × Ø protection tube
- Four diameters 1.5 · 3 · 4.5 · 6 mm, nominal length up to 2000 mm
- Response time for Ø 3 mm t90 5 s and t50 2 s
- Protection tube 2.4816 (Inconel 600), material up to 1100 °C
- GL version available as TBMB