{"product_id":"ekmb-temperaturtransmitter-fuer-thermoelemente","title":"EKMB Thermocouple temperature transmitter","description":"\u003cp\u003eThe EKMB sits in the connection head and turns the voltage of a thermocouple into an impressed current of 4 to 20 mA. Eight thermocouple types are supported — K, S, R, J, T, N, B and E — and together they cover −260 to 1820 °C. The output is galvanically isolated against the input with 1 kV AC and is linearised in the device; the transmission error is at most 0.1 % of full scale or 0.2 °C, the resolution 16 bit. The device is supplied out of the current loop with 6 to 32 V DC and needs no auxiliary energy of its own. It is set without contact over RFID: type of thermocouple and measuring range can be changed at any time with the EKMH configurator and its software. The black PA66 case measures Ø 45 × 23 mm, weighs about 35 g and is rated IP20 for mounting inside the connection head.\u003c\/p\u003e\n\u003ch3\u003eInput and output\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eType K −260 … 1360 °C\u003c\/li\u003e\n\u003cli\u003eType S and R −40 … 1760 °C\u003c\/li\u003e\n\u003cli\u003eType J −200 … 1200 °C · Type B 40 … 1820 °C\u003c\/li\u003e\n\u003cli\u003eType T −260 … 400 °C · Type N −260 … 1280 °C\u003c\/li\u003e\n\u003cli\u003eType E −260 … 940 °C\u003c\/li\u003e\n\u003cli\u003eOutput 4 … 20 mA, isolated, linearised\u003c\/li\u003e\n\u003cli\u003eTransmission error max. 0.1 % FS or 0.2 °C\u003c\/li\u003e\n\u003cli\u003eIsolation voltage 1 kV AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDevice and connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupply 6 … 32 V DC out of the current loop\u003c\/li\u003e\n\u003cli\u003eConfiguration over RFID (NFC)\u003c\/li\u003e\n\u003cli\u003eCase synthetics PA66, black\u003c\/li\u003e\n\u003cli\u003eDimensions Ø 45 × 23 mm, approx. 35 g\u003c\/li\u003e\n\u003cli\u003eTerminal screws, conductor to 1 mm²\u003c\/li\u003e\n\u003cli\u003eProtection class IP20\u003c\/li\u003e\n\u003cli\u003eOperating temperature −40 … 85 °C\u003c\/li\u003e\n\u003cli\u003eEN 61000-6-4 and EN 61000-6-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll technical data, dimensions and available versions are listed in the datasheet for download.\u003c\/p\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57504502448454,"sku":"EKMB","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/EKMB_produkt.webp?v=1790930593","url":"https:\/\/octogon.org\/en\/products\/ekmb-thermocouple-temperature-transmitter","provider":"octogon GmbH","version":"1.0","type":"link"}