TXMA rail temperature sensor


Price:
Price on request

Configuration for your inquiry

Your details are sent to us with your inquiry. All versions are made to order — you will receive a quotation.

At this position the source refers to a footnote (6) that is not given on the sheet.

The measuring range is configurable and is set to -30…+60 °C at the factory.

The housing fits S 49, S 54, UIC 60 and R 65 without modification. Mounting with claw and counter claw, M10 threaded rod, tightening torque 68 Nm.

Here the source lists only position 0, meaning special model; please describe what should differ.

Request a quote
Questions about this product? +43 676 362 8453 office@octogon.org

Delivery Time & Shipping

Downloads

Not the right fit? No problem. We build everything! Just ask.

Description

The TXMA is a rail temperature sensor for railway applications. It measures the temperature of the running rail and provides the measured value that controls the point heating system.

The housing fits rail profiles S 49, S 54, UIC 60, and R 65 without modification. It is fastened with a clamp and counter-clamp using an M10 threaded rod of strength class 10.9, tightening torque 68 Nm; installation must be below the heating element, otherwise, the sensor will measure the heating system instead of the rail. The housing measures 68 × 64 mm, is fully potted, made of material x 25 CrNiSi 18.9 and weighs approximately 1.5 kg; the operating temperature ranges from -40 … +85 °C, optionally -50 … +105 °C.

There is no plug: The connection cable H07BQ-F, 2 × 1.5 mm² is led out of the potting via a PG 11 screw connection. The output is galvanically isolated, the insulation voltage is 1500 VAC for 60 s – in the track, where traction currents and return current flow, this is the decisive value.

A Pt100 in 4-wire Class A configuration is installed in the housing as the measuring element. The measuring range is configurable and set ex works to -30 … +60 °C, the resolution is 0.1 °C, and the measurement deviation is less than ±0.05 % of the measuring span. The output is 4 … 20 mA in 2-wire technology, reversible to 20 … 4 mA, with output limits 3.8 … 20.5 mA according to NAMUR. The sensor is powered with 9 … 36 VDC.

Note before ordering: Number and date of the "Technical Approval from Deutsche Bahn AG" as well as information on the railway standards EN 50121, EN 50155, and EN 45545 are available on request; proof must be requested before use in railway applications. The 1500 VAC for 60 s is insulation voltage, not continuous operating insulation; overvoltage category and lightning protection are available on request. The housing is fully potted; the degree of protection is available on request. To change the measuring range, the configuration set with DTM-Control software is required, connection via RS 232-C; if configured during operation, the connection to the point heating control is interrupted, and whether the set is still available can be clarified on request. A declaration of conformity is available on request. Explosion protection is not documented.

Advantages at a Glance

  • Fits S 49, S 54, UIC 60, and R 65 without modification
  • Pt100 4-wire Class A, resolution 0.1 °C
  • 4 … 20 mA, reversible to 20 … 4 mA, limits 3.8 … 20.5 mA according to NAMUR
  • Galvanically isolated, insulation voltage 1500 VAC for 60 s
  • Housing 68 × 64 mm stainless steel, fully potted, approx. 1.5 kg
  • Clamp with M10 threaded rod, tightening torque 68 Nm

Another product?