LKLE compression load cell

  • Rated load: 1,000 kg – 5,000 kg / 10 kN – 50 kN
  • Protection: IP68
  • Material: Stainless Steel AISI 420
  • Output: mV/V

Rated load: 1,000 kg
Price:
Sale price$370.00 USD

Net, excl. shipping

Questions about this product? +43 676 362 8453 office@octogon.org

Delivery Time & Shipping

Not the right fit? No problem. We build everything! Just ask.

Description

The LKLE is a low-profile compression load cell made of AISI 420 stainless steel with an integrated stainless steel base plate, for rated capacities of 1,000, 2,000 and 5,000 kg (10, 20 and 50 kN). Compression load cells are also called compression force transducers.

Typical applications

  • Weighing and force measurement in compression where installation height is limited
  • Installation with the matching weighing modules, which limit lateral movement, protect against tipping and compensate height

Benefits at a glance

  • Rated capacities 1,000, 2,000 and 5,000 kg (10, 20 and 50 kN)
  • Combined error no more than ± 0.03 % of the rated capacity
  • Rated output 2 mV/V ± 0.4 %
  • AISI 420 stainless steel with integrated base plate, protection rating IP68
  • Manufactured according to OIML R60
  • 10 m cable, six-wire technique

Mechanics and environment

The load cell withstands a safe overload of 150 % and a breaking load of 250 % of the rated capacity. The base plate measures 150 × 150 mm and has four holes Ø 14 mm at a spacing of 115 mm. The load is applied via a thread: M12 × 1.75 for 1,000 and 2,000 kg, M20 × 2.5 for 5,000 kg. The compensated temperature range is −10 … +50 °C, the operating temperature −20 … +70 °C.

Connection

Wheatstone full bridge in six-wire technique, excitation voltage no more than 15 V. Wire colours: excitation + red, sense + blue, excitation − black, sense − yellow, signal + green, signal − white.

Accessories and options

  • Weighing modules LMLAQ and LMLAP for 2,000 kg, LMLAN, LMLAL and LMLAK for 5,000 kg
  • Calibration report on request
  • Calibration by a laboratory accredited to ISO/IEC 17025 on request
  • Version for potentially explosive atmospheres, ATEX (zone 2-22), on request

Frequently asked questions

How does the LKLE differ from the LKLD? The LKLE has a base plate, is protected to IP68 and, with a combined error of no more than ± 0.03 %, is considerably more accurate. The LKLD is much smaller (Ø 32 or 38 mm) and covers 200 to 2,500 kg.

Do I need a measuring amplifier? Yes. The LKLE supplies an mV/V signal that is evaluated by a measuring amplifier or weighing transmitter.

Conformity: CE, RoHS and REACH. A declaration of conformity is available on request.