Description
The LPLA is a load pin made of 17-4PH stainless steel (1.4542) for rated capacities of 5 t, 10 t and 20 t (50, 100 and 200 kN). A load pin, also called a load measuring pin, takes the place of a load-bearing pin and measures the force passing through it.
Typical applications
- Machines, lifting equipment and test benches in which the force is carried by a pin
- Load monitoring and overload protection
Benefits at a glance
- Rated capacities 5 t, 10 t and 20 t (50, 100 and 200 kN)
- Combined error no more than ± 0.1 % of the rated capacity
- Rated output 1.0 mV/V ± 0.1 %
- 17-4PH stainless steel (1.4542), protection rating IP67
- 10 m cable, six-wire technique
- Factory calibrated
Mechanics and environment
The pin withstands a service load of 120 %, a safe overload of 150 % and a breaking load of more than 400 % of the rated capacity. The maximum lateral load is 50 %, the maximum dynamic load 70 % of the rated capacity. The compensated temperature range is −20 … +70 °C, the operating temperature −30 … +90 °C. The dimensions are shown in the dimensional drawing and in the datasheet.
Connection
Wheatstone full bridge in six-wire technique, recommended excitation voltage 5 … 15 V. Wire colours: excitation + red, sense + blue, excitation − black, sense − brown, signal + green, signal − white.
Options on request
- Calibration by a laboratory accredited to ISO/IEC 17025
- Versions for potentially explosive atmospheres: ATEX (zone 2-22) and ATEX/IECEx (zone 1-21)
Frequently asked questions
Does the LPLA fit my pin connection? The LPLA has fixed dimensions, shown in the dimensional drawing. If it does not fit, octogon manufactures load pins made to measure.
Do I need a measuring amplifier? Yes. The LPLA supplies an mV/V signal that is evaluated by a measuring amplifier or weighing transmitter.
Conformity: CE, RoHS and REACH. A declaration of conformity is available on request.