Load Cells & Force Transducers

164 products

Showing 1 - 24 of 164 products

Showing 1 - 24 of 164 products
View
Miniatur Zug-Druck-Kraftaufnehmer LSBA FSA
LSBA miniature force transducer
Sale price577,50 EURNet, excl. shipping
Choose options
LSLA_L-CTL Zuglast- und Drucklast-Wägezelle
LSLA tension and compression load cell, 17-4PH stainless steel, IP68
Sale priceFrom 281,00 EURNet, excl. shipping
Choose options
Miniatur Zug-Druck-Kraftaufnehmer LZBA FZA
LZBA compact tension and compression load cell, IP66
Sale price194,60 EURNet, excl. shipping
Choose options
LCLE_L-AS Plattform-Wägezelle
LCLE single point load cell
Sale price66,00 EURNet, excl. shipping
Choose options
Zug-Druck-Kraftsensor LZBF FZF
LZBF tension and compression load cell, IP67
Sale price269,00 EURNet, excl. shipping
Choose options
LMLAW_V10275EN1090 Wägemodul für Drucklast-Wägezellen - niedriges Profil nach EN 1090
LMLAW weighing module for compression load cell up to 15 t, EN1090
Sale priceFrom 253,00 EURNet, excl. shipping
Choose options
LKLA_CBL Drucklast-Wägezelle
LKLA compression load cell
Sale priceFrom 286,00 EURNet, excl. shipping
Choose options
LMLBC_V15000_V100000EN1090 Wägemodul für Drucklast-Wägezellen - niedriges Profil nach EN 1090, Produktfoto
LMLBC weighing module for compression load cell 30 to 100 t, EN1090
Sale priceFrom 420,00 EURNet, excl. shipping
Choose options
Verstellbarer Kugelgelenkfuß L-SB2-PXC
L-SB2-PXC adjustable ball joint foot
Sale priceFrom 33,00 EURNet, excl. shipping
Choose options
LCLC_L-AM Plattform-Wägezelle
LCLC single point load cell
Sale price88,00 EURNet, excl. shipping
Choose options
Kugelgelenk L-EM-DADO für Wägezellen
Ball joint for load cells
Sale priceFrom 18,00 EURNet, excl. shipping
Choose options
Kraftmessring LRBB FRB
LRBB ring load cell 10 to 2,000 kg
Sale price329,00 EURNet, excl. shipping
Choose options
Miniatur-Kraftmessdose LKBC FKB, Ansicht 1Miniatur-Kraftmessdose LKBC FKB, Ansicht 2
LKBC miniature compression load cell
Sale price215,00 EURNet, excl. shipping
Choose options
LCLF_L-AZL Plattform-Wägezelle
LCLF single point load cell
Sale price88,00 EURNet, excl. shipping
Choose options
LCLB_L-ALL Plattform-Wägezelle
LCLB single point load cell, class C3 to C5
Sale price77,00 EURNet, excl. shipping
Choose options
Scherstab-Wägezelle LBLF L-FTK
LBLF shear beam load cell
Sale priceFrom 143,00 EURNet, excl. shipping
Choose options
LBLA_FTP Scherstab-/Biegestab-Wägezelle aus Edelstahl AISI 420, 75–5000 kg (0,75–50 kN), Genauigkeitsklasse C3; Produktbild
LBLA shear and bending beam load cell
Sale priceFrom 176,00 EURNet, excl. shipping
Choose options
LKLE compression load cell
LKLE compression load cell
Sale priceFrom 330,00 EURNet, excl. shipping
Choose options
LKLC compression load cell
LKLC compression load cell
Sale priceFrom 237,00 EURNet, excl. shipping
Choose options

Frequently asked questions

What is the difference between a load cell and a force transducer?

Technically it is the same component: a spring element with bonded strain gauges that deform under load and detune the bridge voltage. The difference lies in the labelling and the calibration. A load cell is calibrated in units of mass (kg, t) and intended for weighing; a force transducer is calibrated in units of force (N, kN) and intended for force measurement on test benches, presses or machines. If you want to measure a force, take a force transducer – otherwise gravitational acceleration travels along as a conversion error.

How many load cells do I need for a tank or silo?

Round tanks usually stand on three load cells, rectangular ones on four. Three support points are statically determinate and need no compensation; four distribute the load better on a large footprint but require an even bearing surface. The capacity per cell follows from the empty weight plus the maximum fill weight divided by the number of supports, plus a reserve for agitators, attachments and off-centre filling. Ready-made weighing modules are available for the installation and take care of pendulum movement and uplift protection.

Which rated capacity should I choose?

The rated capacity should be above the largest expected load, but not arbitrarily far above it: an oversized cell uses only part of its measuring range, and the absolute deviation grows with it. As a rule of thumb, plan the maximum load at 70 to 80 percent of the rated capacity and add dead weights, dynamic shocks and off-centre loading. The safe load limit in the data sheet matters as well – up to that point the cell tolerates overload without lasting damage.

Does octogon also build force transducers to drawing?

Yes. When no standard design fits the available space, octogon manufactures custom force transducers and load cells – from the design of the spring element and the CNC machining through to the application of the strain gauges and the calibration. The reverse is possible too: if there is no room for a sensor at all, strain gauges are applied directly to an existing machine part, and that part becomes the measuring element.

Recently viewed

Nothing found? We develop measurement systems specifically for your application!