Description
The TNMA is an immersion thermometer in the form of a handheld lance with HART.
It is designed for mobile use – hay, compost, hot asphalt: The lance is inserted into the material until the tip is deep enough. It is available in lengths from 500 to 2000 mm and upon request, with Ø 10 mm made of stainless steel 1.4571. The weight is approximately 845 g (1000 mm with display), the protection class is IP 65 for the electronics and IP 68 for the sensor.
The process connection is explicitly designed as a handheld lance, no installation: There are no threads or sealing surfaces. Readings are taken directly from the handle – the 7-segment LCD has a resolution of 0.1 °C, its accuracy is ±1% or 1°C, whichever is greater, and it runs on a CR 2032 battery.
At the input, there is a Pt100 in 3-wire circuit in classes A, B, and AA, or alternatively a Type K thermocouple. The maximum range extends from -50 ... +400 °C with a smallest span of 50 K. The output is either the resistance directly on the connector or 4 ... 20 mA with HART in the 2-wire loop; the total accuracy via HART is 0.3% of the range at 16 bit. The transmitter is supplied from the current loop with 10 ... 35 VDC.
Please note before ordering: The sensor ranges up to +400 °C, but the factory setting of the transmitter only goes up to +200 °C; if you want to measure higher, you must specify the configuration as custom. The ambient temperature is not the medium temperature: With the transmitter, -20 ... +80 °C is permissible, without the transmitter -30 ... +100 °C, the medium may have -50 ... +400 °C. Supply and burden formula do not match: 10 ... 35 VDC are specified, but the burden formula calculates with UB - 12 V and results in a negative value below 12 V; sister sheets consistently state 12 ... 40 VDC. The lifespan of the CR 2032 battery and information on battery regulations are available on request. We will confirm the suitability of the handheld lance for process pressure on request. Super Seal and Deutsch DT04 three-pole only lead one sensor. Configuration is done using the HART interface with USB and software (01310-00220). A declaration of conformity is available on request. Explosion protection is not documented in the data sheet.
Advantages at a Glance
- Handheld lance Ø 10 mm in 500 to 2000 mm length – no installation required
- Pt100 in 3-wire circuit or Type K thermocouple
- Medium -50 ... +400 °C, accuracy 0.3% of range at 16 bit
- 4 ... 20 mA with HART or resistance directly on the connector
- Display on handle with 0.1 °C resolution, CR 2032 battery
- Lance made of stainless steel 1.4571, IP 65 / IP 68