TSMB spring-loaded surface sensor with IO-Link

  • Output: IO-Link

Price:
Sale price224,00 EUR

Net, excl. shipping

Configuration for your inquiry

The standard version is preselected. Change only what you need — surcharges are added to your order automatically.

The only option.

The only option.

Position X applies to thermocouples; the source names no class for them.

Other lengths in 5 mm steps, please specify.

The process connection does not seal; system pressure is not possible.

Plastic is the standard version; the source text describes the metal insert as stainless steel.

The only option; no other connector type is provided for this version.

For custom, please state the required measuring range.

If yes, please describe what should differ.

Base price (standard version)224.00 EUR
Configured price 224.00 EUR
Questions about this product? +43 676 362 8453 office@octogon.org

Delivery Time & Shipping

Not the right fit? No problem. We build everything! Just ask.

Description

The TSMB is a contact sensor with a spring-loaded measuring tip and an IO-Link interface.

It measures on the surface and in bearings: The compression spring holds the measuring tip with a 14 mm travel (±1 mm) at the measuring point, even if the component moves or expands due to heat – a rigidly screwed-in sensor would lose contact in such a situation. The sensor tube measures Ø 6 mm made of stainless steel 1.4571, the compression spring is made of spring steel 1.4310, the protection class is IP 65 / IP 68, the installation length is 45 or 65 mm, the weight is approximately 200 g.

The mechanics are the same as with the TSMA; instead of a HART transmitter, an IO-Link transmitter is installed here. The measured value is sent digitally to the IO-Link master, and the sensor is also parameterized there – a configuration device is not necessary, the description of the values is in the device file IODD. The electrical connection is M12x1 four-pin as the only option; the sensor does not have a display or limit contacts.

The input has a Pt100 in a 3-wire circuit or a thermocouple Type J, K or N. The nominal range extends from -50 … +150 °C in all versions; a measuring range of 0 … 100 °C is set ex works, customizable. The source states the accuracy as max. 0.02 % of the range plus sensor error at 16 Bit and 20 ms response time, powered by 24 VDC with reverse polarity protection.

Note before ordering: This sensor does not withstand process pressure: system pressure is not possible, the process connection has no sealing effect; the Pressure Equipment Directive is therefore not applicable. The ambient temperature is not the medium temperature: The electronics in the head tolerate -20 … +80 °C, the medium up to +150 °C; the neck length or insulation required for this is available on request. The accuracy specification is remarkably favorable: 0.02 % of the range at 16 Bit, while the sister sheets with 24 Bit only guarantee 0.1 % and the TSMA with the same design states 0.3 % – before designing, the value must be confirmed with the manufacturer, the sensor error is always added. The relationship between filter and response time is also striking: 25 s filter at 20 ms response time. The minimum span is available on request. A declaration of conformity is available on request. Explosion protection is not documented.

Advantages at a glance

  • Spring-loaded measuring tip, travel 14 mm ±1 mm
  • IO-Link with signal level 0/24 V, parameterization via the master
  • Range -50 to +150 °C, factory setting 0 … 100 °C
  • Installation length 45 or 65 mm, sensor tube Ø 6 mm made of 1.4571
  • Version with HART available as TSMA

Another product?