{"title":"Weight transmitters for load cells and force transducers","description":"\u003cp\u003e\u003cstrong\u003eWeight transmitters for load cells and force transducers\u003c\/strong\u003e convert the mV\/V signal of a load cell or force transducer into a format your control system can work with: 4…20 mA, 0…10 V, Modbus RTU via RS485, PROFINET, EtherCAT or IO-Link. Versions for DIN rail mounting, single- and multi-channel, with relay outputs for dosing and filling processes. Our range also includes models with PL (Performance Level) and SIL (Safety Integrity Level) approval. Price, data sheet and CAD model are online for every item.\u003c\/p\u003e\n\u003ch2\u003eChoosing weight transmitters for load cells and force transducers\u003c\/h2\u003e\n\u003ch3 dir=\"ltr\"\u003eTransmitter, indicator or measuring amplifier?\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eAll three types of device connect to the same load cell, but they serve different purposes. The terms are used interchangeably on the market, so here is the distinction as we use it in the shop:\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eA \u003cstrong\u003eweight transmitter\u003c\/strong\u003e, also called a signal converter or weighing amplifier, sits on the DIN rail in the control cabinet and has one job: getting the weight into the control system. The small display is for commissioning and diagnostics, not for the operator. It is the right choice when the plant evaluates the scale automatically.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eA \u003ca href=\"\/en\/collections\/waegeindikatoren\"\u003eweighing indicator\u003c\/a\u003e is built for people: large display, keypad, housing or panel mounting, functions such as tare, totalizing and ticket printing. You need one when someone has to read the value and operate the device.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eA \u003ca href=\"\/en\/collections\/dms-messverstaerker\"\u003estrain gauge amplifier\u003c\/a\u003e is designed for measurement engineering, not for weighing: high bandwidth, several channels, data logging. The choice for test rigs and laboratories, where the force curve matters rather than the final value.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eWhich interface suits your control system?\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eAnalog, 4…20 mA or 0…10 V\u003c\/strong\u003e, is the simplest solution if the PLC has a free analog card and only one value has to be transmitted. Keep in mind that the actual resolution is determined by your input card, not by the transmitter. A 16-bit output is of no use if it meets a 12-bit input. For noise immunity over longer cables, 4…20 mA is preferable to the voltage version.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModbus RTU via RS485\u003c\/strong\u003e uses no analog input and transmits more than just the weight: status, raw signal, tare values, error messages – and you can trigger zeroing and taring from the control system. A bus also lets you run many devices on one line, which considerably reduces wiring when there are several weighing points.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003ePROFINET and EtherCAT\u003c\/strong\u003e are the obvious choice if your plant already runs on that fieldbus. You get cyclic data at a defined update rate and diagnostics in your usual engineering tool. Details of the supported protocols can be found on our page on \u003ca href=\"\/en\/pages\/profinet\"\u003efieldbuses\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eIO-Link\u003c\/strong\u003e is the low-cost digital option at sensor level: device-level parameterization, tool changes without readjustment and no analog wiring. It makes sense for simple weighing points and wherever you connect many similar points. More on this under \u003ca href=\"\/en\/pages\/io-link\"\u003eIO-Link\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eSpeed and filters\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThe update rate decides whether a transmitter is suitable for your process. For a vessel level display, a few measurements per second are enough. For dosing, filling with in-flight correction or checkweighing in cycle, you need short response times, otherwise your control switches off too late.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe relationship is inconvenient but unavoidable: filters steady the display and cost response time. With oscillating loads, agitators and vibration you will have to filter, and the cut-off threshold then needs more lead time. Devices with an adjustable filter stage and several selectable rates give you room to maneuver during commissioning.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eOne channel or several?\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eFor a weighing point with several cells, the signals are traditionally combined in a junction box and evaluated by a \u003ca href=\"\/en\/collections\/waegetransmitter-1-kanal\"\u003esingle-channel transmitter\u003c\/a\u003e. This is the least expensive option and the right one for most tank and platform scales.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eA \u003ca href=\"\/en\/collections\/waegetransmitter-mehr-kanal\"\u003emulti-channel device\u003c\/a\u003e reads each cell individually. The advantage shows in operation: you can see which cell is drifting or defective, adjust the corner load deviation electronically instead of mechanically, and see on silos whether the load is unevenly distributed. With several separate weighing points in one plant, you also save devices and cabinet space.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eCommissioning\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eThere are two routes to a calibrated scale. \u003cstrong\u003eTheoretical calibration\u003c\/strong\u003e uses the rated load and the sensitivity in mV\/V of the cells from the data sheet, and the device calculates the scaling from these. A weighing point is ready for operation in minutes without test weights, which for large silos is often the only practical option. \u003cstrong\u003eReal calibration\u003c\/strong\u003e with test weights is more accurate because it takes installation effects into account, and it is required for legal-for-trade applications anyway.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eIf the plant is to be operated as legal for trade, the evaluation electronics must be suitable for this as well, not just the load cell. Talk this through with us before you choose. For the cells themselves, we calibrate \u003ca href=\"\/en\/pages\/kalibrierung-waegezelle-kraftmessdose-kraftaufnehmer-iso17025\"\u003eto ISO 17025\u003c\/a\u003e in our own laboratory.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eOther functions that count in the process\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eRelay outputs with adjustable setpoints handle coarse and fine flow during dosing, or the overload alarm, without the PLC having to intervene. Digital inputs take over zeroing and taring from an operator panel. For reading from a distance, combine the transmitter with a \u003ca href=\"\/en\/collections\/grossanzeigen\"\u003elarge display\u003c\/a\u003e; for mobile use there are \u003ca href=\"\/en\/collections\/funk-messtechnik\"\u003ewireless systems\u003c\/a\u003e and \u003ca href=\"\/en\/collections\/handheld-messgeraete\"\u003ehandheld devices\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eYou will find the matching sensors under \u003ca href=\"\/en\/collections\/waegezellen-kraftaufnehmer\"\u003eload cells and force transducers\u003c\/a\u003e, and the rest of the range under \u003ca href=\"\/en\/collections\/messelektronik\"\u003emeasuring electronics\u003c\/a\u003e. Our engineers will advise you directly on choosing the interface, number of channels and sampling rate.\u003c\/p\u003e","products":[{"product_id":"etlh-waegetransmitter","title":"ETLH weight transmitter","description":"\u003cp\u003e\u003cstrong\u003eWeight transmitter L-TLB4\u003c\/strong\u003e with 6-digit red LED display (8 mm digit height). Compact design with space-saving, slim construction. 4 buttons for system calibration. 6 display LEDs. Dimensions: 26 x 115 x 120 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4 independent readout channels for load cells\u003c\/strong\u003e (monitoring of individual load cells, total weight display, digital equalization).\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures of the L-TLB4 weight transmitter\u003cbr\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e✅16 bit analog output: 0\/4-20 mA; 0-5\/10V; ±5\/10V\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✅Interface RS485 (Modbus RTU\/ protocol ASCII). \u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e✅2 digital inputs, 3 relay outputs\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✅OIML R76:2006 certified, class III, 10000 counts 0.2μV\/VSI\u003c\/p\u003e\n\u003cp\u003e✅Installation on the rear wall or panel front on Omega\/DIN rail\u003c\/p\u003e\n\u003cp\u003e✅A\/D converter 24 bit 4 channels (16000000 digits) 4.8 kHz\u003c\/p\u003e\n\u003cp\u003e✅Counter steps 999999\u003c\/p\u003e\n\u003cp\u003e✅Fieldbuses: \u003cstrong\u003eRS485, CANopen, CC-Link, PROFIBUS, PROFINET, Ethernet\/IP, ETHERCAT\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅The analog output enables the output of:\u003cbr\u003e Current signal: 0...20 mA; 4...20 mA (up to 300 Ohm)\u003cbr\u003e Voltage signal: 0...10 V; 0...5V; ±10V; ±5 V (min 10k Ohm)\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca title=\"octogon Shop\" style=\"color: #d84f1b;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/L-TLB4_Datenblatt.pdf?v=1711463052\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCAD model:\u003cbr\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TLB4.stp?v=1712652135\" style=\"color: #d84f1b;\" title=\"octogon Shop\" target=\"_blank\"\u003eL-TLB4\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"octogon Shop","offers":[{"title":"4...20mA; 0...10V; ±10V","offer_id":49294290190662,"sku":"","price":253.0,"currency_code":"EUR","in_stock":true},{"title":"Profinet","offer_id":49294290223430,"sku":"","price":484.0,"currency_code":"EUR","in_stock":true},{"title":"EtherCAT","offer_id":49294290256198,"sku":"","price":484.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/waegetransmitter_L-TLB4.png?v=1735811016"},{"product_id":"etlg-waegetransmitter-analog-und-profinet-io","title":"ETLG weight transmitter, analog and ProfiNet-IO","description":"\u003cp\u003e\u003cstrong\u003eWeight transmitters\u003c\/strong\u003e with \u003cstrong\u003eanalog and ProfiNet-IO\u003c\/strong\u003e output serve as the interface between the \u003cstrong\u003eload cell\u003c\/strong\u003e, \u003cstrong\u003eweighing platform\u003c\/strong\u003e or other \u003cstrong\u003estrain gauge sensors\u003c\/strong\u003e and a \u003cstrong\u003ePLC unit \u003c\/strong\u003ein industrial applications. Weight transmitter indicator with 6-digit red LED display (8 mm digit height). Compact design with space-saving narrow construction.  4 buttons for system calibration. 6 indicator LEDs. Dimensions: 25 x 115 x 120 mm.\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures of the weight transmitters\u003cbr\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e✅Weight transmitter for mounting on the rear wall of the control panel on\u003cbr\u003eOmega\/DIN rail\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✅6-digit semi-alphanumeric red LED display\u003cbr\u003e(8 mm digit height)\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e✅RS485 serial interface for communication via\u003cbr\u003eModBus RTU, ASCII or continuous unidirectional\u003cbr\u003etransmission protocols\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✅3 relay outputs controlled by setpoints or via protocols\u003c\/p\u003e\n\u003cp\u003e✅2 opto-isolated digital PNP inputs: status readout via serial\u003cbr\u003ecommunication protocols\u003c\/p\u003e\n\u003cp\u003e✅1 load cell input\u003c\/p\u003e\n\u003cp\u003e✅The analog output provides:\u003cbr\u003eCurrent signal: 0...20 mA; 4...20 mA (up to 300 ohm)\u003cbr\u003eVoltage signal: 0...10 V; 0...5 V; ±10 V; ±5 V (min. 10k ohm)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/L-TLB_Datenblatt.pdf?v=1711463053\" style=\"color: #d84f1b;\" title=\"octogon Shop\" rel=\"noopener\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCAD model:\u003cbr\u003e\u003ca rel=\"noopener\" title=\"octogon Shop\" style=\"color: #d84f1b;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TLB.stp?v=1712652129\" target=\"_blank\"\u003e3D data\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"octogon Shop","offers":[{"title":"4...20mA; 0...10V; ±10V","offer_id":49312646660422,"sku":"","price":220.0,"currency_code":"EUR","in_stock":true},{"title":"Profinet","offer_id":49312646693190,"sku":"","price":418.0,"currency_code":"EUR","in_stock":true},{"title":"EtherCAT","offer_id":49312646725958,"sku":"","price":451.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/ETLG_TLB__product_freigestellt.png?v=1786622909"},{"product_id":"etla-analoger-waegetransmitter","title":"ETLA analog weight transmitter","description":"\u003cp\u003e\u003cstrong\u003eAnalog weight transmitter L-TLE (RS485)\u003c\/strong\u003e for installation on the rear wall of the control panel on Omega\/DIN rail or in the box (on request) and with backlit LCD display, 38x16 mm, 2 lines of 8 digits (5 mm digit height). Suitable for applications requiring a \u003cstrong\u003efast response time\u003c\/strong\u003e \u003cstrong\u003eof the analog output\u003c\/strong\u003e (update time 0.003...4 sec. \/ 10...30 Hz). Dimensions: 90x95x60 mm. 3-position selector, DIP switch and rotary knob.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures of the L-TLE Analog Weight Transmitter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e✅Serial \u003cstrong\u003einterface RS485\u003c\/strong\u003e for communication via \u003cstrong\u003eModBus RTU\u003c\/strong\u003e protocols\u003c\/p\u003e\n\u003cp\u003e✅Easy adjustment of zero point and full scale without multimeter, but by digital rotary control (encoder)\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e✅4 load cell inputs\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✅ \u003cstrong\u003e16 bit\u003c\/strong\u003e \u003cstrong\u003efast\u003c\/strong\u003e \u003cstrong\u003eanalog output\u003c\/strong\u003e in current or voltage: 0...20 mA, 4...20 mA; 0...10 V, 0...5 V; ±10 V, ±5 V; response time: 3 ms)\u003c\/p\u003e\n\u003cp\u003e✅Connections to: PLC via analog output, PC\/PLC via RS485 (up to 99 instruments with amplifiers, up to 32 without amplifiers), up to 8 load cells in parallel with junction box\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✅Simultaneous display of the load cell response signal expressed in mV and the value of the analog output\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca title=\"octogon Shop\" style=\"color: #d84f1b;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/L-TLE_Datenblatt.pdf?v=1711463052\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCAD model:\u003cbr\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TLE.stp?v=1712652139\" style=\"color: #d84f1b;\" title=\"octogon Shop\" target=\"_blank\"\u003eL-TLE CAD model\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":49310775411014,"sku":"","price":182.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/waegetransmitter_L-TLE.png?v=1713431511"},{"product_id":"etlb-intelligenter-anschlusskasten","title":"ETLB smart junction box","description":"\u003cp\u003eThe \u003cstrong\u003eETLB\u003c\/strong\u003e is an intelligent junction box with \u003cstrong\u003e8 independent channels\u003c\/strong\u003e for load cells, type \u003cstrong\u003eCLM8\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is designed for weighing systems where each connected load cell is to be monitored individually, for example, in the direct control of a weighbridge.\u003c\/p\u003e\n\u003cp\u003eThe A\/D converter operates with \u003cstrong\u003e8 channels\u003c\/strong\u003e, \u003cstrong\u003e24 bits\u003c\/strong\u003e, and \u003cstrong\u003e16,000,000 digits\u003c\/strong\u003e at \u003cstrong\u003e4.8 kHz\u003c\/strong\u003e, providing \u003cstrong\u003e600 conversions per second\u003c\/strong\u003e. \u003cstrong\u003eUp to 16 load cells with 350 Ω\u003c\/strong\u003e can be connected in 4- or 6-wire technology; the measuring range is \u003cstrong\u003e±39 mV\u003c\/strong\u003e with a sensitivity of \u003cstrong\u003e±7 mV\/V\u003c\/strong\u003e. Linearity is \u003cstrong\u003e\u0026lt; 0.01% full scale\u003c\/strong\u003e, and thermal drift is \u003cstrong\u003e\u0026lt; 0.0005% full scale\/°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe functional scope includes digital equalization of the 8 channels, load distribution analysis, and diagnosis for each load cell; an external inclinometer compensates for the inclination of the weighing system up to \u003cstrong\u003e±10 degrees\u003c\/strong\u003e. The device is operated via a backlit alphanumeric LCD with 2 lines of 8 characters (\u003cstrong\u003e5 mm\u003c\/strong\u003e digit height) and a 4-button keypad. Communication takes place via \u003cstrong\u003eRS485 and RS232\u003c\/strong\u003e with \u003cstrong\u003eModBus RTU\u003c\/strong\u003e, ASCII, or continuous transmission. Power supply is from \u003cstrong\u003e12 to 24 V DC\u003c\/strong\u003e at \u003cstrong\u003e5 W\u003c\/strong\u003e; the operating temperature range is from \u003cstrong\u003e-20 °C to +60 °C\u003c\/strong\u003e. Versions are available for Omega\/DIN rail, as a pure circuit board, and \u003cstrong\u003eIP67\u003c\/strong\u003e enclosures made of polycarbonate, ABS, or \u003cstrong\u003eAISI 304\u003c\/strong\u003e stainless steel. Certified according to \u003cstrong\u003eOIML R76:2006\u003c\/strong\u003e, Class III, with 3 x 10,000 verification intervals; UL-recognized component for USA and Canada.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003e8 independent load cell channels with individual monitoring\u003c\/li\u003e\n\n\u003cli\u003eDigital equalization, load distribution analysis, and automatic diagnosis\u003c\/li\u003e\n\n\u003cli\u003e24-bit A\/D converter, 16,000,000 digits, 600 conversions per second\u003c\/li\u003e\n\n\u003cli\u003eUp to 16 load cells with 350 Ω\u003c\/li\u003e\n\n\u003cli\u003eRS485 and RS232 with ModBus RTU, Ethernet TCP\/IP on request\u003c\/li\u003e\n\n\u003cli\u003eInclination compensation up to ±10 degrees via inclinometer\u003c\/li\u003e\n\n\u003cli\u003eIP67 enclosure made of polycarbonate, ABS, or AISI 304 stainless steel\u003c\/li\u003e\n\n\u003cli\u003eOIML R76:2006, Class III, 3 x 10,000 verification intervals\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":56812564873542,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/ETLB_CLM8_titelbild.png?v=1788184596"},{"product_id":"etld-digitaler-transmitter-und-lastbegrenzer","title":"ETLD digital transmitter and load limiter","description":"\u003cp\u003eThe \u003cstrong\u003eETLD\u003c\/strong\u003e is a digital transmitter and load limiter for lifting systems, type \u003cstrong\u003eL-LCD3\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt detects load limitation by triggering alarm and pre-alarm thresholds and covers systems with up to 4 weighing points by combining several units.\u003c\/p\u003e\n\u003cp\u003eInstallation is on the rear panel of the control cabinet on Omega\/DIN rail or in a box; dimensions are \u003cstrong\u003e140 x 93 x 65 mm\u003c\/strong\u003e including the terminal block. Setup and calibration are done via a 4-button keypad and an LCD display with 2 lines of 16 characters (\u003cstrong\u003e5 mm\u003c\/strong\u003e digit height). LED indicators show the status of the relay outputs, and a faulty load cell connection is reported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUp to 8 load cells with 350 Ω\u003c\/strong\u003e can be connected with a supply of \u003cstrong\u003e4 V DC\u003c\/strong\u003e. The A\/D converter operates at \u003cstrong\u003e24 bit\u003c\/strong\u003e and \u003cstrong\u003e3 conversions per second\u003c\/strong\u003e, the measuring range is \u003cstrong\u003e±3.9 mV\u003c\/strong\u003e, linearity is \u003cstrong\u003e\u0026lt; 0.01 % full scale\u003c\/strong\u003e, and thermal drift is \u003cstrong\u003e\u0026lt; 0.002 % full scale\/°C\u003c\/strong\u003e. Power supply is \u003cstrong\u003e24 to 48 V DC\/VAC\u003c\/strong\u003e at \u003cstrong\u003e6 VA\u003c\/strong\u003e, and the operating temperature range is \u003cstrong\u003e-10 °C to +50 °C\u003c\/strong\u003e. \u003cstrong\u003eRS485 and RS232\u003c\/strong\u003e with ASCII protocol, as well as 2 digital inputs, are available for communication. The \u003cstrong\u003eL-LCD3\u003c\/strong\u003e version has \u003cstrong\u003e3 relay outputs\u003c\/strong\u003e and one load cell input; an integrated RF interface for combining multiple units is available on request. The \u003cstrong\u003eL-LCD3PL\u003c\/strong\u003e variant offers \u003cstrong\u003e2 independent load cell inputs\u003c\/strong\u003e and \u003cstrong\u003e4 relay outputs\u003c\/strong\u003e with guided safety contact and meets Category 2 according to \u003cstrong\u003eEN 13849-1:2008, PL d\u003c\/strong\u003e (equivalent to SIL 2 according to EN 62061).\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eDigital transmitter and load limiter for lifting systems\u003c\/li\u003e\n\n\u003cli\u003eLoad limitation via alarm and pre-alarm thresholds\u003c\/li\u003e\n\n\u003cli\u003eSystems with up to 4 weighing points by combining multiple units\u003c\/li\u003e\n\n\u003cli\u003eUp to 8 load cells with 350 Ω, measuring range ±3.9 mV\u003c\/li\u003e\n\n\u003cli\u003eInstallation on Omega\/DIN rail, 140 x 93 x 65 mm\u003c\/li\u003e\n\n\u003cli\u003eRS485 and RS232 with ASCII protocol, RF interface on request\u003c\/li\u003e\n\n\u003cli\u003eL-LCD3PL variant with dual load cell input, Category 2 according to EN 13849-1:2008, PL d\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":56812564906310,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/ETLD_L-LCD3PL_titelbild.png?v=1788184595"},{"product_id":"etle-analoger-waegetransmitter-4-20-ma-oder-0-10-v-ip67-gehaeuse","title":"ETLE analog weight transmitter, 4–20 mA or 0–10 V, IP67 enclosure","description":"\u003cp\u003eThe \u003cstrong\u003eETLE\u003c\/strong\u003e is an analog weighing transmitter with a \u003cstrong\u003e4–20 mA or 0–10 V\u003c\/strong\u003e output.\u003c\/p\u003e\n\u003cp\u003eIt transmits the signal from tension and compression load cells as an analog signal to a controller and is compatible with standard analog\/digital PLC cards.\u003c\/p\u003e\n\u003cp\u003eThe transmitter has its own load cell input and, via a junction box, can accommodate \u003cstrong\u003eup to 4 load cells at 350 Ω\u003c\/strong\u003e in 4- or 6-wire technology; the load cell excitation is \u003cstrong\u003e5 V DC\/60 mA\u003c\/strong\u003e. The measuring range is \u003cstrong\u003e1 to 3 mV\/V\u003c\/strong\u003e, linearity is \u003cstrong\u003e0.01% full scale\u003c\/strong\u003e, and thermal drift is \u003cstrong\u003e0.005% full scale\/°C\u003c\/strong\u003e. The analog output provides \u003cstrong\u003e4 to 20 mA\u003c\/strong\u003e (max. 300 Ω) or \u003cstrong\u003e0 to 10 V DC\u003c\/strong\u003e (min. 10 kΩ).\u003c\/p\u003e\n\u003cp\u003eZero point and full scale are adjusted via 12-turn potentiometers, and sensitivity is set via 3 DIP switches; two additional DIP switches select between unidirectional (tension or compression) and bidirectional (tension and compression) operation. Calibration is performed using calibration weights or a load cell simulator. Power supply is \u003cstrong\u003e12 to 24 V DC\u003c\/strong\u003e at \u003cstrong\u003e2 W\u003c\/strong\u003e, the operating temperature range is from \u003cstrong\u003e-20 °C to +60 °C\u003c\/strong\u003e, and the storage temperature is from \u003cstrong\u003e-30 °C to +80 °C\u003c\/strong\u003e. The bare circuit board measures \u003cstrong\u003e45 x 26 x 11 mm\u003c\/strong\u003e, while the version in an \u003cstrong\u003eIP67\u003c\/strong\u003e ABS housing with two M12x1.5 cable glands measures \u003cstrong\u003e94 x 53 x 40 mm\u003c\/strong\u003e. A circular circuit board with \u003cstrong\u003eØ 20 mm\u003c\/strong\u003e and 8 mm height with solder terminals is available upon request.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eAnalog weighing transmitter for tension and compression load cells\u003c\/li\u003e\n\n\u003cli\u003eAnalog output 4 to 20 mA or 0 to 10 V DC\u003c\/li\u003e\n\n\u003cli\u003eUp to 4 load cells at 350 Ω via junction box\u003c\/li\u003e\n\n\u003cli\u003eMeasuring range 1 to 3 mV\/V, linearity 0.01% full scale\u003c\/li\u003e\n\n\u003cli\u003e45 x 26 x 11 mm circuit board for compact installation\u003c\/li\u003e\n\n\u003cli\u003eIP67 ABS housing with two M12x1.5 cable glands\u003c\/li\u003e\n\n\u003cli\u003eAdjustment via 12-turn potentiometers and DIP switches\u003c\/li\u003e\n\n\u003cli\u003eOptionally available as a circular circuit board with Ø 20 mm\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":56812564939078,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/ETLE_L-TLC_titelbild.png?v=1788184595"},{"product_id":"etlf-waegetransmitter-24-bit-rs485-mit-modbus-rtu","title":"ETLF weight transmitter, 24 bit, RS485 with ModBus RTU","description":"\u003cp\u003eThe \u003cstrong\u003eETLF\u003c\/strong\u003e is a weighing transmitter for mounting on the back panel of the control cabinet on an Omega\/DIN rail, type \u003cstrong\u003eTLS\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt provides the weight value analogously to a PLC or digitally via RS485 to a PC, controller, and remote display.\u003c\/p\u003e\n\u003cp\u003eThe device has \u003cstrong\u003e4 load cell inputs\u003c\/strong\u003e and processes \u003cstrong\u003eup to 8 load cells with 350 Ω\u003c\/strong\u003e via a junction box with a supply of \u003cstrong\u003e5 V DC\/120 mA\u003c\/strong\u003e. The A\/D converter operates with \u003cstrong\u003e24 bits\u003c\/strong\u003e and \u003cstrong\u003e16,000,000 digits\u003c\/strong\u003e and delivers \u003cstrong\u003e80 conversions per second\u003c\/strong\u003e. The measuring range is \u003cstrong\u003e±19.5 mV\u003c\/strong\u003e, the sensitivity of the load cells is \u003cstrong\u003e±3 mV\/V\u003c\/strong\u003e, linearity is \u003cstrong\u003e\u0026lt; 0.01% full scale\u003c\/strong\u003e, and thermal drift is \u003cstrong\u003e\u0026lt; 0.0005% full scale\/°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe opto-isolated analog output operates with \u003cstrong\u003e16 bits\u003c\/strong\u003e and delivers \u003cstrong\u003e0 to 20 mA\u003c\/strong\u003e or \u003cstrong\u003e4 to 20 mA\u003c\/strong\u003e (up to 300 Ω) or \u003cstrong\u003e0 to 10 V\u003c\/strong\u003e (min. 10 kΩ). In addition, there are \u003cstrong\u003e2 opto-relay outputs\u003c\/strong\u003e, \u003cstrong\u003e2 opto-isolated digital PNP inputs\u003c\/strong\u003e, and \u003cstrong\u003eRS485\u003c\/strong\u003e with \u003cstrong\u003eModBus RTU\u003c\/strong\u003e, ASCII, or continuous transmission. The 6-digit semi-alphanumeric red LED display has a digit height of \u003cstrong\u003e8 mm\u003c\/strong\u003e; the instrument is configured with the free PC software Instrument Manager. The housing measures \u003cstrong\u003e123 x 92 x 50 mm\u003c\/strong\u003e, the power supply is \u003cstrong\u003e12 to 24 V DC\u003c\/strong\u003e at \u003cstrong\u003e5 W\u003c\/strong\u003e, and the operating temperature range is from \u003cstrong\u003e-20 °C to +60 °C\u003c\/strong\u003e. Upon request, an \u003cstrong\u003eIP67\u003c\/strong\u003e polycarbonate enclosure and an \u003cstrong\u003eATEX II 3GD\u003c\/strong\u003e version for Zone 2-22 are available; the device is a UL-recognized component for the USA and Canada.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eWeighing transmitter for Omega\/DIN rail, 123 x 92 x 50 mm\u003c\/li\u003e\n\n\u003cli\u003eUp to 8 load cells with 350 Ω via junction box\u003c\/li\u003e\n\n\u003cli\u003eA\/D converter 24 bits, 16,000,000 digits, 80 conversions per second\u003c\/li\u003e\n\n\u003cli\u003eOpto-isolated analog output with 16 bits in current or voltage\u003c\/li\u003e\n\n\u003cli\u003eRS485 with ModBus RTU, ASCII or continuous transmission\u003c\/li\u003e\n\n\u003cli\u003eIP67 enclosure and ATEX II 3GD version for Zone 2-22 upon request\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":56812564971846,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/ETLF_TLS_titelbild.png?v=1788184595"},{"product_id":"esma-dms-bruecken-messverstaerker-sil3","title":"ESMA strain gauge bridge amplifier, SIL3","description":"\u003cp\u003e\u003cstrong\u003eStrain gauge bridge amplifier SMM-DR\u003c\/strong\u003e for safety-related force and load measurement rated \u003cstrong\u003eSIL3\u003c\/strong\u003e and \u003cstrong\u003ePL e category 3\u003c\/strong\u003e. The amplifier puts \u003cstrong\u003eone\u003c\/strong\u003e bridge signal on \u003cstrong\u003etwo galvanically isolated current outputs\u003c\/strong\u003e, so that a safety controller can check the two channels against each other.\u003c\/p\u003e\n\u003cp\u003eThis is a safety component, not a measuring instrument: the redundancy comes from the two outputs, not from higher measuring accuracy. If the channels deviate by more than 10 %, the controller takes the plant to its safe state.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003etest pulse input\u003c\/strong\u003e allows the measuring chain to be checked during operation: a 24 VDC pulse raises the current of channel B by 1 mA. The matching safety controller is the SCU-DR from the same range.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures of the SMM-DR\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e✅Sensor input: \u003cstrong\u003e1 × strain gauge full bridge 350 Ω\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Bridge sensitivity: up to \u003cstrong\u003e4 mV\/V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Bridge supply: 5 VDC\u003c\/p\u003e\n\u003cp\u003e✅Analog output: \u003cstrong\u003e2 × 4 … 20 mA\u003c\/strong\u003e, channel A and B, galvanically isolated\u003c\/p\u003e\n\u003cp\u003e✅Nominal range: 8 … 16 mA within 4 … 20 mA\u003c\/p\u003e\n\u003cp\u003e✅Load resistance: 500 Ω max.\u003c\/p\u003e\n\u003cp\u003e✅Test pulse input: 24 VDC ±20 %, ≤ 250 Hz\u003c\/p\u003e\n\u003cp\u003e✅Safety rating: \u003cstrong\u003eSIL3\u003c\/strong\u003e (EN 61508, EN 62061) · \u003cstrong\u003ePL e category 3\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Supply: 24 VDC ±10 %, 100 mA max.\u003c\/p\u003e\n\u003cp\u003e✅Housing: DR22.5 for TS 35 rail · 117.2 × 22.5 × 113.6 mm\u003c\/p\u003e\n\u003cp\u003e✅Protection: IP20\u003c\/p\u003e\n\u003cp\u003e✅Temperature coefficient: \u0026lt; 50 ppm\/K\u003c\/p\u003e\n\u003cp\u003e✅Order number: 0600-00492\u003c\/p\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57265729929542,"sku":null,"price":860.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/ESMA_SMM-DR__product.png?v=1788560250"},{"product_id":"esmb-dms-bruecken-messverstaerker-sil3-ip65","title":"ESMB strain gauge bridge amplifier, SIL3, IP65","description":"\u003cp\u003e\u003cstrong\u003eStrain gauge bridge amplifier SMM-HD\u003c\/strong\u003e for safety-related force and load measurement rated \u003cstrong\u003eSIL3\u003c\/strong\u003e and \u003cstrong\u003ePL e category 3\u003c\/strong\u003e — in an \u003cstrong\u003eIP65 field housing\u003c\/strong\u003e for mounting outside the control cabinet.\u003c\/p\u003e\n\u003cp\u003eEach bridge signal goes to \u003cstrong\u003etwo galvanically isolated current outputs\u003c\/strong\u003e, so that a safety controller can check the channels against each other. The device is a safety component, not a measuring instrument: the redundancy comes from the two outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOne or two amplifiers\u003c\/strong\u003e sit in the same housing — with two bridges, two measuring points are monitored safely and independently of each other. The matching safety controller is the SCU-DR from the same range.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures of the SMM-HD\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e✅Sensor input: \u003cstrong\u003e1 or 2 × strain gauge full bridge 350 Ω\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Bridge sensitivity: up to \u003cstrong\u003e4 mV\/V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Bridge supply: 5 VDC\u003c\/p\u003e\n\u003cp\u003e✅Analog output: \u003cstrong\u003e2 × 4 … 20 mA per bridge\u003c\/strong\u003e, galvanically isolated\u003c\/p\u003e\n\u003cp\u003e✅Nominal range: 8 … 16 mA within 4 … 20 mA\u003c\/p\u003e\n\u003cp\u003e✅Load resistance: 500 Ω max.\u003c\/p\u003e\n\u003cp\u003e✅Test pulse input included\u003c\/p\u003e\n\u003cp\u003e✅Safety rating: \u003cstrong\u003eSIL3\u003c\/strong\u003e (EN 61508, EN 62061) · \u003cstrong\u003ePL e category 3\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Supply: 24 VDC ±10 %, 100 mA max.\u003c\/p\u003e\n\u003cp\u003e✅Housing: U-CASE 2 field housing\u003c\/p\u003e\n\u003cp\u003e✅Protection: \u003cstrong\u003eIP65\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Order numbers: 0600-00493 (one bridge) · 0600-00494 (two bridges)\u003c\/p\u003e","brand":"octogon Shop","offers":[{"title":"A full bridge (0600-00493)","offer_id":57265731404102,"sku":null,"price":904.0,"currency_code":"EUR","in_stock":true},{"title":"Two full bridges (0600-00494)","offer_id":57265731535174,"sku":null,"price":1729.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/ESMB_SMM-HD__product.png?v=1788560313"},{"product_id":"esmc-dms-bruecken-messverstaerker-sil1-ip65","title":"ESMC strain gauge bridge amplifier, SIL1, IP65","description":"\u003cp\u003e\u003cstrong\u003eStrain gauge bridge amplifier SMM-HD-SIL1\u003c\/strong\u003e with a \u003cstrong\u003ebuilt-in safety circuit\u003c\/strong\u003e for \u003cstrong\u003eSIL1\u003c\/strong\u003e and \u003cstrong\u003ePL c\u003c\/strong\u003e — in an IP65 field housing for mounting outside the control cabinet.\u003c\/p\u003e\n\u003cp\u003eThe difference to the SIL3 range: the safety function sits \u003cstrong\u003einside the device\u003c\/strong\u003e. A second amplifier, two comparators and a semiconductor relay watch the bridge independently of the measuring channel. \u003cstrong\u003eNo safety controller is required\u003c\/strong\u003e — the device switches by itself.\u003c\/p\u003e\n\u003cp\u003eThat makes the SMM-HD-SIL1 a usable measuring amplifier at the same time: \u003cstrong\u003e0.1 % of range\u003c\/strong\u003e plus sensor error, 24 bit resolution, output either 4 … 20 mA or 0 … 10 V.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures of the SMM-HD-SIL1\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e✅Sensor input: \u003cstrong\u003e1 × strain gauge full bridge 350 Ω\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Bridge sensitivity: up to \u003cstrong\u003e4 mV\/V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Bridge supply: 1.25 … 3 VDC\u003c\/p\u003e\n\u003cp\u003e✅Analog output: \u003cstrong\u003e4 … 20 mA or 0 … 10 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Accuracy: \u003cstrong\u003e0.1 % of range\u003c\/strong\u003e plus sensor error\u003c\/p\u003e\n\u003cp\u003e✅Resolution: \u003cstrong\u003e24 bit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Switching output: 30 VAC\/VDC, 500 mA max.\u003c\/p\u003e\n\u003cp\u003e✅Response time: 50 ms\u003c\/p\u003e\n\u003cp\u003e✅Safety rating: \u003cstrong\u003eSIL1 · PL c — built in\u003c\/strong\u003e, no safety controller required\u003c\/p\u003e\n\u003cp\u003e✅Housing: U-CASE 2 field housing\u003c\/p\u003e\n\u003cp\u003e✅Protection: \u003cstrong\u003eIP65\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Order key: Q X X X X - X X\u003c\/p\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57265732190534,"sku":null,"price":452.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/ESMC_SMM-HD-SIL1__product.png?v=1788560365"},{"product_id":"esme-dms-bruecken-messverstaerker-sil1-hutschiene","title":"ESME strain gauge bridge amplifier, SIL1, DIN rail","description":"\u003cp\u003e\u003cstrong\u003eStrain gauge bridge amplifier SMM-DR-SIL1\u003c\/strong\u003e with a \u003cstrong\u003ebuilt-in safety circuit\u003c\/strong\u003e for \u003cstrong\u003eSIL1\u003c\/strong\u003e and \u003cstrong\u003ePL c\u003c\/strong\u003e — in a DR22.5 DIN rail housing for the control cabinet.\u003c\/p\u003e\n\u003cp\u003eThe safety function sits \u003cstrong\u003einside the device\u003c\/strong\u003e: a second amplifier, two comparators and a semiconductor relay watch the bridge independently of the measuring channel. \u003cstrong\u003eNo safety controller is required\u003c\/strong\u003e — that is the difference to the SIL3 range, which does require one.\u003c\/p\u003e\n\u003cp\u003eA usable measuring amplifier at the same time: \u003cstrong\u003e0.1 % of range\u003c\/strong\u003e plus sensor error, 24 bit resolution, output either 4 … 20 mA or 0 … 10 V. The identical version in an IP65 field housing is the SMM-HD-SIL1.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures of the SMM-DR-SIL1\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e✅Sensor input: \u003cstrong\u003e1 × strain gauge full bridge 350 Ω\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Bridge sensitivity: up to \u003cstrong\u003e4 mV\/V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Bridge supply: 1.25 … 3 VDC\u003c\/p\u003e\n\u003cp\u003e✅Analog output: \u003cstrong\u003e4 … 20 mA or 0 … 10 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Accuracy: \u003cstrong\u003e0.1 % of range\u003c\/strong\u003e plus sensor error\u003c\/p\u003e\n\u003cp\u003e✅Resolution: \u003cstrong\u003e24 bit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Switching output: 30 VAC\/VDC, 500 mA max.\u003c\/p\u003e\n\u003cp\u003e✅Response time: 50 ms\u003c\/p\u003e\n\u003cp\u003e✅Safety rating: \u003cstrong\u003eSIL1 · PL c — built in\u003c\/strong\u003e, no safety controller required\u003c\/p\u003e\n\u003cp\u003e✅Housing: DR22.5 for DIN rail\u003c\/p\u003e\n\u003cp\u003e✅Protection: IP20\u003c\/p\u003e\n\u003cp\u003e✅Order key: R A X X X - X X\u003c\/p\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57265732485446,"sku":null,"price":430.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/ESME_SMM-DR-SIL1__product.png?v=1788560461"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/collections\/Elektronik_-_Transmitter.png?v=1782471259","url":"https:\/\/octogon.org\/en\/collections\/weight-transmitters.oembed","provider":"octogon GmbH","version":"1.0","type":"link"}