Description
The EKMD is a bare board for installation in a device of your own: 40 × 17 × 6.5 mm, six solder pads, no case. It measures either with one Pt100 in three-wire connection over −200 to 800 °C or with a thermocouple of type J, K or N, together covering −200 to 1372 °C, and passes the value on over IO-Link with a signal level of 0 / 24 V. The amplifier resolves 16 bit and adds at most 0.02 % of the nominal range to the sensor error; the response time is 20 ms, the filter setting 25 s. Supply is 24 V DC with less than 30 mA in normal operation and at most 130 mA in total when the switching output is loaded; reverse polarity does not destroy the board. Case, protection class and terminals come from the device the board is built into.
Measurement and interface
- Pt100, 3-wire, −200 … 800 °C
- Type J −210 … 1200 °C
- Type K −200 … 1372 °C
- Type N −200 … 1300 °C
- Accuracy max. 0.02 % of nominal range
- Resolution 16 bit, response time 20 ms
- IO-Link, signal level 0 / 24 V
- Filter setting 25 s
Board and supply
- Dimensions 40 × 17 × 6.5 mm, approx. 3.4 g
- No case — IP00, protection from the installation
- Solder pads 2.7 × 1.5 mm
- Supply 24 V DC
- Current < 30 mA, total max. 130 mA
- Reverse polarity protection
- Operating temperature −20 … +80 °C
- EN 61000-6-4 and EN 61000-6-2
All technical data, dimensions and available versions are listed in the datasheet for download.