EALB Junction box, ABS, for up to 8 load cells

  • Protection: IP67

Version: Equalization, up to 4 load cells, cable glands (EALB-01)
Price:
Sale price$86.00 USD

Net, excl. shipping

Questions about this product? +43 676 362 8453 office@octogon.org

Delivery Time & Shipping

Not the right fit? No problem. We build everything! Just ask.

Description

The EALB is a junction box made of ABS with a transparent lid and protection rating IP67. It brings together the cables of up to four load cells – up to eight in versions EALB-03 and EALB-04 – and passes one common signal on to the amplifier or indicator.

Versions

  • EALB-01 – equalization board, up to 4 load cells, 4 + 1 cable glands M16 × 1.5
  • EALB-02 – equalization board, up to 4 load cells, 4 + 1 PVC connections per cable sheath
  • EALB-03 – equalization board, up to 8 load cells, 8 + 2 cable glands M16 × 1.5, surge protection
  • EALB-04 – equalization board, up to 8 load cells, 8 + 2 PVC connections per cable sheath, surge protection
  • EALB-05 – parallel connection board, up to 4 load cells
  • EALB-06 – parallel connection board, up to 4 load cells, 4 + 1 cable glands M16 × 1.5
  • EALB-07 – parallel connection board, up to 4 load cells, 4 + 1 PVC connections per cable sheath

Features

  • ABS case with transparent lid, protection rating IP67
  • Operating temperature −20 … +60 °C
  • For load cells with 4 or 6 wires
  • Polyamide cable glands with plugs or PVC connections per cable sheath
  • Equalization boards with one 50 Ω potentiometer per load cell and test points for the adjustment
  • Protection against lightning and electrical discharges on EALB-03 and EALB-04
  • Shielded cable to the instrument, at least 4 × 0.5 mm² (4 wires) or 6 × 0.2 mm² (6 wires)

Equalization or parallel connection

The potentiometers of the equalization board are used to match the signals of the individual load cells. This requires that the sensitivities of the load cells differ by no more than 0.1 mV at 2 mV/V or 0.15 mV at 3 mV/V. The parallel connection board (EALB-05 to EALB-07) connects the load cells without adjustment.

Dimensions

The dimension drawing shows the case at 180 × 130 × 35 mm with four Ø 4.5 mm mounting holes at 163 × 113 mm. Details of the case for the eight-load-cell versions and of the cable entries of EALB-05 are available on request.

Terminal layout and dimension drawing are in the datasheet; the datasheet (DE/EN) and 3D data (STEP) are under Downloads. We are happy to help you choose the right version for your scale – contact us.