Description
The LKAD is a round compression load cell of stainless steel with a loading head, made for nominal loads from 100 kg to 200 t. Its accuracy is stated to OIML R60 in three classes — C1 with 1000, C2 with 2000 and C3 with 3000 legal divisions — and the minimum verification interval is Emax divided by 10000 in every class. The nominal output is 2 mV/V with a calibration tolerance of ± 0.1 %, input and output resistance are 700 Ω each, and the cell carries 120 % of its nominal load in service and more than 300 % before it breaks. The body is sealed to IP68, tested for 100 hours under a metre of water, and the standard output is five metres of shielded PVC cable; a MIL6M or an M12 connector is available instead. A loading head, a mounting plate and a complete weighing unit are offered for each load group, so that four cells carry a tank without further parts.
Measurement and accuracy
- Nominal load 100 kg … 200 t in 15 steps
- OIML R60 class C1, C2 or C3
- 1000, 2000 or 3000 legal divisions
- Vmin = Emax / 10000 in every class
- Nominal output 2 mV/V ± 0.1 %
- Input and output resistance 700 Ω ± 2 Ω
- Combined error from ± 0.045 % (C1)
- Service temperature −20 … +70 °C
Mechanics, sealing and mounting
- Stainless steel body, IP68 to EN 60529
- Service load 120 %, breaking load > 300 %
- Max. transverse load 50 % of nominal load
- Displacement 0.06 … 0.36 mm at nominal load
- Fixing screws M8 or M16, class 12.9
- Weight 1.3 … 18.2 kg by load group
- 5 m shielded cable, 10 m on request
- MIL6M or M12 connector on request