{"title":"Temperature Sensors","description":"\u003ch2\u003eTemperature sensors and temperature probes\u003c\/h2\u003e \u003cp\u003eWe sort temperature probes by \u003cstrong\u003edesign\u003c\/strong\u003e, not by sensing element. The reason is a practical one: you know how the probe has to be installed – screwed in, laid against a surface, hung in a room – and many designs take either sensing element anyway, resistance thermometer as well as thermocouple.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003ca href=\"\/en\/collections\/temperatur-einschraub-te\"\u003eScrew-in probes\u003c\/a\u003e with a process connection, for measuring in the medium\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"\/en\/collections\/temperatur-magnetisch-tm\"\u003eMagnetic surface probes\u003c\/a\u003e and \u003ca href=\"\/en\/collections\/temperatur-feder-kontakt-ts\"\u003espring-loaded contact probes\u003c\/a\u003e for cases where no intervention in the process is possible\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"\/en\/collections\/temperatur-infrarot-ti\"\u003eInfrared sensors\u003c\/a\u003e for non-contact measurement on moving and very hot surfaces\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"\/en\/collections\/temperatur-raum-tr\"\u003eRoom probes\u003c\/a\u003e for cold rooms, air-conditioning and building services\u003c\/li\u003e \u003cli\u003e\n\u003ca href=\"\/en\/collections\/temperatur-funk-tf\"\u003eWireless probes\u003c\/a\u003e for measuring points no cable reaches\u003c\/li\u003e \u003c\/ul\u003e \u003ch3\u003eSignal and evaluation\u003c\/h3\u003e \u003cp\u003eSome of the probes already carry the transmitter in the terminal head and output \u003ca href=\"\/en\/collections\/temperatursensoren-analog\"\u003e4…20 mA\u003c\/a\u003e, often with a superimposed HART signal, plus a display and limit contacts on the device. Anyone who prefers a passive probe and a separate transmitter will find the transmitters under \u003ca href=\"\/en\/collections\/temperaturmessumformer\"\u003etemperature transmitters\u003c\/a\u003e.\u003c\/p\u003e \u003ch3\u003eHigh temperatures\u003c\/h3\u003e \u003cp\u003eFor applications beyond the usual range we supply sensors up to 600 °C. Background and selection criteria are on the page \u003ca href=\"\/en\/pages\/hochtemperatursensoren-bis-600-c\"\u003ehigh-temperature sensors\u003c\/a\u003e.\u003c\/p\u003e \u003cp\u003eThe range in the shop keeps growing – sheathed and cable probes, terminal-head versions, hand-held instruments, limit switches and marine versions to GL will follow over the coming weeks. If your design, measuring range or process connection is not there, please ask: \u003ca href=\"mailto:office@octogon.org\"\u003eoffice@octogon.org\u003c\/a\u003e or +43 676 3628453 – we also supply special designs.\u003c\/p\u003e","products":[{"product_id":"temf-kompakt-temperatursensor-mit-schiffszulassung","title":"TEMF compact temperature sensor with marine approval","description":"\u003cp\u003eThe \u003cstrong\u003eTEMF\u003c\/strong\u003e is a modular compact temperature sensor with marine approval, manufacturer type Müller \u003cstrong\u003eMKTS-GL\u003c\/strong\u003e; the intrinsically safe version is called \u003cstrong\u003eMKTS-GLEx\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIt measures directly in the medium, where high pressure and a harsh environment come together: \u003cstrong\u003e250 bar\u003c\/strong\u003e system pressure at \u003cstrong\u003e375 bar\u003c\/strong\u003e burst pressure; sensor tube, housing body and connector insert all in stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e – the connector insert included, no plastic –, protection class \u003cstrong\u003eIP 65\u003c\/strong\u003e at the electronics and \u003cstrong\u003eIP 68\u003c\/strong\u003e at the sensor. Added to this the type approvals \u003cstrong\u003eDNV TAA00003GS\u003c\/strong\u003e and \u003cstrong\u003eEU RO MRA0000052\u003c\/strong\u003e, which apply to both versions.\u003c\/p\u003e\u003cp\u003eOne datasheet covers two versions: they differ in the approval and in the operating temperature – and in nothing else. The \u003cstrong\u003eMKTS-GLEx\u003c\/strong\u003e is additionally intrinsically safe, \u003cstrong\u003eII 1 G Ex ia IIC T6..T1 Ga\u003c\/strong\u003e for zones 0, 1 and 2 with gases; the MKTS-GL has \u003cstrong\u003eno explosion protection\u003c\/strong\u003e. The order codes are identical field by field, only the identifier changes from MK to GN.\u003c\/p\u003e\u003cp\u003eMeasurement is made with \u003cstrong\u003eone or two Pt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e in 2-, 3- or 4-wire technology, in \u003cstrong\u003eclass A\u003c\/strong\u003e only, at 24-bit resolution. The measuring range runs from \u003cstrong\u003e-50 … +200 °C\u003c\/strong\u003e, the smallest span is \u003cstrong\u003e50 K\u003c\/strong\u003e. At the output, \u003cstrong\u003e4 … 20 mA\u003c\/strong\u003e, three voltage ranges or the resistance directly at the connector are available.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The accuracy of \u003cstrong\u003emax. 0.1 % of range\u003c\/strong\u003e applies only between 0 and +40 °C; below that, 0.0015 % per kelvin is added, above it 0.019 % – at +80 °C around 0.76 % on top, plus the error of the measuring element. Ambient temperature and medium temperature are two different things: the MKTS-GL works at \u003cstrong\u003e-40 … +85 °C\u003c\/strong\u003e, whereas for the MKTS-GLEx the limit depends on the temperature class and on the output type – current output -40 … +75 °C, voltage output only -40 … +50 °C, passive -50 … +100 °C. The medium temperature of the MKTS-GLEx is likewise tied to the temperature class: \u003cstrong\u003e+425 °C in T1\u003c\/strong\u003e, +275 °C in T2, +180 °C in T3, +115 °C in T4, +80 °C in T5 and \u003cstrong\u003e+65 °C in T6\u003c\/strong\u003e. Measuring range and medium temperature contradict each other in the source – feature list -50 … +200 °C, data table -50 … +425 °C: the transmitter measures only up to +200 °C, the 425 °C concern what the tube withstands; the lower value applies, and it should be confirmed before sizing. Both Ex certificate numbers end in X – \u003cstrong\u003eTÜV 21 ATEX 201293 X\u003c\/strong\u003e and \u003cstrong\u003eIECEx TUN 21.0005X\u003c\/strong\u003e – and carry special conditions; the source names heat flowing back, impact and friction as well as electrostatic charging. For none of the four certificates do we hold a document, only the numbers are substantiated; a \u003cstrong\u003eCE mark is not documented\u003c\/strong\u003e. The identifier is used more than once – MK for MKTS, MKTS-GL and MKTS-SP, GN for MKTS-Ex and MKTS-GLEx – which is why the type designation belongs in the order in plain text. Two measuring elements are available only without a transmitter; the insertion length (10 … 300 mm in 5 mm steps) must be stated. Configuration is done with the \u003cstrong\u003eDEV-KMA\u003c\/strong\u003e and the TrComm software.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMarine approval DNV TAA00003GS and EU RO MRA0000052, both versions\u003c\/li\u003e\n\u003cli\u003eMKTS-GLEx additionally Ex ia IIC T6..T1 Ga for zones 0, 1 and 2 with gases\u003c\/li\u003e\n\u003cli\u003eSystem pressure 250 bar, burst pressure 375 bar\u003c\/li\u003e\n\u003cli\u003eStainless steel 1.4571 right into the connector insert, IP 65 \/ IP 68\u003c\/li\u003e\n\u003cli\u003ePt100 or Pt1000 in class A, 24-bit resolution\u003c\/li\u003e\n\u003cli\u003e4 … 20 mA, voltage or resistance directly at the connector\u003c\/li\u003e\n\u003cli\u003eMedium temperature up to +425 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57041754194246,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TEMF_produkt_c693e71c-2fdd-414d-ac46-12cf9d85c283.webp?v=1789734344"},{"product_id":"tima-infrarot-temperatursensor","title":"TIMA infrared temperature sensor","description":"\u003cp\u003eThe \u003cstrong\u003eTIMA\u003c\/strong\u003e is an infrared temperature sensor for non-contact measurement, manufacturer type Müller \u003cstrong\u003eMETS-IR\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt measures on moving, hot or delicate surfaces without touching the medium – where a protective tube would be in the way or cannot be installed at all. Housing, display and the two limit contacts are the same as on the screw-in sensors of the series.\u003c\/p\u003e\n\u003cp\u003eThe sensor evaluates infrared radiation in the spectral range \u003cstrong\u003e8 … 14 µm\u003c\/strong\u003e and covers \u003cstrong\u003e-40 … +1000 °C\u003c\/strong\u003e, with a minimum span of 100 °C. The optical resolution is \u003cstrong\u003e15:1\u003c\/strong\u003e. Accuracy is \u003cstrong\u003e±1.5 °C or ±1.5 %\u003c\/strong\u003e – whichever is greater applies – repeatability ±0.75 °C or ±0.75 %, resolution 0.1 K. Emissivity and transmissivity are adjustable from 0.100 to 1.100 in software. The response time is \u003cstrong\u003e30 ms\u003c\/strong\u003e (t90) at 10 measurements per second.\u003c\/p\u003e\n\u003cp\u003eThe output is \u003cstrong\u003e4 … 20 mA with HART\u003c\/strong\u003e in 3-wire technology, current range 3.8 … 20.5 mA, with a fault signal at 3.6 mA (short circuit) and 21 mA (break). Added to that: a 4-digit 7-segment display in the head, which rotates through \u003cstrong\u003e330°\u003c\/strong\u003e, and \u003cstrong\u003etwo limit contacts\u003c\/strong\u003e, PNP or NPN, 30 VDC \/ 200 mA. Supply is \u003cstrong\u003e24 VDC ±10 %\u003c\/strong\u003e through an eight-pin M12×1 connector – the only connection on this product.\u003c\/p\u003e\n\u003cp\u003eMechanically: process connection from 1\/4\" to 1\" as well as 1\/4NPT to 1\/2NPT, protective tube in 1.4571, Ø 6 × 0.5 mm, 100 mm neck tube optional, PBT GF30 housing, stainless steel measuring head, weight approx. 240 g, protection at least \u003cstrong\u003eIP 65\u003c\/strong\u003e with encapsulated boards. Vibration to IEC 68-2-6, shock to IEC 68-2-27.\u003c\/p\u003e\n\u003cp\u003eThree things belong in the planning. \u003cstrong\u003eThe measuring spot grows with distance\u003c\/strong\u003e – 6.5 mm at the front edge, 16.6 mm at 200 mm, 76.5 mm at one meter; the target must be at least as large as the spot. \u003cstrong\u003eThe ambient temperature is not the medium temperature\u003c\/strong\u003e – the electronics in the head tolerate -20 … +80 °C, the measuring head -20 … +120 °C. And this product measures against the \u003cstrong\u003eopen atmosphere\u003c\/strong\u003e, system pressure 0 bar; it does not belong in a pressurized space, whereas the other sensors of the series withstand PN 25. After 10 minutes of warm-up the reading is dependable.\u003c\/p\u003e\n\u003cp\u003eProgramming requires the \u003cstrong\u003eDEV-KMA\u003c\/strong\u003e configurator with the TrComm software. No CE marking is documented in the manufacturer's data sheet, no declaration of conformity is available, and one must be requested before placing the product on the market in the EU. No explosion protection is documented.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact measurement from -40 to +1000 °C\u003c\/li\u003e\n\u003cli\u003eOptical resolution 15:1, spectral range 8 … 14 µm\u003c\/li\u003e\n\u003cli\u003eAccuracy ±1.5 °C or ±1.5 %, resolution 0.1 K\u003c\/li\u003e\n\u003cli\u003eResponse time 30 ms, 10 measurements per second\u003c\/li\u003e\n\u003cli\u003e4 … 20 mA with HART, 3-wire\u003c\/li\u003e\n\u003cli\u003eDisplay in a head that rotates through 330°\u003c\/li\u003e\n\u003cli\u003eTwo limit contacts, PNP or NPN\u003c\/li\u003e\n\u003cli\u003eEmissivity adjustable in software\u003c\/li\u003e\n\u003cli\u003eProtection at least IP 65\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57245618635078,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TIMA_METS-IR_titelbild_c209e1a8-b964-4983-b7ef-4486cbc6379a.webp?v=1788951931"},{"product_id":"tema-einschraub-temperatursensor-typ-k","title":"TEMA screw-in temperature sensor, type K","description":"\u003cp\u003eThe \u003cstrong\u003eTEMA\u003c\/strong\u003e is a screw-in temperature sensor with a type K thermocouple and integrated measuring amplifier, manufacturer type Müller \u003cstrong\u003eMETS-TS\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is screwed into pipelines and vessels and measures directly in the medium. The process connection ranges from 1\/4\" to 1\" as well as from 1\/4NPT to 1\/2NPT; the protective tube made of \u003cstrong\u003e1.4571\u003c\/strong\u003e stainless steel is Ø 6 × 0.5 mm with insertion lengths from 50 to 1000 mm; a 100 mm neck tube is available as an option. The system pressure is \u003cstrong\u003ePN 25\u003c\/strong\u003e, protection at least \u003cstrong\u003eIP 65\u003c\/strong\u003e with encapsulated boards, any mounting position. The housing is made of PBT GF30, the display top of polycarbonate.\u003c\/p\u003e\n\u003cp\u003eSensor, measuring amplifier, display and two limit contacts sit in one housing: one device at the process connection, one signal to the control system, one value to read on site. A separate transmitter in the control cabinet is no longer needed. Setting is done with the keys at the display or over HART. The \u003cstrong\u003etwo limit contacts\u003c\/strong\u003e are PNP or NPN, 30 VDC \/ 200 mA, optionally 1000 mA.\u003c\/p\u003e\n\u003cp\u003eThe thermocouple is a \u003cstrong\u003etype K (NiCr-Ni)\u003c\/strong\u003e with a tolerance of \u003cstrong\u003e±1.5 °C to DIN EN 60584-2 class 1\u003c\/strong\u003e; the measuring range runs from \u003cstrong\u003e-50 … +200 °C\u003c\/strong\u003e with a minimum span of 50 °C. The amplifier works at \u003cstrong\u003e16 bit\u003c\/strong\u003e with an accuracy of \u003cstrong\u003e0.3 % of the range\u003c\/strong\u003e, 10 measurements per second, 20 ms response time and a filter from 0 to 99 s; the transfer characteristic is linear with temperature. The output is \u003cstrong\u003e4 … 20 mA with a superimposed HART signal\u003c\/strong\u003e in the 2-wire current loop, current range 3.8 … 20.5 mA with 3.6 mA on short circuit and 21 mA on break, supplied from the loop with \u003cstrong\u003e12 … 40 VDC\u003c\/strong\u003e and with reverse polarity protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e The ambient temperature is not the medium temperature – the medium may reach +200 °C, the electronics in the head only -20 … +80 °C; the manufacturer states explicitly for this series that temperatures above +85 °C can destroy the electronics. Which connector carries how many limit contacts is not a free choice: ten connections are available, but two contacts are only possible on M12 five- and eight-pin, on MIL and on the cable. Programming requires the \u003cstrong\u003eDEV-KMA\u003c\/strong\u003e configurator with the TrComm software. No CE marking is documented in the manufacturer's data sheet, and no declaration of conformity is available. The Ex version of this design is the \u003cstrong\u003eTEMD\u003c\/strong\u003e (METS-WTEx).\u003c\/p\u003e\n\u003ch3\u003eBenefits at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eType K thermocouple, ±1.5 °C to DIN EN 60584-2 class 1\u003c\/li\u003e\n\u003cli\u003eMedium -50 to +200 °C, minimum span 50 °C\u003c\/li\u003e\n\u003cli\u003e4 … 20 mA with HART in the 2-wire loop, 0.3 % of the range\u003c\/li\u003e\n\u003cli\u003eDisplay and keys on the device, plus HART\u003c\/li\u003e\n\u003cli\u003eTwo limit contacts, PNP or NPN\u003c\/li\u003e\n\u003cli\u003eProtective tube 1.4571, insertion lengths 50 to 1000 mm\u003c\/li\u003e\n\u003cli\u003eSystem pressure PN 25, protection at least IP 65\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57245618667846,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TEMA_METS-TS_titelbild_749e8a5d-fb95-407c-8fd9-f49a7fb5ec98.webp?v=1788951931"},{"product_id":"trma-raum-temperatursensor-hart","title":"TRMA room temperature sensor, HART","description":"\u003cp\u003eThe \u003cstrong\u003eTRMA\u003c\/strong\u003e is a room temperature sensor, manufacturer type Müller \u003cstrong\u003eMITS\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is built for air-conditioning and cold storage – refrigeration plants on ships, cold rooms, building services. The housing is screwed to the wall through two Ø 4.6 mm holes 45.5 mm apart; the short protective tube of 30 mm and Ø 6 mm reaches into the room. The housing is made of \u003cstrong\u003ePBT GF30\u003c\/strong\u003e in black with flammability rating UL94 HB, measures approx. \u003cstrong\u003e117 × 28 × 32 mm\u003c\/strong\u003e and weighs 50 g; any mounting position.\u003c\/p\u003e\n\u003cp\u003eTwo versions are available: the sensing element sits either \u003cstrong\u003edirectly on the connector\u003c\/strong\u003e – the sensor then outputs its resistance directly – or behind a \u003cstrong\u003eHART transmitter\u003c\/strong\u003e that turns it into 4 … 20 mA. Setting is done in software over HART: LRL, URL, LRV, URV, filter, adjustment and simulation.\u003c\/p\u003e\n\u003cp\u003eThe input takes \u003cstrong\u003eone or two Pt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e in 2-, 3- or 4-wire connection, in classes \u003cstrong\u003eA, B and AA\u003c\/strong\u003e; with an amplifier, one Pt100 is provided for. The measuring range runs \u003cstrong\u003ewithout\u003c\/strong\u003e an amplifier from -30 to \u003cstrong\u003e+90 °C\u003c\/strong\u003e, \u003cstrong\u003ewith\u003c\/strong\u003e an amplifier from -30 to \u003cstrong\u003e+80 °C\u003c\/strong\u003e at a smallest span of 50 K – the same difference applies to the working temperature of the device. The current output delivers \u003cstrong\u003e4 … 20 mA with HART\u003c\/strong\u003e in the 2-wire loop, overall range 3.6 … 21 mA with 21 mA on break, short circuit or underrange. Total error is \u003cstrong\u003e0.3 % of the range\u003c\/strong\u003e at \u003cstrong\u003e16 bit\u003c\/strong\u003e resolution, the measuring rate 10 measurements per second, the filter 0 … 99 s. The sensor is supplied from the HART current loop with \u003cstrong\u003e12 … 40 VDC\u003c\/strong\u003e, with reverse polarity protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e The protective tube is fixed at 30 mm and Ø 6 mm – other lengths are not documented. Protection is at least \u003cstrong\u003eIP 65\u003c\/strong\u003e but depends on the chosen connection; the manufacturer gives no assignment. Ten connections are available, from M12×1 to a cable outlet – two sensors do not work with every connector. Configuration uses the \u003cstrong\u003eHART interface with USB and software\u003c\/strong\u003e; when communicating through a HART modem, a minimum resistance of 250 Ω must be taken into account. UL94 HB is the lowest grade in the series. No CE marking is documented in the manufacturer's data sheet, and no declaration of conformity is available.\u003c\/p\u003e\n\u003ch3\u003eBenefits at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoom sensor for cold rooms, air-conditioning and building services\u003c\/li\u003e\n\u003cli\u003ePt100 or Pt1000, classes A, B and AA\u003c\/li\u003e\n\u003cli\u003eTwo versions: resistance direct or 4 … 20 mA with HART\u003c\/li\u003e\n\u003cli\u003eRange -30 to +90 °C without, -30 to +80 °C with amplifier\u003c\/li\u003e\n\u003cli\u003eTotal error 0.3 % of the range, 16 bit\u003c\/li\u003e\n\u003cli\u003ePBT GF30 housing, only 50 g, wall mounting 45.5 mm\u003c\/li\u003e\n\u003cli\u003eProtective tube 30 mm Ø 6 mm, protection at least IP 65\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57245618700614,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TRMA_MITS_titelbild_7b20f2eb-2ab1-419e-b0c7-e315d0f60e35.webp?v=1788951931"},{"product_id":"tfma-einschraub-temperatursensor-funk","title":"TFMA screw-in temperature sensor, wireless","description":"\u003cp\u003eThe \u003cstrong\u003eTFMA\u003c\/strong\u003e is a screw-in temperature sensor that sends its reading by radio, manufacturer type Müller \u003cstrong\u003eMETS-WR\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is built for measuring points no cable reaches: no signal cable, no supply, no cable route through the plant. The sensor runs from a rechargeable battery and transmits in the license-free \u003cstrong\u003e868 MHz SRD band\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe input is a \u003cstrong\u003ePt100 in 4-wire connection, class A\u003c\/strong\u003e, with a range of \u003cstrong\u003e-50 … +400 °C\u003c\/strong\u003e. The measuring module works with \u003cstrong\u003e16 bit\u003c\/strong\u003e and 0.1 °C resolution at 8 measurements per second; accuracy is \u003cstrong\u003e0.15 % of the range\u003c\/strong\u003e, the temperature coefficient 50 ppm\/K, the filter 0 … 1 s. The radio module transmits at up to 5 dBm (about 3.2 mW) at 19.2 kb\/s.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003erange\u003c\/strong\u003e is \u003cstrong\u003e20 m with the internal\u003c\/strong\u003e and \u003cstrong\u003e100 m with an external antenna\u003c\/strong\u003e – in each case with a clear line of sight; walls, metal and plant components shorten it, and by how much the manufacturer does not say. The external antenna is connected through an SMA plug (option). Two LEDs in red and green under the lens show the state; the device is switched on and off at the top with a \u003cstrong\u003emagnet\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003elithium-ion battery\u003c\/strong\u003e with 3.6 V and 2600 mAh lasts about \u003cstrong\u003esix months at one measurement per minute\u003c\/strong\u003e – and about \u003cstrong\u003e50 days at six measurements per minute\u003c\/strong\u003e. The measuring rate is therefore the most important setting on this device. Without a connector the battery is swapped for charging; with the four-pin M12×1 connector it charges in the device (24 VDC, max. 1 A, about two hours) or the sensor runs permanently from 24 VDC.\u003c\/p\u003e\n\u003cp\u003eMechanically: process connection from 1\/4\" to 1\" as well as 1\/4NPT to 1\/2NPT, protective tube in 1.4571, Ø 6 × 0.5 mm, PBT GF30 housing, PMMA lens with a PA6.6 GF30 screw cap, weight approx. 400 g, system pressure \u003cstrong\u003ePN 25\u003c\/strong\u003e, protection at least \u003cstrong\u003eIP 65\u003c\/strong\u003e with encapsulated boards.\u003c\/p\u003e\n\u003cp\u003eThree points for sizing. \u003cstrong\u003eThe neck tube decides the medium temperature\u003c\/strong\u003e – without one up to 200 °C, with 200 mm up to 400 °C. \u003cstrong\u003eThe battery only charges between 0 and +45 °C\u003c\/strong\u003e, while the device works up to +60 °C; above +45 °C it can therefore measure but not charge. And the ambient temperature is not the medium temperature – the electronics in the head tolerate -20 … +60 °C.\u003c\/p\u003e\n\u003cp\u003eReading out and remote configuration require the \u003cstrong\u003eUSB-RC transceiver\u003c\/strong\u003e (order number 700-00122); it is transmitter and receiver in one and plugs into the PC. The manufacturer names the ETSI directive and the EMC directive 2014\/30\/EU but shows \u003cstrong\u003eno CE marking\u003c\/strong\u003e, and gives \u003cstrong\u003eno radio approval number\u003c\/strong\u003e; no declaration of conformity is available.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadio transmission in the 868 MHz SRD band, no signal cable\u003c\/li\u003e\n\u003cli\u003ePt100 4-wire class A, -50 to +400 °C\u003c\/li\u003e\n\u003cli\u003eAccuracy 0.15 % of the range, 16 bit\u003c\/li\u003e\n\u003cli\u003eRange 20 m internal, 100 m with an external antenna\u003c\/li\u003e\n\u003cli\u003eBattery lasting about 6 months at one measurement per minute\u003c\/li\u003e\n\u003cli\u003eCharging in the device or permanent supply from 24 VDC\u003c\/li\u003e\n\u003cli\u003eSwitched on and off with a magnet\u003c\/li\u003e\n\u003cli\u003eSystem pressure PN 25, protection at least IP 65\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57245618733382,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TFMA_METS-WR_titelbild_229ac3a3-ce21-4990-bacd-638ed12d66fd.webp?v=1788951931"},{"product_id":"tmmb-oberflaechen-temperatursensor-auf-haftmagnet","title":"TMMB surface temperature sensor on magnet","description":"\u003cp\u003eThe \u003cstrong\u003eTMMB\u003c\/strong\u003e is a surface temperature sensor on a holding magnet, manufacturer type Müller \u003cstrong\u003eMETS-WTM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is placed on a pipe or a vessel and holds itself – no drilling, no process connection, no intervention in the medium. The spring-loaded measuring face presses against the surface, the magnet pulls with \u003cstrong\u003e66 N\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis device has no display and no keys\u003c\/strong\u003e – it is set exclusively over HART. Otherwise it is identical to the \u003cstrong\u003eTMMA\u003c\/strong\u003e (METS-WSM), which carries the display. Anyone who wants to read the value on site orders the TMMA.\u003c\/p\u003e\n\u003cp\u003eThe input is a \u003cstrong\u003ePt100 in 4-wire connection\u003c\/strong\u003e in classes A, B and AA (B 1\/3 DIN), with a range of \u003cstrong\u003e-50 … +200 °C\u003c\/strong\u003e at a smallest span of 50 K; up to -50 … +250 °C on request. The output is \u003cstrong\u003e4 … 20 mA with HART\u003c\/strong\u003e in the 2-wire loop, current range 3.8 … 20.5 mA, with 3.6 mA on short circuit and 21 mA on break. Accuracy is \u003cstrong\u003e0.3 % of the range\u003c\/strong\u003e at \u003cstrong\u003e16 bit\u003c\/strong\u003e, the response time 20 ms, the measuring rate 10 measurements per second, the filter 0 … 99 s.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003etwo limit contacts\u003c\/strong\u003e are PNP or NPN with 30 VDC \/ 200 mA, optionally 1000 mA; switching point and hysteresis are adjustable across the whole measuring range, the switching delay from 0.0 to 999.9 s, and failsafe behavior as well. Supply comes from the HART current loop with \u003cstrong\u003e12 … 40 VDC\u003c\/strong\u003e, load R = (UB − 12 V) \/ 21 mA, with reverse polarity protection.\u003c\/p\u003e\n\u003cp\u003eMechanically: holding magnet in \u003cstrong\u003eAlnico 500\u003c\/strong\u003e, measuring face Ø 6 mm spring-loaded with 1.5 mm travel, sensor body stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, PBT GF30 housing, connection either at the side or on top, weight approx. 259 g, system pressure PN 25, protection at least \u003cstrong\u003eIP 65\u003c\/strong\u003e at the electronics.\u003c\/p\u003e\n\u003cp\u003eThree points the manufacturer leaves open and that belong in the planning. \u003cstrong\u003eThe sensor sits with the magnet directly on the hot surface.\u003c\/strong\u003e The measuring face may reach +200 °C, the electronics in the head only +80 °C – how much heat travels into the head is not documented, and above +85 °C the electronics can be destroyed. The \u003cstrong\u003egalvanic isolation applies only between the switching outputs and the amplifier\u003c\/strong\u003e, not against the loop and not against the surface the magnet sits on. And how the \u003cstrong\u003eholding force changes with temperature\u003c\/strong\u003e the source does not say.\u003c\/p\u003e\n\u003cp\u003eTen electrical connections are available – which one carries how many limit contacts is not a free choice: two contacts are only possible on M12 five- and eight-pin, on MIL and on the cable version; on Deutsch DT04 four-pin and on Super Seal, none. Configuration uses the \u003cstrong\u003eHART interface with USB and software\u003c\/strong\u003e, order number 01310-00220; when communicating through a HART modem a resistance of 250 Ω has to be taken into account. No CE marking is documented and no declaration of conformity is available.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring without intervening in the process – holding magnet with 66 N\u003c\/li\u003e\n\u003cli\u003eSpring-loaded measuring face Ø 6 mm, 1.5 mm travel\u003c\/li\u003e\n\u003cli\u003ePt100 4-wire, classes A, B and AA\u003c\/li\u003e\n\u003cli\u003eMedium -50 to +200 °C, up to +250 °C on request\u003c\/li\u003e\n\u003cli\u003e4 … 20 mA with HART, accuracy 0.3 % of the range\u003c\/li\u003e\n\u003cli\u003eTwo limit contacts with adjustable delay\u003c\/li\u003e\n\u003cli\u003eSensor body stainless steel 1.4571, magnet Alnico 500\u003c\/li\u003e\n\u003cli\u003eProtection at least IP 65\u003c\/li\u003e\n\u003cli\u003eVersion with display available as TMMA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57245618766150,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TMMB_METS-WTM_titelbild_762e2e44-6288-4034-aa0b-09e27d501197.webp?v=1788951932"},{"product_id":"tsma-temperatursensor-mit-gefederter-messspitze","title":"TSMA temperature sensor with spring-loaded tip","description":"\u003cp\u003eThe \u003cstrong\u003eTSMA\u003c\/strong\u003e is a temperature sensor with a spring-loaded measuring tip, manufacturer type Müller \u003cstrong\u003eMKTS-SP\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is built for bearing and surface temperatures: the spring presses the tip against the measuring point with \u003cstrong\u003e14 mm of travel\u003c\/strong\u003e and keeps contact even when the component moves or expands with heat – a rigidly screwed-in sensor loses contact at such a point. The process connection is 3\/8\", 1\/2\" or 3\/4\", the insertion length 45 or 65 mm as well as custom, the sensor tube Ø 6 mm made of \u003cstrong\u003e1.4571\u003c\/strong\u003e stainless steel, plus knurled screw 1.4541, compression spring in 1.4310 spring steel, PTFE insulating body, weight approx. 200 g. Protection is \u003cstrong\u003eIP 65 at the electronics and IP 68 at the sensor\u003c\/strong\u003e, encapsulated inside.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis sensor does not withstand process pressure.\u003c\/strong\u003e The process connection has no sealing effect. It measures at the surface and in the bearing, not inside a closed medium; the pressure equipment directive therefore does not apply. Two versions are available: resistance directly on the connector, or \u003cstrong\u003e4 … 20 mA with HART\u003c\/strong\u003e in the 2-wire loop, set in software over HART.\u003c\/p\u003e\n\u003cp\u003eThe input takes \u003cstrong\u003eone or two Pt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e in 2-, 3- or 4-wire connection in classes A, B and AA, alternatively a \u003cstrong\u003etype K thermocouple with a cross-band\u003c\/strong\u003e. The range runs from \u003cstrong\u003e-50 … +150 °C\u003c\/strong\u003e at a smallest span of 50 K. Total accuracy is \u003cstrong\u003e0.3 % of the range\u003c\/strong\u003e at \u003cstrong\u003e16 bit\u003c\/strong\u003e, the response time 20 ms, the measuring rate 10 measurements per second, the transfer characteristic linear with temperature. The sensor is supplied from the HART current loop with \u003cstrong\u003e12 … 40 VDC\u003c\/strong\u003e, with reverse polarity protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e The ambient temperature is not the medium temperature – without a transmitter the ambient may be -20 … +100 °C, with a transmitter only -20 … +80 °C; which neck length or insulation a hot medium requires, the source does not say. The MK product code is used three times by the manufacturer – MKTS, MKTS-GL and MKTS-SP, with a different meaning of the following digits in each case; when ordering, the type designation belongs in plain text, not just the code. Ten electrical connections are available; two sensors do not work with every connector. Configuration uses the \u003cstrong\u003eHART interface with USB and software\u003c\/strong\u003e, order number 01310-00220. No CE marking is documented in the manufacturer's data sheet, and no declaration of conformity is available for this version. The version with IO-Link is the \u003cstrong\u003eTSMB\u003c\/strong\u003e (MKTS-SPIO).\u003c\/p\u003e\n\u003ch3\u003eBenefits at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpring-loaded measuring tip, 14 mm ±1 mm of travel\u003c\/li\u003e\n\u003cli\u003eKeeps contact on moving and expanding components\u003c\/li\u003e\n\u003cli\u003ePt100, Pt1000 or type K thermocouple\u003c\/li\u003e\n\u003cli\u003eRange -50 to +150 °C, smallest span 50 K\u003c\/li\u003e\n\u003cli\u003eResistance direct or 4 … 20 mA with HART, 0.3 % of the range\u003c\/li\u003e\n\u003cli\u003eInsertion length 45 or 65 mm, sensor tube 1.4571\u003c\/li\u003e\n\u003cli\u003eIP 65 at the electronics, IP 68 at the sensor\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57245618831686,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TSMA_MKTS-SP_titelbild_2a57f779-2669-4376-8a67-3184cf076f1f.webp?v=1788951932"},{"product_id":"tcma-thermoelement-kabelfuehler","title":"TCMA thermocouple cable probe","description":"\u003cp\u003eThe \u003cstrong\u003eTCMA\u003c\/strong\u003e is a thermocouple cable sensor, manufacturer type Müller \u003cstrong\u003eTE-K1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt measures at measuring points where there is no space for a connection head: a rigid protective tube, pressed firmly at the transition, and a fixed cable leading directly to the evaluation. There is no terminal compartment, no electronics and no housing – the sensor is inserted into a bore, a compression fitting or a flange. The protective tube is made of \u003cstrong\u003e1.4571\u003c\/strong\u003e (316Ti) and is approved for up to \u003cstrong\u003e600 °C\u003c\/strong\u003e, with \u003cstrong\u003eØ 4, 5 or 6 mm\u003c\/strong\u003e and a wall thickness of \u003cstrong\u003e0.25 … 1 mm\u003c\/strong\u003e; the nominal length is between \u003cstrong\u003e30 and 70 mm\u003c\/strong\u003e, up to \u003cstrong\u003e2000 mm\u003c\/strong\u003e on request. The protection class is \u003cstrong\u003eIP 65 up to 250 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe transition to the cable is made with a hexagonal crimp, with a ring crimp available on request; a shrink sleeve serves as bend protection, optionally a spring. Five cable constructions from PVC to glass silk are available, standard \u003cstrong\u003e2 m\u003c\/strong\u003e long. The response time for 6×0.5 mm is \u003cstrong\u003et90 30.9 s\u003c\/strong\u003e, and for 6×1 mm is \u003cstrong\u003et90 22.1 s\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe measuring element is a thermocouple \u003cstrong\u003eType J (Fe-CuNi)\u003c\/strong\u003e or \u003cstrong\u003eType K (NiCr-Ni)\u003c\/strong\u003e, single or double, without insulating material. The application range for Type J is from \u003cstrong\u003e-200 … +700 °C\u003c\/strong\u003e and for Type K from \u003cstrong\u003e-200 … +1000 °C\u003c\/strong\u003e. The limit deviation follows \u003cstrong\u003eDIN EN 60584-2 Class 1\u003c\/strong\u003e: \u003cstrong\u003e±1.5 °C\u003c\/strong\u003e in the range -40 … 375 °C and \u003cstrong\u003e±0.004|t|\u003c\/strong\u003e above. The \u003cstrong\u003ethermoelectric voltage is immediately available\u003c\/strong\u003e at the output, at open ends of 70 mm or at a TE plug; a transmitter is not documented. For insulation, the manufacturer only specifies the test voltage \u003cstrong\u003e500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The application range is determined by the cable, not by the sensor – PVC withstands \u003cstrong\u003e-5 … +70 °C\u003c\/strong\u003e, silicone -45 … +180 °C, PTFE -75 … +250 °C and glass silk \u003cstrong\u003e-60 … +550 °C\u003c\/strong\u003e; a Type K up to +1000 °C is useless with a PVC cable. The ambient temperature is not the medium temperature, and for a cable sensor, the cable is in the ambient. IP 65 does not apply to the version with shield braiding. The accuracy table extends further than the application range: Type J is specified up to 750 °C there, but in the application range up to 700 °C. A terminal assignment is not documented – the polarity must be measured before connecting. Weight, system pressure, CE mark and explosion protection are not documented. Both versions bear the product identification \u003cstrong\u003eKT\u003c\/strong\u003e; they are distinguished solely by the thermocouple type: \u003cstrong\u003e0 … 3\u003c\/strong\u003e is the TE-K1, 4 … 7 is the TE-K1G. The version with GL type approval is the \u003cstrong\u003eTCMB\u003c\/strong\u003e (TE-K1G).\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eThermocouple Type J or Type K, application range up to +1000 °C\u003c\/li\u003e\n\n\u003cli\u003eLimit deviation according to DIN EN 60584-2 Class 1\u003c\/li\u003e\n\n\u003cli\u003eProtective tube 1.4571 (316Ti), Ø 4, 5 or 6 mm, up to 600 °C\u003c\/li\u003e\n\n\u003cli\u003eNominal length 30 … 70 mm, up to 2000 mm on request\u003c\/li\u003e\n\n\u003cli\u003eFive cable constructions from PVC to glass silk, -5 … +550 °C\u003c\/li\u003e\n\n\u003cli\u003eGL version available as TCMB (TE-K1G)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356926746950,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TCMA_produkt_4b27e6f5-e566-4848-b323-4714ca20567a.webp?v=1789243659"},{"product_id":"tkma-thermoelement-mit-anschlusskopf-b","title":"TKMA thermocouple with type B connection head","description":"\u003cp\u003eThe \u003cstrong\u003eTKMA\u003c\/strong\u003e is a thermocouple with connection head B, manufacturer type Müller \u003cstrong\u003eTE-MR1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is designed for permanent installation in pipes, tanks, and systems where the measuring point requires a wired connection. The aluminum \u003cstrong\u003econnection head\u003c\/strong\u003e is located above the process, accommodates a ceramic terminal block with connection posts, and routes the cable through an \u003cstrong\u003eM20x1.5\u003c\/strong\u003e gland; the process connection \u003cstrong\u003eM24x1.5\u003c\/strong\u003e is located on the head, and the protection class is \u003cstrong\u003eIP 54\u003c\/strong\u003e. The protection tube made of \u003cstrong\u003e1.4571 (316Ti)\u003c\/strong\u003e or \u003cstrong\u003e2.4816 (Inconel 600)\u003c\/strong\u003e withstands temperatures up to 600 °C or 1100 °C, respectively. Nominal lengths range from 50 to 1000 mm, with a maximum length of \u003cstrong\u003e2000 mm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eTwo designs cover both mounting types: the screw-in sensor (ES) with process thread on the pipe and the immersion sensor (ET), which is mounted with accessories; available with twelve protection tube diameters from \u003cstrong\u003e1.5 to 15 mm\u003c\/strong\u003e. In the case of the mineral-insulated cable element, the first approximately \u003cstrong\u003e50 mm\u003c\/strong\u003e from the head are rigid, the rest flexible – allowing the sensor to be guided to the measuring point even without straight access. The manufacturer lists connection cables, compression fittings, and a \u003cstrong\u003etransmitter\u003c\/strong\u003e as accessories.\u003c\/p\u003e\n\u003cp\u003eThe measuring element is a thermocouple \u003cstrong\u003eType J (Fe-CuNi)\u003c\/strong\u003e or \u003cstrong\u003eType K (NiCr-Ni)\u003c\/strong\u003e, single or double, as a standard element or as a mineral-insulated cable element. The operating range for Type J is from \u003cstrong\u003e-200 ... +700 °C\u003c\/strong\u003e, for Type K from \u003cstrong\u003e-200 ... +1000 °C\u003c\/strong\u003e; the limit deviation follows \u003cstrong\u003eDIN EN 60584-2 Class 1\u003c\/strong\u003e with \u003cstrong\u003e±1.5 °C\u003c\/strong\u003e from -40 ... 375 °C and above ±0.004|t|. The thermoelectric voltage is available at the ceramic terminal block in the head, and the test voltage is \u003cstrong\u003e500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore ordering, please note:\u003c\/strong\u003e The ambient temperature is not the medium temperature – the connection head is limited to \u003cstrong\u003e480 °C\u003c\/strong\u003e, while the measuring element reaches up to 1000 °C; here, the head, not the element, is decisive. The accuracy table for Type J extends to 750 °C, but the operating range up to 700 °C is authoritative. \u003cstrong\u003eIP 54 applies only to the connection head\u003c\/strong\u003e; the source does not specify a protection class for the protection tube. For the transmitter, it does not specify the type, output signal, or power supply, and terminal assignment is also missing. Weight, system pressure, CE mark, and explosion protection are not documented, and \u003cstrong\u003eDIN EN 60584-2 Class 1\u003c\/strong\u003e is not a product approval; this version does not have type approval. The GL version is the \u003cstrong\u003eTKMB\u003c\/strong\u003e (TE-MR1G, TAA00002H3); both carry the product identifier \u003cstrong\u003eKC\u003c\/strong\u003e, distinguished only by the first digit – 0 ... 3 for TKMA, 4 ... 7 for TKMB.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eThermocouple Type J or Type K, single or double\u003c\/li\u003e\n\n\u003cli\u003eOperating range Type J -200 ... +700 °C, Type K -200 ... +1000 °C\u003c\/li\u003e\n\n\u003cli\u003eConnection head B made of aluminum, IP 54, cable entry M20x1.5\u003c\/li\u003e\n\n\u003cli\u003eProtection tube 1.4571 or 2.4816, Ø 1.5 to 15 mm\u003c\/li\u003e\n\n\u003cli\u003eInstallation lengths 50 to 1000 mm, maximum length 2000 mm\u003c\/li\u003e\n\n\u003cli\u003eGL version TAA00002H3 available as TKMB\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356926812486,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TKMA_produkt_9d9cb0ff-142f-4e0c-bdbc-a8d86fe9c15e.webp?v=1789243685"},{"product_id":"tcmb-thermoelement-kabelfuehler-gl","title":"TCMB thermocouple cable probe, GL","description":"\u003cp\u003eThe \u003cstrong\u003eTCMB\u003c\/strong\u003e is a thermocouple cable sensor with GL type approval, manufacturer type Müller \u003cstrong\u003eTE-K1G\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is the approved version of the cable sensor for measuring points where there is no space for a connection head: rigid protective tube, pressed transition, fixed cable for evaluation, no terminal compartment and no electronics. Compared to the \u003cstrong\u003eTE-K1\u003c\/strong\u003e, it is shorter – the nominal length is between \u003cstrong\u003e30 and 70 mm\u003c\/strong\u003e and is limited to \u003cstrong\u003e200 mm\u003c\/strong\u003e, the cable to \u003cstrong\u003e6 m\u003c\/strong\u003e. The protective tube is made of \u003cstrong\u003e1.4571\u003c\/strong\u003e (316Ti) and is approved up to \u003cstrong\u003e600 °C\u003c\/strong\u003e, with \u003cstrong\u003eØ 4, 5 or 6 mm\u003c\/strong\u003e and a wall thickness of \u003cstrong\u003e0.25 … 1 mm\u003c\/strong\u003e; the protection class is \u003cstrong\u003eIP 65 up to 250 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe transition to the cable is pressed, with a heat shrink tube serving as kink protection, optionally a spring. Five cable designs from PVC to glass silk are available, standard length \u003cstrong\u003e2 m\u003c\/strong\u003e. The response time is \u003cstrong\u003et90 30.9 s\u003c\/strong\u003e for 6x0.5 mm, and \u003cstrong\u003et90 22.1 s\u003c\/strong\u003e for 6x1 mm.\u003c\/p\u003e\n\u003cp\u003eThe measuring element is a thermocouple \u003cstrong\u003eType J (Fe-CuNi)\u003c\/strong\u003e or \u003cstrong\u003eType K (NiCr-Ni)\u003c\/strong\u003e, single or double, without insulating material. The operating range for Type J is \u003cstrong\u003e-200 … +700 °C\u003c\/strong\u003e and for Type K it is \u003cstrong\u003e-200 … +1000 °C\u003c\/strong\u003e. The limit deviation follows \u003cstrong\u003eDIN EN 60584-2 Class 1\u003c\/strong\u003e: \u003cstrong\u003e±1.5 °C\u003c\/strong\u003e in the range -40 … 375 °C and \u003cstrong\u003e±0.004|t|\u003c\/strong\u003e above. The \u003cstrong\u003ethermoelectric voltage is directly available\u003c\/strong\u003e at the output, at open ends or at a TE plug; a transmitter is not documented. For insulation, the manufacturer only specifies a test voltage of \u003cstrong\u003e500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e The approval \u003cstrong\u003eGL TAA00002H3\u003c\/strong\u003e is confirmed as a mark and number, not as a certificate; the certificate must be requested before making an assurance to the classification society. Both versions bear the product identification \u003cstrong\u003eKT\u003c\/strong\u003e; they are distinguished only by the thermocouple type: \u003cstrong\u003e4 … 7\u003c\/strong\u003e is the TE-K1G, 0 … 3 is the TE-K1. The nominal lengths are stated twice differently in the data sheet – the characteristic values block lists 30, 46, 50 and 70 mm, the order key additionally 50 mm for Ø 4; the desired length must be specified in plain text in the order. The operating range is determined by the cable, not by the sensor: PVC withstands -5 … +70 °C, silicone -45 … +180 °C, PTFE -75 … +250 °C, glass silk -60 … +550 °C. The ambient temperature is not the medium temperature, and for cable sensors, the cable is in the ambient environment. IP 65 does not apply to the version with screen braiding. CE mark and explosion protection are not documented. The version without GL approval is the \u003cstrong\u003eTCMA\u003c\/strong\u003e (TE-K1), available up to 2000 mm.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eGL type approval TAA00002H3 documented in manufacturer's data sheet\u003c\/li\u003e\n\n\u003cli\u003eThermocouple type J or type K, operating range up to +1000 °C\u003c\/li\u003e\n\n\u003cli\u003eLimit deviation according to DIN EN 60584-2 Class 1\u003c\/li\u003e\n\n\u003cli\u003eProtective tube 1.4571 (316Ti), Ø 4, 5 or 6 mm, up to 600 °C\u003c\/li\u003e\n\n\u003cli\u003eNominal length 30 … 70 mm, maximum 200 mm\u003c\/li\u003e\n\n\u003cli\u003eCable standard 2 m, maximum 6 m, PVC to glass silk\u003c\/li\u003e\n\n\u003cli\u003eVersion without GL up to 2000 mm as TCMA (TE-K1)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356926878022,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TCMB_produkt_9d1febc8-db77-463b-8872-ce7f08ddd42b.webp?v=1789243684"},{"product_id":"tkmb-thermoelement-mit-anschlusskopf-b-gl","title":"TKMB thermocouple with type B connection head, GL","description":"\u003cp\u003eThe \u003cstrong\u003eTKMB\u003c\/strong\u003e is a thermocouple with connection head B in the GL type-approved version, manufacturer type Müller \u003cstrong\u003eTE-MR1G\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is designed for fixed plant installation at measuring points where type approval is required: The manufacturer's sheet lists the GL mark with the number \u003cstrong\u003eTAA00002H3\u003c\/strong\u003e. The aluminum \u003cstrong\u003econnection head\u003c\/strong\u003e accommodates a ceramic base with connection posts. The process connection \u003cstrong\u003eM24x1.5\u003c\/strong\u003e and the cable gland \u003cstrong\u003eM20x1.5\u003c\/strong\u003e are located on the head, and the protection class is \u003cstrong\u003eIP 54\u003c\/strong\u003e. The protection tube made of \u003cstrong\u003e1.4571 (316Ti)\u003c\/strong\u003e or \u003cstrong\u003e2.4816 (Inconel 600)\u003c\/strong\u003e withstands temperatures up to 600 °C or 1100 °C respectively, and the process pressure is \u003cstrong\u003emax. PN16\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eCompared to the TKMA, this is not the same product with an additional marking: This version is limited to a length of \u003cstrong\u003e200 mm\u003c\/strong\u003e instead of 2000 mm and has a different accessory set. The source does not list a transmitter here as an accessory, but it does include connection cables up to 6 m, compression fittings, and a sheet metal flange. Screw-in (ES) and immersion (ET) designs are available, as well as protection tube diameters of \u003cstrong\u003e3 to 15 mm\u003c\/strong\u003e; the selection is limited for mineral insulated elements and in the immersion design.\u003c\/p\u003e\n\u003cp\u003eThe measuring element is a \u003cstrong\u003eType J (Fe-CuNi)\u003c\/strong\u003e or \u003cstrong\u003eType K (NiCr-Ni)\u003c\/strong\u003e thermocouple, single or double, as a standard element or as a mineral insulated element. The operating range for Type J is from \u003cstrong\u003e-200 ... +700 °C\u003c\/strong\u003e, and for Type K from \u003cstrong\u003e-200 ... +1000 °C\u003c\/strong\u003e; the limit deviation follows \u003cstrong\u003eDIN EN 60584-2 Class 1\u003c\/strong\u003e with \u003cstrong\u003e±1.5 °C\u003c\/strong\u003e from -40 ... 375 °C and ±0.004|t| above. The thermovoltage is available at the ceramic base in the head, the test voltage is \u003cstrong\u003e500 VDC\u003c\/strong\u003e, and the response time on the 3x0.4 mm tube is \u003cstrong\u003et90 6 s\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The approval is documented as a mark and number, not as a certificate – the manufacturer's sheet does not mention a certifying body, and the certificate is not available; it should be requested before any assurance. Both bear the product identification \u003cstrong\u003eKC\u003c\/strong\u003e, distinguished solely by the first digit of the order code: \u003cstrong\u003e4 ... 7\u003c\/strong\u003e for the TKMB, 0 ... 3 for the TKMA – the English version prints 0 ... 3 for the GL variant here, which would make it unorderable unnoticed. The ambient temperature is not the medium temperature: The head is limited to \u003cstrong\u003e480 °C\u003c\/strong\u003e, the measuring element reaches up to 1000 °C. The source states 15 s for the 6x0.5 mm tube here, while the TKMA sheet states 30.9 s – it does not explain the difference. IP 54 applies only to the connection head; terminal assignment, CE mark, and explosion protection are not documented.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eGL type approval TAA00002H3, documented as a mark and number\u003c\/li\u003e\n\n\u003cli\u003eThermocouple Type J or Type K, single or double\u003c\/li\u003e\n\n\u003cli\u003eOperating range Type J -200 ... +700 °C, Type K -200 ... +1000 °C\u003c\/li\u003e\n\n\u003cli\u003eProcess pressure max. PN16, installation lengths 50 to 200 mm\u003c\/li\u003e\n\n\u003cli\u003eAluminum connection head B, IP 54, cable gland M20x1.5\u003c\/li\u003e\n\n\u003cli\u003eProtection tube 1.4571 or 2.4816, Ø 3 to 15 mm\u003c\/li\u003e\n\n\u003cli\u003eVersion without GL up to 2000 mm length available as TKMA\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356926976326,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TKMB_produkt_98442ae0-e2b7-450d-9939-b975dd78c200.webp?v=1789243685"},{"product_id":"tcmc-widerstandsthermometer-kabelfuehler","title":"TCMC resistance thermometer cable probe","description":"\u003cp\u003eThe \u003cstrong\u003eTCMC\u003c\/strong\u003e is a resistance thermometer cable probe, manufacturer type Müller \u003cstrong\u003eWT-K1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt measures at measuring points where there is no space for a connection head: a rigid protective tube, pressed firmly at the transition, and a fixed cable directly leading to evaluation. There is no terminal compartment and no electronics – the probe is inserted into a bore, a compression fitting, or a flange. The protective tube is made of \u003cstrong\u003e1.4571\u003c\/strong\u003e (316Ti) and is approved up to \u003cstrong\u003e600 °C\u003c\/strong\u003e, with \u003cstrong\u003eØ 4, 5, or 6 mm\u003c\/strong\u003e and a wall thickness of \u003cstrong\u003e0.25 … 1 mm\u003c\/strong\u003e; the nominal lengths are \u003cstrong\u003e30, 46, 50, and 70 mm\u003c\/strong\u003e, the maximum length \u003cstrong\u003e2000 mm\u003c\/strong\u003e. The protection class is \u003cstrong\u003eIP 65 up to 250 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe transition to the cable is pressed; a heat shrink tube serves as bend protection, optionally a spring or a crimped transition. The standard cable length is \u003cstrong\u003e2 m\u003c\/strong\u003e. The response time at 6×0.5 mm is \u003cstrong\u003et90 30.9 s\u003c\/strong\u003e, at 6×1 mm \u003cstrong\u003et90 22.1 s\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eA \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, single or double, in \u003cstrong\u003e2-, 3- or 4-wire circuit\u003c\/strong\u003e and without insulating material, serves as the measuring element. The sensor's operating range extends from \u003cstrong\u003e-200 … +450 °C\u003c\/strong\u003e; the accuracy can be ordered in five stages from \u003cstrong\u003eClass A\u003c\/strong\u003e to \u003cstrong\u003eB1\/10DIN\u003c\/strong\u003e. The \u003cstrong\u003eresistance value is immediately available\u003c\/strong\u003e at the output, at open ends of 70 mm; the core colors are shown in the data sheet \u003cstrong\u003eaccording to DIN 60751\u003c\/strong\u003e. A transmitter is not documented. For insulation, the manufacturer only specifies a test voltage of \u003cstrong\u003e500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e The operating range is determined by the cable, not the probe – PVC withstands \u003cstrong\u003e-5 … +70 °C\u003c\/strong\u003e, silicone -45 … +180 °C, PTFE -75 … +205 °C, and glass fiber \u003cstrong\u003e-60 … +550 °C\u003c\/strong\u003e; a sensor up to +450 °C is useless with a PVC cable. The ambient temperature is not the medium temperature – with a cable probe, the cable is in the ambient environment. IP 65 does not apply to the version with braided shielding. The source does not specify a standard for the accuracy classes – if a limit deviation in Kelvin needs to be guaranteed, it must be requested in writing from the manufacturer. In the order key, the digit 3 is missing for the nominal length; digits 0, 1, 2, 4, and 5 are specified; therefore, the length must be clearly stated in the order. Weight, system pressure, CE mark, and explosion protection are not documented. Both versions carry the product identifier \u003cstrong\u003eKW\u003c\/strong\u003e; they are distinguished only by the sensor element position: \u003cstrong\u003e0 … 3\u003c\/strong\u003e is the WT-K1, 4 … 7 is the WT-K1G. The GL version is the \u003cstrong\u003eTCMD\u003c\/strong\u003e (WT-K1G) with the number \u003cstrong\u003eGL TAA00002H5\u003c\/strong\u003e, only with Ø 6 mm and two nominal lengths.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003ePt100 or Pt1000, single or double, -200 … +450 °C\u003c\/li\u003e\n\n\u003cli\u003e2-, 3- or 4-wire circuit, core colors according to DIN 60751\u003c\/li\u003e\n\n\u003cli\u003eProtective tube 1.4571 (316Ti), Ø 4, 5 or 6 mm, up to 600 °C\u003c\/li\u003e\n\n\u003cli\u003eNominal length 30 … 70 mm, up to 2000 mm on request\u003c\/li\u003e\n\n\u003cli\u003eFive cable constructions from PVC to glass fiber, -5 … +550 °C\u003c\/li\u003e\n\n\u003cli\u003eGL version available as TCMD (WT-K1G)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356927009094,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TCMC_produkt_7fc0bea8-e120-475c-84c7-d19caf0513be.webp?v=1789243684"},{"product_id":"tkmc-widerstandsthermometer-mit-anschlusskopf-b","title":"TKMC resistance thermometer with type B connection head","description":"\u003cp\u003eThe \u003cstrong\u003eTKMC\u003c\/strong\u003e is a resistance thermometer with connection head B, manufacturer type Müller \u003cstrong\u003eWT-MR1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is designed for fixed system installation in pipes, tanks, and systems where the measuring point requires a wireable connection. The aluminum \u003cstrong\u003econnection head\u003c\/strong\u003e sits above the process, accommodates a ceramic base with connection posts, and routes the cable out through an \u003cstrong\u003eM20x1.5\u003c\/strong\u003e screw connection; the process connection at the head is \u003cstrong\u003eM24x1.5\u003c\/strong\u003e, and the protection class is \u003cstrong\u003eIP 54\u003c\/strong\u003e. The protective tube made of \u003cstrong\u003e1.4571 (316Ti)\u003c\/strong\u003e or \u003cstrong\u003e2.4816 (Inconel 600)\u003c\/strong\u003e withstands temperatures \u003cstrong\u003eup to 600 °C\u003c\/strong\u003e, with nominal lengths ranging from 50 to 1000 mm and a maximum length of \u003cstrong\u003e2000 mm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eTwo designs cover both mounting types: the screw-in sensor (ES) with process thread on the pipe, and the immersion sensor (ET), which is mounted with accessories; in addition, eleven protection tube diameters from \u003cstrong\u003e3 to 15 mm\u003c\/strong\u003e are available. For the mineral-insulated element, the first approximately \u003cstrong\u003e50 mm\u003c\/strong\u003e from the head are rigid, and the rest is flexible – allowing the sensor to be inserted even without direct access. The manufacturer lists connection cables, compression fittings, and a \u003cstrong\u003etransmitter\u003c\/strong\u003e as accessories.\u003c\/p\u003e\n\u003cp\u003eThe measuring element is a \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, single or double, in \u003cstrong\u003e2-, 3- or 4-wire configuration\u003c\/strong\u003e, as a standard element or as a mineral-insulated element. The sensor's operating range is \u003cstrong\u003e-200 ... +450 °C\u003c\/strong\u003e, with accuracy ranging in five steps from \u003cstrong\u003eClass A to B1\/10DIN\u003c\/strong\u003e. The resistance is located on the ceramic base in the head, and the test voltage is \u003cstrong\u003e500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The ambient temperature is not the medium temperature – the head is limited to \u003cstrong\u003e480 °C\u003c\/strong\u003e, and the element ends at \u003cstrong\u003e450 °C\u003c\/strong\u003e. The source does not specify a standard for the accuracy classes; those who need figures for the limit deviation should request them from the manufacturer. \u003cstrong\u003eIP 54 applies only to the connection head\u003c\/strong\u003e; the source does not specify a protection class for the protective tube. For the mineral-insulated element, the English version additionally mentions 1.5 mm, but the order key does not offer a digit for this – here, \u003cstrong\u003e3, 4.5, and 6 mm\u003c\/strong\u003e apply. The source does not specify the type, output signal, or supply for the transmitter, and a terminal assignment is missing. Weight, system pressure, CE mark, and explosion protection are not documented, and it does not have type approval. The GL version is the \u003cstrong\u003eTKMD\u003c\/strong\u003e (WT-MR1G, TAA00002H5); both carry the product identifier \u003cstrong\u003eKD\u003c\/strong\u003e, differing only in the first digit – 0 ... 3 for TKMC, 4 ... 7 for TKMD.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a Glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003ePt100 or Pt1000, single or double, 2-, 3- or 4-wire configuration\u003c\/li\u003e\n\n\u003cli\u003eOperating range -200 ... +450 °C, five classes from Class A to B1\/10DIN\u003c\/li\u003e\n\n\u003cli\u003eConnection head B made of aluminum, IP 54, cable gland M20x1.5\u003c\/li\u003e\n\n\u003cli\u003eProtective tube 1.4571 or 2.4816, Ø 3 to 15 mm, up to 600 °C\u003c\/li\u003e\n\n\u003cli\u003eInsertion lengths 50 to 1000 mm, maximum 2000 mm\u003c\/li\u003e\n\n\u003cli\u003eGL version TAA00002H5 available as TKMD\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356927107398,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TKMC_produkt_7675337e-980b-4223-a5fe-1801b825aa0d.webp?v=1789243716"},{"product_id":"tcmd-widerstandsthermometer-kabelfuehler-gl","title":"TCMD resistance thermometer cable probe, GL","description":"\u003cp\u003eThe \u003cstrong\u003eTCMD\u003c\/strong\u003e is a resistance thermometer cable sensor with GL type approval, manufacturer type Müller \u003cstrong\u003eWT-K1G\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is the approved version of the cable sensor for measuring points where there is no space for a connection head: rigid protective tube, press-fitted transition, fixed cable for evaluation, no terminal compartment, and no electronics. Compared to the \u003cstrong\u003eWT-K1\u003c\/strong\u003e, the selection is limited – it is \u003cstrong\u003eonly available with Ø 6 mm\u003c\/strong\u003e and in nominal lengths of \u003cstrong\u003e46 or 70 mm\u003c\/strong\u003e, limited to \u003cstrong\u003e200 mm\u003c\/strong\u003e, and the cable to \u003cstrong\u003e6 m\u003c\/strong\u003e. The protective tube is made of \u003cstrong\u003e1.4571\u003c\/strong\u003e (316Ti) and is approved for up to \u003cstrong\u003e600 °C\u003c\/strong\u003e; the protection class is \u003cstrong\u003eIP 65 up to 250 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe transition to the cable is pressed, and a heat shrink tube, optionally a spring, serves as bend protection. Five cable constructions from PVC to glass silk are available, standard length \u003cstrong\u003e2 m\u003c\/strong\u003e. The response time is \u003cstrong\u003et90 30.9 s\u003c\/strong\u003e for 6x0.5 mm and \u003cstrong\u003et90 22.1 s\u003c\/strong\u003e for 6x1 mm.\u003c\/p\u003e\n\u003cp\u003eA \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, single or double, is used as the measuring element, in a \u003cstrong\u003e2-, 3- or 4-wire circuit\u003c\/strong\u003e and without insulation material. The sensor's operating range extends from \u003cstrong\u003e-200 ... +450 °C\u003c\/strong\u003e, and the accuracy can be ordered in five grades from \u003cstrong\u003eClass A\u003c\/strong\u003e to \u003cstrong\u003eB1\/10DIN\u003c\/strong\u003e. The \u003cstrong\u003eresistance value is available immediately\u003c\/strong\u003e at the output, with ferrule on open ends of 70 mm; a transmitter is not documented. The insulation is tested with \u003cstrong\u003e500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The approval \u003cstrong\u003eGL TAA00002H5\u003c\/strong\u003e is documented as a mark and number, not as a certificate; the certificate must be requested before making an assurance to the classification society. Both versions bear the product identification \u003cstrong\u003eKW\u003c\/strong\u003e; they are differentiated solely by the sensor element position: \u003cstrong\u003e4 ... 7\u003c\/strong\u003e is the WT-K1G, 0 ... 3 is the WT-K1. Terminal assignment is not documented for this version – unlike the TCMC, which shows the colors according to DIN 60751; the assignment should be measured before connecting. The operating range is determined by the cable, not the sensor: PVC withstands -5 ... +70 °C, silicone -45 ... +180 °C, PTFE -75 ... +205 °C, glass silk -60 ... +550 °C. The ambient temperature is not the medium temperature, and for cable sensors, the cable is in the ambient environment. IP 65 does not apply to the shielded braid version. The source does not specify a standard for the accuracy classes; wall thickness, weight, system pressure, CE mark, and explosion protection are not documented. The version without GL approval is the \u003cstrong\u003eTCMC\u003c\/strong\u003e (WT-K1), with three diameters and up to 2000 mm.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eGL type approval TAA00002H5 documented in manufacturer sheet\u003c\/li\u003e\n\n\u003cli\u003ePt100 or Pt1000, single or double, -200 ... +450 °C\u003c\/li\u003e\n\n\u003cli\u003e2-, 3- or 4-wire circuit, Class A to B1\/10DIN\u003c\/li\u003e\n\n\u003cli\u003eProtective tube 1.4571 (316Ti), Ø 6 mm, up to 600 °C\u003c\/li\u003e\n\n\u003cli\u003eNominal length 46 or 70 mm, maximum 200 mm\u003c\/li\u003e\n\n\u003cli\u003eStandard cable 2 m, maximum 6 m, PVC to glass silk\u003c\/li\u003e\n\n\u003cli\u003eVersion with three diameters as TCMC (WT-K1)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356927369542,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TCMD_produkt_94362d05-6d77-4d03-8405-fc81b00c5894.webp?v=1789243684"},{"product_id":"tbma-mantel-thermoelement","title":"TBMA mineral insulated thermocouple","description":"\u003cp\u003eThe \u003cstrong\u003eTBMA\u003c\/strong\u003e is a sheathed thermocouple with a flexible protection tube and a fixed connection cable, manufacturer type Müller \u003cstrong\u003eTE-MK1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt measures in installation locations that a rigid protection tube cannot reach. The sheathed tube can be bent to a radius of \u003cstrong\u003emin. 5 × Ø protection tube\u003c\/strong\u003e; the cable is firmly attached to the sensor, eliminating the need for a connection head that requires space and wall clearance. The protection tube is made of \u003cstrong\u003e2.4816\u003c\/strong\u003e (Inconel 600), specified as a material up to \u003cstrong\u003e1100 °C\u003c\/strong\u003e, the connecting sleeve is made of \u003cstrong\u003e1.4571\u003c\/strong\u003e (316Ti), the protection class is \u003cstrong\u003eIP 65\u003c\/strong\u003e up to \u003cstrong\u003e250 °C\u003c\/strong\u003e. Available in four diameters from \u003cstrong\u003e1.5 to 6 mm\u003c\/strong\u003e and with a nominal length of \u003cstrong\u003e100 mm\u003c\/strong\u003e as standard, up to \u003cstrong\u003e2000 mm\u003c\/strong\u003e on request, it also fits into narrow and deep bores. Clamp fittings and sheet metal flanges from the accessories are used for fastening.\u003c\/p\u003e\n\u003cp\u003eFor \u003cstrong\u003eØ 3 mm\u003c\/strong\u003e, the manufacturer specifies a response time of \u003cstrong\u003et90 5 s\u003c\/strong\u003e and \u003cstrong\u003et50 2 s\u003c\/strong\u003e – meaning the sensor still responds usefully to rapid temperature changes. Connection is via open ends or via TE connectors in standard or mini design; five cable versions from PVC to glass silk are available, with a standard length of 2 m.\u003c\/p\u003e\n\u003cp\u003eThe measuring element is a \u003cstrong\u003eType J (Fe-CuNi)\u003c\/strong\u003e or \u003cstrong\u003eType K (NiCr-Ni)\u003c\/strong\u003e thermocouple, insulated in metal oxide. The operating range for Type J is from \u003cstrong\u003e-200 … +700 °C\u003c\/strong\u003e, for Type K from \u003cstrong\u003e-200 … +1000 °C\u003c\/strong\u003e. The limit deviation follows \u003cstrong\u003eDIN EN 60584-2 Class 1\u003c\/strong\u003e: \u003cstrong\u003e±1.5 °C\u003c\/strong\u003e in the range -40 … 375 °C, above that \u003cstrong\u003e±0.004|t|\u003c\/strong\u003e. The sensor directly outputs the thermovoltage; a transmitter is not documented; the insulation is tested with \u003cstrong\u003e500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The operating range is determined by the cable, not the sensor – PVC ends at \u003cstrong\u003e+70 °C\u003c\/strong\u003e, silicone at \u003cstrong\u003e+180 °C\u003c\/strong\u003e, PTFE at \u003cstrong\u003e+250 °C\u003c\/strong\u003e, glass silk at \u003cstrong\u003e+550 °C\u003c\/strong\u003e. If you want to utilize the +1000 °C of Type K, you will not find a suitable cable in this cable range; for PTFE, the sister sheets specify \u003cstrong\u003e+205 °C\u003c\/strong\u003e, the value from this source is adopted. IP 65 does not apply to the version with braided shield; the source does not specify which protection class applies there. The accuracy table extends further than the operating range: Type J is listed there up to 750 °C, in the operating range up to 700 °C. Terminal assignment, process connection, system pressure, weight, CE mark and explosion protection are not documented. Every order code begins with the product identifier \u003cstrong\u003eKB\u003c\/strong\u003e, the temperature range used must be specified in °C. The version with GL type approval is the \u003cstrong\u003eTBMB\u003c\/strong\u003e (TE-MK1G).\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eThermocouple Type J or Type K, -200 … +1000 °C\u003c\/li\u003e\n\n\u003cli\u003eLimit deviation Class 1 according to DIN EN 60584-2, ±1.5 °C from -40 °C\u003c\/li\u003e\n\n\u003cli\u003eFlexible sheathed tube, bending radius min. 5 × Ø protection tube\u003c\/li\u003e\n\n\u003cli\u003eFour diameters 1.5 · 3 · 4.5 · 6 mm, nominal length up to 2000 mm\u003c\/li\u003e\n\n\u003cli\u003eResponse time for Ø 3 mm t90 5 s and t50 2 s\u003c\/li\u003e\n\n\u003cli\u003eProtection tube 2.4816 (Inconel 600), material up to 1100 °C\u003c\/li\u003e\n\n\u003cli\u003eGL version available as TBMB (TE-MK1G)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356927435078,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TBMA_produkt_7a556a40-7d2f-4373-b0af-e6c840b05785.webp?v=1789243658"},{"product_id":"tkmd-widerstandsthermometer-mit-anschlusskopf-b-gl","title":"TKMD resistance thermometer with type B connection head, GL","description":"\u003cp\u003eThe \u003cstrong\u003eTKMD\u003c\/strong\u003e is a resistance thermometer with connection head B in the version with GL type approval, manufacturer type Müller \u003cstrong\u003eWT-MR1G\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is designed for fixed plant installation at measuring points where type approval is required: The manufacturer's data sheet shows the GL mark with the number \u003cstrong\u003eTAA00002H5\u003c\/strong\u003e. The aluminum \u003cstrong\u003econnection head\u003c\/strong\u003e accommodates a ceramic base with connection posts, the process connection at the head is \u003cstrong\u003eM24x1.5\u003c\/strong\u003e, the cable entry is \u003cstrong\u003eM20x1.5\u003c\/strong\u003e, and the protection class is \u003cstrong\u003eIP 54\u003c\/strong\u003e. The protection tube made of \u003cstrong\u003e1.4571 (316Ti)\u003c\/strong\u003e or \u003cstrong\u003e1.4401 (316)\u003c\/strong\u003e withstands \u003cstrong\u003eup to 600 °C\u003c\/strong\u003e, the process pressure is \u003cstrong\u003emax. PN16\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eCompared to the TKMC, this is not the same product with an additional mark: This version is limited to a length of \u003cstrong\u003e200 mm\u003c\/strong\u003e instead of 2000 mm and has a different sheath material and accessory kit. The source does not list a transmitter as an accessory here, but it does include connection cables up to 6 m, compression fittings, and sheet metal flanges. Screw-in (ES) and immersion (ET) designs are available, as well as protection tube diameters of \u003cstrong\u003e3 to 15 mm\u003c\/strong\u003e; the selection is limited for the sheathed element and in the immersion design.\u003c\/p\u003e\n\u003cp\u003eThe measuring element is a \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, single or double, in a \u003cstrong\u003e2-, 3- or 4-wire circuit\u003c\/strong\u003e, as a standard element or as a sheathed element. The sensor's operating range is \u003cstrong\u003e-200 ... +450 °C\u003c\/strong\u003e, and the accuracy ranges in five steps from \u003cstrong\u003eClass A to B1\/10DIN\u003c\/strong\u003e. The resistance is at the ceramic base in the head, the test voltage is \u003cstrong\u003e500 VDC\u003c\/strong\u003e, and the response time on the 3×0.4 mm tube is \u003cstrong\u003et90 5 s\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore ordering, please note:\u003c\/strong\u003e The approval is documented by a mark and number, not by a certificate – the manufacturer's data sheet does not name a certifying body, and the certificate is not available. The language versions contradict each other regarding the sheath material: The English page names 2.4816 (Inconel 600), while the German page and the order codes in both languages name \u003cstrong\u003e1.4401 (316)\u003c\/strong\u003e – 1.4401 applies here. A response time is missing for the other tube geometries. The ambient temperature is not the medium temperature: The head is limited to \u003cstrong\u003e480 °C\u003c\/strong\u003e, the element ends at \u003cstrong\u003e450 °C\u003c\/strong\u003e. IP 54 only applies to the connection head; the source does not specify a standard for the accuracy classes, and terminal assignment, CE mark, and explosion protection are missing. Both carry the product identification \u003cstrong\u003eKD\u003c\/strong\u003e, distinguished only by the first digit: \u003cstrong\u003e4 ... 7\u003c\/strong\u003e for the TKMD, 0 ... 3 for the \u003cstrong\u003eTKMC\u003c\/strong\u003e (WT-MR1) – the latter up to 2000 mm long and sheathed with 2.4816.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eGL type approval TAA00002H5, documented by mark and number\u003c\/li\u003e\n\n\u003cli\u003ePt100 or Pt1000, 2-, 3- or 4-wire circuit\u003c\/li\u003e\n\n\u003cli\u003eOperating range -200 ... +450 °C, Class A to B1\/10DIN\u003c\/li\u003e\n\n\u003cli\u003eProcess pressure max. PN16, installation lengths 50 to 200 mm\u003c\/li\u003e\n\n\u003cli\u003eProtection tube 1.4571 or 1.4401, Ø 3 to 15 mm, up to 600 °C\u003c\/li\u003e\n\n\u003cli\u003eConnection head B made of aluminum, IP 54, cable entry M20x1.5\u003c\/li\u003e\n\n\u003cli\u003eVersion without GL available as TKMC up to 2000 mm length\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356927467846,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TKMD_produkt_15586a12-ad89-4b0e-91b8-0781eec53f71.webp?v=1789243717"},{"product_id":"tcme-kabelfuehler-mit-passstueck","title":"TCME cable probe with adapter","description":"\u003cp\u003eThe \u003cstrong\u003eTCME\u003c\/strong\u003e is a resistance thermometer designed as a cable sensor with a fitting, manufacturer type Müller \u003cstrong\u003eWT-KH\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt measures where a mounting bore already exists: The \u003cstrong\u003efitting\u003c\/strong\u003e, a potted sleeve made of \u003cstrong\u003e1.4571\u003c\/strong\u003e, sits on the protective tube and guides the sensor precisely into the bore – no thread or flange is needed for this. You specify the diameter and length of the fitting, allowing the same sensor to fit an existing mounting. The protective tube made of \u003cstrong\u003e1.4571 (316Ti)\u003c\/strong\u003e is approved up to \u003cstrong\u003e600 °C\u003c\/strong\u003e and is available in \u003cstrong\u003eØ 4, 5, or 6 mm\u003c\/strong\u003e, with nominal lengths between 25 and 65 mm, or up to \u003cstrong\u003e2000 mm\u003c\/strong\u003e upon request. The protection class is \u003cstrong\u003eIP 65 up to 250 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt does not have a terminal compartment or electronics: The resistance value is directly available at open, bare ends of 70 mm, and the cable leads directly to the evaluation without an intermediate stage. A transmitter is not documented, therefore no current signal and no power supply either.\u003c\/p\u003e\n\u003cp\u003eMeasurements are taken with a \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, single or double, in \u003cstrong\u003e2-, 3- or 4-wire circuit\u003c\/strong\u003e and without insulation material. The sensor's operating range extends from \u003cstrong\u003e-200 ... +450 °C\u003c\/strong\u003e, and the accuracy can be ordered in five grades from \u003cstrong\u003eClass A to B1\/10DIN\u003c\/strong\u003e. For insulation, the manufacturer specifies a \u003cstrong\u003etest voltage of 500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore ordering, please note:\u003c\/strong\u003e The fitting is not a documented sealing element – the data sheet does not specify system pressure, sealing effect, or installation tolerance; anyone wishing to seal against a medium with it will need written confirmation. The operating range is determined by the cable, not the sensor: PVC only withstands \u003cstrong\u003e-5 ... +70 °C\u003c\/strong\u003e, glass fiber \u003cstrong\u003e-60 ... +550 °C\u003c\/strong\u003e – and the cable is in an environment that is not the medium temperature. \u003cstrong\u003eIP 65 does not apply to the version with screen braiding\u003c\/strong\u003e; what applies there is not stated in the sheet. The nominal length for Ø 4 mm is stated twice differently in the manufacturer's sheet, with 25 and with 35 mm; \u003cstrong\u003e25 mm\u003c\/strong\u003e has been adopted – please specify the length in plain text, as well as the temperature range in °C. The source does not specify a standard for the accuracy classes; CE marks and explosion protection are not documented, and this version does not carry a type approval – the version with \u003cstrong\u003eGL TAA00002H5\u003c\/strong\u003e is the \u003cstrong\u003eTCMF\u003c\/strong\u003e (WT-KHG). Both carry the product identification \u003cstrong\u003eKV\u003c\/strong\u003e and are distinguished solely by the \"sensor element\" location: 0 ... 3 is the WT-KH, 4 ... 7 is the WT-KHG.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eFitting as a potted sleeve made of 1.4571, dimensions as specified\u003c\/li\u003e\n\n\u003cli\u003ePt100 or Pt1000, single or double, 2-, 3- or 4-wire circuit\u003c\/li\u003e\n\n\u003cli\u003eOperating range -200 ... +450 °C, Class A to B1\/10DIN\u003c\/li\u003e\n\n\u003cli\u003eProtective tube 1.4571 (316Ti), Ø 4, 5 or 6 mm, up to 2000 mm upon request\u003c\/li\u003e\n\n\u003cli\u003eFive cable constructions from PVC to glass fiber, -5 ... +550 °C\u003c\/li\u003e\n\n\u003cli\u003eIP 65 up to 250 °C, not with screen braiding\u003c\/li\u003e\n\n\u003cli\u003eGL version available as TCMF (WT-KHG)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356927631686,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TCME_produkt_4115078f-819b-4be9-825b-82c9c45b783f.webp?v=1789243684"},{"product_id":"tbmb-mantel-thermoelement-gl","title":"TBMB mineral insulated thermocouple, GL","description":"\u003cp\u003eThe \u003cstrong\u003eTBMB\u003c\/strong\u003e is a sheathed thermocouple with GL type approval, manufacturer type Müller \u003cstrong\u003eTE-MK1G\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is designed for systems where the sensor must have type approval from Germanischer Lloyd: \u003cstrong\u003eGL TAA00002H3\u003c\/strong\u003e. Technically, it is the sensor of the \u003cstrong\u003eTE-MK1\u003c\/strong\u003e, but more narrowly defined – the nominal length is limited to \u003cstrong\u003e200 mm\u003c\/strong\u003e, and the connection cable to \u003cstrong\u003e6 m\u003c\/strong\u003e. The sheath remains flexible with a minimum bending radius of \u003cstrong\u003e5 × Ø protection tube\u003c\/strong\u003e, reaching installation locations that a rigid protection tube cannot; the cable is firmly attached to the sensor, eliminating the need for a connection head. Protection tube \u003cstrong\u003e2.4816\u003c\/strong\u003e (Inconel 600) and connection sleeve \u003cstrong\u003e1.4571\u003c\/strong\u003e (316Ti) provide \u003cstrong\u003eIP 65\u003c\/strong\u003e up to \u003cstrong\u003e250 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eDiameters and wall thicknesses are specified as \u003cstrong\u003e1.9×0.2\u003c\/strong\u003e, \u003cstrong\u003e3×0.25\u003c\/strong\u003e, \u003cstrong\u003e4.5×0.36\u003c\/strong\u003e, and \u003cstrong\u003e6×0.51 mm\u003c\/strong\u003e, with a standard nominal length of \u003cstrong\u003e100 mm\u003c\/strong\u003e. Connection is made via open ends or via TE connectors in standard or mini form; five cable types from PVC to glass fiber are available. Clamp fittings and sheet metal flanges from the accessories are used for fastening.\u003c\/p\u003e\n\u003cp\u003eThe measuring element is a thermocouple \u003cstrong\u003eType J (Fe-CuNi)\u003c\/strong\u003e or \u003cstrong\u003eType K (NiCr-Ni)\u003c\/strong\u003e, insulated in metal oxide. The operating range for Type J is from \u003cstrong\u003e-200 … +700 °C\u003c\/strong\u003e, and for Type K from \u003cstrong\u003e-200 … +1000 °C\u003c\/strong\u003e. The limit deviation follows \u003cstrong\u003eDIN EN 60584-2 Class 1\u003c\/strong\u003e: \u003cstrong\u003e±1.5 °C\u003c\/strong\u003e in the range -40 … 375 °C, and above that \u003cstrong\u003e±0.004|t|\u003c\/strong\u003e. The sensor outputs the thermovoltage directly; a transmitter is not documented; the insulation is tested with \u003cstrong\u003e500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e The approval is proven by a mark and number, not by a certificate; the certificate should be requested before any assurance is given to the classification society. Both versions carry the product designation \u003cstrong\u003eKB\u003c\/strong\u003e; they are distinguished solely by the thermocouple type digit: \u003cstrong\u003e2 · 3\u003c\/strong\u003e is the TE-MK1G, \u003cstrong\u003e0 · 1\u003c\/strong\u003e is the TE-MK1 – a digit swap orders the sensor without approval. The operating range is determined by the cable, not the sensor: PVC ends at +70 °C, silicone at +180 °C, PTFE at +250 °C, glass fiber at +550 °C; for PTFE, the sister sheets state +205 °C. IP 65 does not apply to the version with braided shield. Terminal assignment, process connection, system pressure, weight, response time, CE mark, and explosion protection are not documented. The version without approval, with a nominal length of \u003cstrong\u003e2000 mm\u003c\/strong\u003e, is the \u003cstrong\u003eTBMA\u003c\/strong\u003e (TE-MK1).\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eType approval GL TAA00002H3 proven by mark and number\u003c\/li\u003e\n\n\u003cli\u003eThermocouple Type J or Type K, -200 … +1000 °C\u003c\/li\u003e\n\n\u003cli\u003eLimit deviation Class 1 according to DIN EN 60584-2, ±1.5 °C from -40 °C\u003c\/li\u003e\n\n\u003cli\u003eFlexible sheath, bending radius min. 5 × Ø protection tube\u003c\/li\u003e\n\n\u003cli\u003eFour diameters with wall thickness: 1.9×0.2 to 6×0.51 mm\u003c\/li\u003e\n\n\u003cli\u003eNominal length 100 mm as standard, maximum 200 mm\u003c\/li\u003e\n\n\u003cli\u003eProtection tube 2.4816 (Inconel 600), connection cable maximum 6 m\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356927729990,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TBMB_produkt_38995495-5526-44d4-9bde-7f3262e5d4e4.webp?v=1789243659"},{"product_id":"temb-einschraub-temperatursensor-pt100","title":"TEMB screw-in temperature sensor, Pt100","description":"\u003cp\u003eThe \u003cstrong\u003eTEMB\u003c\/strong\u003e is a screw-in temperature sensor with Pt100, measuring amplifier, display, and two limit contacts, manufacturer type Müller \u003cstrong\u003eMETS-WS\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is screwed directly into pipes, tanks or units and measures, displays, and switches, without additional electronics in the control cabinet – one device at the process, one signal to the control system, one value to read on site. The protective tube is made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e in standard dimensions Ø 6 × 0.5 mm; with \u003cstrong\u003ePN 25\u003c\/strong\u003e, at least \u003cstrong\u003eIP 65\u003c\/strong\u003e and potted circuit boards, the device weighs approximately \u003cstrong\u003e150 g\u003c\/strong\u003e, and the mounting position is arbitrary.\u003c\/p\u003e\n\u003cp\u003eThe measured value remains readable on site: The display is 4-digit, 8.5 mm high and red, \u003cstrong\u003ereversible by 180°\u003c\/strong\u003e, the head is \u003cstrong\u003erotatable by 330°\u003c\/strong\u003e. Operation is via \u003cstrong\u003ethree buttons (TouchM)\u003c\/strong\u003e. The \u003cstrong\u003etwo limit contacts\u003c\/strong\u003e operate as PNP or NPN with 30 VDC \/ 200 mA, optionally 1000 mA; switching delay and failsafe are adjustable from 0.0 … 999.9 s.\u003c\/p\u003e\n\u003cp\u003eMeasurement is performed with a \u003cstrong\u003ePt100 in 4-wire connection\u003c\/strong\u003e in class A, B or AA (B1\/3 DIN) in the range \u003cstrong\u003e-50 … +200 °C\u003c\/strong\u003e with a minimum span of 50 °C. The output is \u003cstrong\u003e4 … 20 mA\u003c\/strong\u003e in the 2-wire current loop; the accuracy is \u003cstrong\u003emax. 0.1 % of the measuring range\u003c\/strong\u003e plus sensor error at 24 bit resolution. The sensor is powered with \u003cstrong\u003e12 … 35 VDC from the current loop\u003c\/strong\u003e, reverse polarity protected and short-circuit proof.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore ordering, please note:\u003c\/strong\u003e The ambient temperature is not the medium temperature – the medium may be up to +200 °C warm, but the electronics in the head can only tolerate -40 … +85 °C; the manufacturer explicitly states for the series that temperatures above +85 °C can destroy the electronics. Two limit contacts are not available on every connector, but only on M12 five- and eight-pin, on MIL, and on the cable. Higher ranges up to 250 °C are only mentioned in the data sheet upon request. An admissible load of the current loop is not documented in the manufacturer's data sheet; if planning long lines, the value must be inquired there. For programming, the configurator \u003cstrong\u003eDEV-KMA\u003c\/strong\u003e with TrComm software is required. A CE mark is not documented in the manufacturer's data sheet, and a declaration of conformity is not available. Explosion protection is also not documented for this version; the Ex version is the \u003cstrong\u003eTEMD\u003c\/strong\u003e (METS-WTEx).\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eMeasures, displays, and switches – one device directly at the process\u003c\/li\u003e\n\n\u003cli\u003ePt100 in 4-wire connection, class A, B or AA (B1\/3 DIN)\u003c\/li\u003e\n\n\u003cli\u003eMedium -50 … +200 °C, accuracy max. 0.1 % of the measuring range\u003c\/li\u003e\n\n\u003cli\u003e4 … 20 mA in the 2-wire loop, 12 … 35 VDC from the loop\u003c\/li\u003e\n\n\u003cli\u003eDisplay 4-digit, reversible by 180°, head rotatable by 330°\u003c\/li\u003e\n\n\u003cli\u003eTwo limit contacts, PNP or NPN, 30 VDC \/ 200 mA\u003c\/li\u003e\n\n\u003cli\u003eProtective tube 1.4571, system pressure PN 25, at least IP 65\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356927795526,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TEMB_produkt_438e052b-090e-4e49-80cd-c78da69aa64b.webp?v=1789243685"},{"product_id":"tcmf-kabelfuehler-mit-passstueck-gl","title":"TCMF cable probe with adapter, GL","description":"\u003cp\u003eThe \u003cstrong\u003eTCMF\u003c\/strong\u003e is a cable sensor with a fitting piece in the GL type-approved version, manufacturer type Müller \u003cstrong\u003eWT-KHG\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt measures where a mounting bore is already present and type approval is also required: The \u003cstrong\u003efitting piece\u003c\/strong\u003e, a cast sleeve made of \u003cstrong\u003e1.4571\u003c\/strong\u003e, sits on the protective tube and guides the sensor precisely into the bore – a thread or a flange is not necessary for this; you specify the diameter and length. The protective tube made of \u003cstrong\u003e1.4571 (316Ti)\u003c\/strong\u003e is approved up to \u003cstrong\u003e600 °C\u003c\/strong\u003e and is available in \u003cstrong\u003eØ 4, 5, or 6 mm\u003c\/strong\u003e; the nominal lengths are between 25 and 65 mm. The protection class is \u003cstrong\u003eIP 65 up to 250 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt differs from the TCME by its type approval: The manufacturer's sheet shows the GL mark with the number \u003cstrong\u003eGL TAA00002H5\u003c\/strong\u003e. For this, this version is shorter – the maximum length is \u003cstrong\u003e200 mm\u003c\/strong\u003e instead of 2000 mm, and the cable is at most \u003cstrong\u003e6 m\u003c\/strong\u003e. It also does not have a terminal compartment or electronics: The resistance value is directly at open, bare ends of 70 mm; a transmitter is not documented. \u003c\/p\u003e\n\u003cp\u003eMeasurements are taken with a \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, single or double, in \u003cstrong\u003e2-, 3-, or 4-wire configuration\u003c\/strong\u003e and without insulating material. The sensor's operating range extends from \u003cstrong\u003e-200 ... +450 °C\u003c\/strong\u003e; the accuracy can be ordered in five stages from \u003cstrong\u003eClass A to B1\/10DIN\u003c\/strong\u003e. For insulation, the manufacturer specifies a \u003cstrong\u003etest voltage of 500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e The approval is documented as a mark and number, not as a certificate – the manufacturer's sheet does not name a certifying body, and we do not have the certificate itself; it should be requested before making an assurance to a classification society. The fitting piece is not a documented sealing element: The datasheet does not specify system pressure, sealing effect, or installation tolerance. The operating range is determined by the cable, not the sensor – PVC only withstands \u003cstrong\u003e-5 ... +70 °C\u003c\/strong\u003e, glass fiber \u003cstrong\u003e-60 ... +550 °C\u003c\/strong\u003e, and the cable is in the environment, which is not the medium temperature. Terminal assignment is not documented, neither wire color nor terminal number. The source does not specify a standard for the accuracy classes; CE mark and explosion protection are not documented. Both versions carry the product identification \u003cstrong\u003eKV\u003c\/strong\u003e and are distinguished solely by the \"sensor element\" location: 4 ... 7 is the WT-KHG, 0 ... 3 is the WT-KH.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eGL type approval TAA00002H5 documented in the manufacturer's sheet\u003c\/li\u003e\n\n\u003cli\u003eFitting piece as a cast sleeve made of 1.4571, dimensions according to specification\u003c\/li\u003e\n\n\u003cli\u003ePt100 or Pt1000, 2-, 3- or 4-wire configuration\u003c\/li\u003e\n\n\u003cli\u003eOperating range -200 ... +450 °C, Class A to B1\/10DIN\u003c\/li\u003e\n\n\u003cli\u003eProtective tube 1.4571 (316Ti), Ø 4, 5 or 6 mm, maximum nominal length 200 mm\u003c\/li\u003e\n\n\u003cli\u003eCable in standard 2 m, maximum 6 m\u003c\/li\u003e\n\n\u003cli\u003eVersion without GL available up to 2000 mm as TCME (WT-KH)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356928155974,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TCMF_produkt_7c87b86b-2304-44d6-bb0d-0da994943bf3.webp?v=1789243684"},{"product_id":"temc-einschraub-temperatursensor-hart","title":"TEMC screw-in temperature sensor, HART","description":"\u003cp\u003eThe \u003cstrong\u003eTEMC\u003c\/strong\u003e is a screw-in temperature sensor with Pt100 and a HART-enabled measuring transducer, manufacturer type Müller \u003cstrong\u003eMETS-WT\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is screwed directly into the pipe, tank or unit and measures where the temperature originates. The thermowell is made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e with standard dimensions Ø 6 × 0.5 mm, the housing body is made of PBT GF30; with \u003cstrong\u003ePN 25\u003c\/strong\u003e, at least \u003cstrong\u003eIP 65\u003c\/strong\u003e and encapsulated circuit boards, the device can be mounted in any position on the process, a 100 mm neck tube is available as an option.\u003c\/p\u003e\n\u003cp\u003eIt is the slim version of the series: no display, no buttons, no limit value contacts. It is intended for systems where the evaluation is done in the control room anyway and only measurement and transmission take place at the process. The electrical connection is on the side, optionally on the top – this determines the space next to the process connection.\u003c\/p\u003e\n\u003cp\u003eMeasurements are taken with a \u003cstrong\u003ePt100 in a 2-wire circuit\u003c\/strong\u003e in Class A, B or AA (B1\/3 DIN) in the range \u003cstrong\u003e-50 … +200 °C\u003c\/strong\u003e with a minimum span of 50 °C. The output is \u003cstrong\u003e4 … 20 mA with superimposed HART signal\u003c\/strong\u003e in the 2-wire current loop, temperature-linear; the accuracy is \u003cstrong\u003e0.3 % of the range\u003c\/strong\u003e at 16 bit resolution, the measurement rate is 10 measurements per second. The sensor is supplied with \u003cstrong\u003e12 … 40 VDC from the current loop\u003c\/strong\u003e, with reverse polarity protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e The ambient temperature is not the medium temperature – the medium may be up to +200 °C, the electronics in the head only -20 … +80 °C. The manufacturer's note states +85 °C, the characteristic values of this sheet only +80 °C; the lower value should be used for design. Without the configurator, this product cannot be adjusted: it has neither display nor buttons, any change to the measuring range requires the \u003cstrong\u003eDEV-KMA\u003c\/strong\u003e and the TrComm software. A permissible burden of the current loop is not documented in the manufacturer's data sheet – for HART in long cables, the value should be requested there. Higher ranges are not mentioned in this data sheet. A CE mark is not documented in the manufacturer's data sheet, a declaration of conformity is not available. Explosion protection is not documented; the Ex version is the \u003cstrong\u003eTEMD\u003c\/strong\u003e (METS-WTEx), the version with display and two limit value contacts is the \u003cstrong\u003eTEMB\u003c\/strong\u003e (METS-WS).\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003ePt100 in 2-wire circuit, Class A, B or AA (B1\/3 DIN)\u003c\/li\u003e\n\n\u003cli\u003eMedium -50 … +200 °C, minimum span 50 °C\u003c\/li\u003e\n\n\u003cli\u003e4 … 20 mA with superimposed HART in the 2-wire loop\u003c\/li\u003e\n\n\u003cli\u003eAccuracy 0.3 % of range, 16 bit, 10 measurements per second\u003c\/li\u003e\n\n\u003cli\u003eSupply 12 … 40 VDC from the loop, with reverse polarity protection\u003c\/li\u003e\n\n\u003cli\u003eElectrical connection optionally lateral or top\u003c\/li\u003e\n\n\u003cli\u003eThermowell 1.4571, system pressure PN 25, at least IP 65\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356928254278,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TEMC_produkt_b35d1c31-6caf-4569-a05f-42e01f25278c.webp?v=1789243685"},{"product_id":"tbmc-mantel-widerstandsthermometer","title":"TBMC mineral insulated resistance thermometer","description":"\u003cp\u003eThe \u003cstrong\u003eTBMC\u003c\/strong\u003e is a sheathed resistance thermometer with a flexible protective tube and fixed connection cable, manufacturer type Müller \u003cstrong\u003eWT-MK1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt measures in installation locations that a rigid protective tube cannot reach, and where a class better than a thermocouple is required. The sheathed tube can be bent to a radius of \u003cstrong\u003emin. 5 × Ø protective tube\u003c\/strong\u003e; the cable is firmly attached to the sensor, eliminating the need for a connection head. Protective tube \u003cstrong\u003e1.4401\u003c\/strong\u003e (316), specified as a material up to \u003cstrong\u003e600 °C\u003c\/strong\u003e, and connecting sleeve \u003cstrong\u003e1.4571\u003c\/strong\u003e (316Ti) provide \u003cstrong\u003eIP 65\u003c\/strong\u003e up to \u003cstrong\u003e250 °C\u003c\/strong\u003e. Available in \u003cstrong\u003e3 · 4.5 · 6 mm\u003c\/strong\u003e diameters with a wall thickness of 0.25 to 0.51 mm, the standard nominal length is \u003cstrong\u003e100 mm\u003c\/strong\u003e, up to \u003cstrong\u003e2000 mm\u003c\/strong\u003e on request. Compression fittings and sheet metal flanges are available as accessories.\u003c\/p\u003e\n\u003cp\u003eThe sensor is sluggish: for \u003cstrong\u003e6×0.5 mm\u003c\/strong\u003e, the manufacturer states \u003cstrong\u003et90 30.9 s\u003c\/strong\u003e and t50 12 s; for \u003cstrong\u003e6×1 mm\u003c\/strong\u003e, \u003cstrong\u003et90 22.1 s\u003c\/strong\u003e and t50 7.6 s. Connection is via open ends with wire end ferrules; five cable types from PVC to glass silk are available.\u003c\/p\u003e\n\u003cp\u003eThe measuring element is a \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, single or double, insulated in metal oxide and wired in \u003cstrong\u003e2-, 3- or 4-wire\u003c\/strong\u003e configuration. The sensor's operating range extends from \u003cstrong\u003e-200 ... +450 °C\u003c\/strong\u003e, with accuracy selectable in five stages from \u003cstrong\u003eClass A\u003c\/strong\u003e to \u003cstrong\u003eB1\/10DIN\u003c\/strong\u003e. The sensor outputs the resistance directly; a transmitter is not documented; insulation is tested with \u003cstrong\u003e500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore ordering, please note:\u003c\/strong\u003e The operating range is determined by the cable, not the sensor – PVC ends at \u003cstrong\u003e+70 °C\u003c\/strong\u003e, silicone at \u003cstrong\u003e+180 °C\u003c\/strong\u003e, PTFE at \u003cstrong\u003e+205 °C\u003c\/strong\u003e, glass silk at \u003cstrong\u003e+550 °C\u003c\/strong\u003e; only the glass silk version reaches the +450 °C of the sensor. Two four-wire sensors are only available with PTFE-silicone cable, so this version ends at +180 °C. The source does not specify any standard for the accuracy classes – if a class needs to be guaranteed, it must be confirmed by the manufacturer. The two response times contradict each other: the thicker 6×1 mm wall is stated as faster, and 1 mm is not in the wall thickness table. IP 65 does not apply to the version with braided shielding. Terminal assignment, process connection, system pressure, weight, CE mark, and explosion protection are not documented. Each order code begins with the product identifier \u003cstrong\u003eKM\u003c\/strong\u003e, the used temperature range must be specified in °C. The version with GL type approval is the \u003cstrong\u003eTBMD\u003c\/strong\u003e (WT-MK1G).\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003ePt100 or Pt1000, single or double, -200 ... +450 °C\u003c\/li\u003e\n\n\u003cli\u003eWiring in 2-, 3- or 4-wire freely selectable\u003c\/li\u003e\n\n\u003cli\u003eFive accuracy classes from Class A to B1\/10DIN\u003c\/li\u003e\n\n\u003cli\u003eFlexible sheathed tube, bending radius min. 5 × Ø protective tube\u003c\/li\u003e\n\n\u003cli\u003eThree diameters 3 · 4.5 · 6 mm, nominal length up to 2000 mm\u003c\/li\u003e\n\n\u003cli\u003eProtective tube 1.4401 (316), material up to 600 °C\u003c\/li\u003e\n\n\u003cli\u003eGL version available as TBMD (WT-MK1G)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356928319814,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TBMC_produkt_72d26594-15bb-4ddd-b26c-1ce689988940.webp?v=1789243659"},{"product_id":"temd-einschraub-temperatursensor-ex","title":"TEMD screw-in temperature sensor, Ex","description":"\u003cp\u003eThe \u003cstrong\u003eTEMD\u003c\/strong\u003e is a screw-in temperature sensor in an intrinsically safe design, manufacturer type Müller \u003cstrong\u003eMETS-WTEx\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is the Ex version of the series and is designed for installation in potentially explosive areas with gases. It is screwed directly into pipes, tanks, or units; the protective tube is made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, the system pressure is \u003cstrong\u003ePN 25\u003c\/strong\u003e, and the protection class is at least \u003cstrong\u003eIP 65\u003c\/strong\u003e. Compared to the other screw-in sensors in the series, it goes significantly higher in the medium: up to \u003cstrong\u003e+425 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt has no display, buttons, or limit contacts; the measured value is sent as a current or voltage signal for evaluation, and settings are made with the \u003cstrong\u003eDEV-KMA\u003c\/strong\u003e configurator and TrComm software.\u003c\/p\u003e\n\u003cp\u003eMeasurements are taken with a \u003cstrong\u003ePt100 in a 2-wire circuit\u003c\/strong\u003e in Class A, B, or AA in the range of \u003cstrong\u003e-50 … +425 °C\u003c\/strong\u003e with a minimum span of 50 °C. The output offers a choice between \u003cstrong\u003e4 … 20 mA\u003c\/strong\u003e in 2-wire technology and \u003cstrong\u003evoltage signals such as 0 … 10 V\u003c\/strong\u003e in 3-wire technology. The accuracy is \u003cstrong\u003emax. 0.1 % of the measuring range\u003c\/strong\u003e plus sensor error at 24-bit resolution, powered by \u003cstrong\u003e12 … 30 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The data sheet specifies installation for gases in \u003cstrong\u003eZone 0, Zone 1, and Zone 2\u003c\/strong\u003e and lists three markings: \u003cstrong\u003eII 1 G Ex ia IIC T6..T1 Ga\u003c\/strong\u003e, \u003cstrong\u003eII 1\/2 G Ex ia IIC T6..T1 Ga\/Gb\u003c\/strong\u003e, and \u003cstrong\u003eII 2 G Ex ia IIC T6..T1 Gb\u003c\/strong\u003e; it does not explicitly state which marking is assigned to which zone. The certifications are \u003cstrong\u003eTÜV 21 ATEX 201293 X\u003c\/strong\u003e according to directive \u003cstrong\u003e2014\/34\/EU\u003c\/strong\u003e and \u003cstrong\u003eIECEx TUN 21.0005X\u003c\/strong\u003e. Both approval numbers end in X, which means special conditions apply; these are found in the operating instructions and not in the data sheet. The temperature class is given as T6..T1, not as a single value; according to the data sheet, the applicable class depends on the installation. The ambient temperature depends on the output type: -20 … +75 °C is permissible for the 2-wire current output, but only -20 … +50 °C for the 3-wire voltage output – anyone who orders the voltage output and designs for the upper value will be 25 K too high. And the ambient temperature is not the medium temperature: The medium can be up to +425 °C, but the electronics in the head cannot – above +85 °C, they can be destroyed. A CE mark is not documented in the data sheet, and a declaration of conformity is not available. The version without explosion protection, with display and two limit contacts, is the \u003cstrong\u003eTEMB\u003c\/strong\u003e (METS-WS).\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a Glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eIntrinsically safe, marking II 1 G Ex ia IIC T6..T1 Ga\u003c\/li\u003e\n\n\u003cli\u003eATEX TÜV 21 ATEX 201293 X and IECEx TUN 21.0005X\u003c\/li\u003e\n\n\u003cli\u003eInstallation for gases in Zone 0, Zone 1, and Zone 2\u003c\/li\u003e\n\n\u003cli\u003ePt100 in 2-wire circuit, medium -50 … +425 °C\u003c\/li\u003e\n\n\u003cli\u003eAccuracy max. 0.1 % of measuring range, 24-bit resolution\u003c\/li\u003e\n\n\u003cli\u003e4 … 20 mA in 2-wire or 0 … 10 V in 3-wire technology\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356928418118,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TEMD_produkt_f90bbf88-8064-40a9-86cc-c3af619fcca9.webp?v=1789243685"},{"product_id":"tbmd-mantel-widerstandsthermometer-gl","title":"TBMD mineral insulated resistance thermometer, GL","description":"\u003cp\u003eThe \u003cstrong\u003eTBMD\u003c\/strong\u003e is a sheathed resistance thermometer with GL type approval, manufacturer type Müller \u003cstrong\u003eWT-MK1G\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is designed for systems where the sensor must carry a type approval from Germanischer Lloyd: \u003cstrong\u003eGL TAA00002H5\u003c\/strong\u003e. Compared to the \u003cstrong\u003eWT-MK1\u003c\/strong\u003e, the nominal length is limited to \u003cstrong\u003e200 mm\u003c\/strong\u003e and the connection cable to \u003cstrong\u003e6 m\u003c\/strong\u003e, but there is an additional diameter of \u003cstrong\u003e1.9 mm\u003c\/strong\u003e, which also fits into narrow boreholes. The sheath remains flexible with a minimum bending radius of \u003cstrong\u003e5 × Ø protection tube\u003c\/strong\u003e and reaches installation locations that a rigid protection tube cannot; the cable is fixed, and no connection head is required.\u003c\/p\u003e\n\u003cp\u003eProtection tube \u003cstrong\u003e1.4401\u003c\/strong\u003e (316), specified as a material up to \u003cstrong\u003e600 °C\u003c\/strong\u003e, and connection sleeve \u003cstrong\u003e1.4571\u003c\/strong\u003e (316Ti) carry \u003cstrong\u003eIP 65\u003c\/strong\u003e up to \u003cstrong\u003e250 °C\u003c\/strong\u003e; the nominal length is standard at \u003cstrong\u003e100 mm\u003c\/strong\u003e. Connection is made via open ends with wire end ferrules; five cable versions from PVC to glass silk are available. Compression fittings and sheet metal flanges are accessories.\u003c\/p\u003e\n\u003cp\u003eThe measuring element is a \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, single or double, insulated in metal oxide and wired in \u003cstrong\u003e2-, 3- or 4-wire\u003c\/strong\u003e circuitry. The sensor's operating range extends from \u003cstrong\u003e-200 to +450 °C\u003c\/strong\u003e, and accuracy can be selected in five steps from \u003cstrong\u003eClass A\u003c\/strong\u003e to \u003cstrong\u003eB1\/10DIN\u003c\/strong\u003e. The sensor outputs resistance directly; a transmitter is not documented; insulation is tested with \u003cstrong\u003e500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e The approval is documented as a mark and number, not as a certificate; the certificate should be requested before any assurance is given to the classification society. Both versions bear the product identification \u003cstrong\u003eKM\u003c\/strong\u003e; they are distinguished solely by the sensor element position: \u003cstrong\u003e4 ... 7\u003c\/strong\u003e is the WT-MK1G, \u003cstrong\u003e0 ... 3\u003c\/strong\u003e is the WT-MK1 - a digit reversal orders the sensor without approval. The operating range is determined by the cable, not the sensor: PVC ends at +70 °C, silicone at +180 °C, PTFE at +205 °C, glass silk at +550 °C - only the glass silk version reaches the sensor's +450 °C. The source does not specify a standard for the accuracy classes. IP 65 does not apply to the version with braided shield. Wall thickness, terminal assignment, process connection, system pressure, weight, response time, CE mark, and explosion protection are not documented. The version without approval, with a nominal length of \u003cstrong\u003e2000 mm\u003c\/strong\u003e, is the \u003cstrong\u003eTBMC\u003c\/strong\u003e (WT-MK1).\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eType approval GL TAA00002H5 documented as a mark and number\u003c\/li\u003e\n\n\u003cli\u003ePt100 or Pt1000, single or double, -200 ... +450 °C\u003c\/li\u003e\n\n\u003cli\u003eCircuitry in 2-, 3- or 4-wire, Class A to B1\/10DIN\u003c\/li\u003e\n\n\u003cli\u003eFour diameters 1.9 · 3 · 4.5 · 6 mm, one more than the TBMC\u003c\/li\u003e\n\n\u003cli\u003eFlexible sheath, bending radius min. 5 × Ø protection tube\u003c\/li\u003e\n\n\u003cli\u003eNominal length 100 mm as standard, maximum 200 mm\u003c\/li\u003e\n\n\u003cli\u003eProtection tube 1.4401 (316), connection cable maximum 6 m\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356928549190,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TBMD_produkt_9be15878-5282-42b0-bac6-38484c92125f.webp?v=1789243659"},{"product_id":"tfmb-oberflaechen-temperatursensor-auf-haftmagnet-mit-funkuebertragung","title":"TFMB surface temperature sensor on magnet, wireless","description":"\u003cp\u003eThe \u003cstrong\u003eTFMB\u003c\/strong\u003e is a surface temperature sensor with radio transmission on a magnetic base, manufacturer type Müller \u003cstrong\u003eMETS-WRM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is attached, not installed: The \u003cstrong\u003eAlnico 500\u003c\/strong\u003e magnetic base holds it with \u003cstrong\u003e66 N\u003c\/strong\u003e on pipes, motors, and housings where neither drilling nor cabling is possible. The spring-loaded measuring surface \u003cstrong\u003eØ 6 mm\u003c\/strong\u003e with 1.5 mm travel presses onto the surface, and the sensor body is made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e. At approximately \u003cstrong\u003e514 g\u003c\/strong\u003e and at least \u003cstrong\u003eIP 65\u003c\/strong\u003e for the electronics, the mounting position is arbitrary.\u003c\/p\u003e\n\u003cp\u003eThere is no signal cable: The measured value is transmitted wirelessly in the \u003cstrong\u003eSRD band 868 MHz\u003c\/strong\u003e with FSK. The range is \u003cstrong\u003e20 m\u003c\/strong\u003e with an internal antenna and \u003cstrong\u003e100 m\u003c\/strong\u003e with an external antenna, each with a clear line of sight. The sensor is powered by a \u003cstrong\u003e3.6 V \/ 2600 mAh lithium-ion battery\u003c\/strong\u003e, optionally continuously with 24 VDC; the standby time is approx. \u003cstrong\u003e6 months\u003c\/strong\u003e for one measurement per minute and approx. 50 days for six measurements per minute. It is switched on and off with a magnet on top of the lid, and two LEDs indicate the status.\u003c\/p\u003e\n\u003cp\u003eMeasurements are taken with a \u003cstrong\u003ePt100 in a 4-wire circuit, Class A\u003c\/strong\u003e with 16 bits and a step size of \u003cstrong\u003e0.1 °C\u003c\/strong\u003e. The maximum range extends from \u003cstrong\u003e-50 … +400 °C\u003c\/strong\u003e, the factory setting is -50 … 250 °C according to the order key. The measurement rate is 8 measurements per second, and the accuracy is \u003cstrong\u003e0.15 % of the range\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The data sheet states the accuracy as 0.15 % of the range, while the feature list on the first page indicates approx. 0.2 %; the data sheet is decisive. The ambient temperature is not the medium temperature – the measuring surface can withstand up to +400 °C, but the electronics in the head only up to \u003cstrong\u003e+60 °C\u003c\/strong\u003e, and the sensor with the magnet is placed directly on the hot surface; the data sheet does not specify how much heat reaches the head in this process. The range applies to clear line of sight: Walls, metal, and system components shorten it, but by how much, the data sheet does not say – and the magnet places the sensor directly on metal. The battery only charges between 0 and +45 °C, but operation is possible up to +60 °C; above this, measurements can be taken, but the battery cannot be charged. For reading out and remote configuration, the USB transceiver \u003cstrong\u003eUSB-RC\u003c\/strong\u003e (700-00122) is required. A CE mark, a declaration of conformity, a radio approval number, and explosion protection are not documented in the data sheet.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eAttached instead of installed – magnetic base with 66 N made of Alnico 500\u003c\/li\u003e\n\n\u003cli\u003eSpring-loaded measuring surface Ø 6 mm, Pt100 4-wire, Class A, up to +400 °C\u003c\/li\u003e\n\n\u003cli\u003eWireless in the SRD band 868 MHz, 20 m internal, 100 m external with clear line of sight\u003c\/li\u003e\n\n\u003cli\u003eAccuracy 0.15 % of the range, 16 bits, step size 0.1 °C\u003c\/li\u003e\n\n\u003cli\u003eBattery 3.6 V \/ 2600 mAh, standby time approx. 6 months at 1 measurement per minute\u003c\/li\u003e\n\n\u003cli\u003eSensor body 1.4571, at least IP 65, system pressure PN 25\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356928647494,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TFMB_produkt_7a92928e-eb13-44e3-bdcb-aaacdd393597.webp?v=1789243685"},{"product_id":"tlma-temperaturschalter-bimetall","title":"TLMA bimetal temperature switch","description":"\u003cp\u003eThe \u003cstrong\u003eTLMA\u003c\/strong\u003e is a temperature switch with a bimetallic trigger, manufacturer type Müller \u003cstrong\u003eMKTL\u003c\/strong\u003e. It does not output a measured value but opens a contact as soon as the set temperature is reached.\u003c\/p\u003e\n\u003cp\u003eIt is designed as a limiter for machines and devices – for switching off or for switching on cooling in mobile hydraulics, engines, and compressors. It sits directly in the medium, screwed in with pipe or NPT threads, or threadless as an immersion switch: protective tube Ø 9 × 0.5 mm made of stainless steel, housing body also made of stainless steel and potted internally, system pressure up to \u003cstrong\u003e100 bar\u003c\/strong\u003e, vibration resistance up to 10 g, shock resistance up to 100 g, protection class \u003cstrong\u003eat least IP 65\u003c\/strong\u003e with the connector plugged in. The installation length ranges from \u003cstrong\u003e50 to 1000 mm\u003c\/strong\u003e according to the order code.\u003c\/p\u003e\n\u003cp\u003eBecause the bimetallic trigger operates \u003cstrong\u003ewithout auxiliary energy\u003c\/strong\u003e, the switch requires neither a power supply nor evaluation electronics.\u003c\/p\u003e\n\u003cp\u003eThe switching element is a bimetallic trigger with \u003cstrong\u003e1 NC contact\u003c\/strong\u003e, creeping and \u003cstrong\u003ewithout hysteresis\u003c\/strong\u003e. The switching point is between \u003cstrong\u003e5 … 200 °C\u003c\/strong\u003e and is selected in steps of \u003cstrong\u003e1 °C\u003c\/strong\u003e, the accuracy is \u003cstrong\u003e±5 K\u003c\/strong\u003e, with an option of ±3 K on request; the medium can be between \u003cstrong\u003e0 … +200 °C\u003c\/strong\u003e. The contact switches \u003cstrong\u003e12 VDC at 8 A\u003c\/strong\u003e or \u003cstrong\u003e24 VDC at 4 A\u003c\/strong\u003e, the contact surface is gold-plated, and the switching contact is silver. This switching capacity applies to \u003cstrong\u003e5,000 switching cycles\u003c\/strong\u003e at 100 °C and ohmic load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The switching point is fixed at the factory, must be included in the order, and cannot be changed on-site – if you want to adjust it later, you will need a different device. The ambient temperature is not the medium temperature: The medium can be up to +200 °C, but the head only up to +85 °C. Below 0 °C, the product is not documented: medium, ambient, and storage temperatures all start at 0 °C. The permissible load depends on the chosen connector and is sometimes lower than the contact capacity – M12 eight-pin, for example, only 30 V and 2 A. The source only mentions \"stainless steel\" without a material number and specifies pressure, vibration, and shock values only dependent on the medium, temperature, installation position, and protective tube – these are maximum values, not a guarantee for every installation. A CE mark, explosion protection, and SIL or PL classification are not documented: as a safety limiter, the switch should only be used after your own assessment.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eBimetallic trigger, operates without auxiliary energy\u003c\/li\u003e\n\n\u003cli\u003eSwitching point 5 … 200 °C in steps of 1 °C, accuracy ±5 K\u003c\/li\u003e\n\n\u003cli\u003e1 NC contact, creeping, gold-plated contact surface\u003c\/li\u003e\n\n\u003cli\u003eSwitching capacity 12 VDC 8 A or 24 VDC 4 A\u003c\/li\u003e\n\n\u003cli\u003eProtective tube Ø 9 × 0.5 mm made of stainless steel, system pressure up to 100 bar\u003c\/li\u003e\n\n\u003cli\u003eInstallation length 50 to 1000 mm according to code, at least IP 65\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356931760454,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TLMA_produkt_d4881495-7838-4d3a-b621-5888e450bdc6.webp?v=1789243717"},{"product_id":"tlmb-temperatur-grenzwertschalter","title":"TLMB temperature limit switch","description":"\u003cp\u003eThe \u003cstrong\u003eTLMB\u003c\/strong\u003e is a temperature limit switch with Pt100 and relay output, manufacturer type Müller \u003cstrong\u003eMETL-L\u003c\/strong\u003e. It does not output a measured value, but switches a relay as soon as the limit value is reached.\u003c\/p\u003e\n\u003cp\u003eIt is screwed into pipes or tanks and switches there without an evaluation unit, for example directly to a digital input of a PLC. The process connection and protective tube are made of \u003cstrong\u003e1.4571\u003c\/strong\u003e, the protective tube measures Ø 6 mm as standard or Ø 9 mm; the insertion length ranges from \u003cstrong\u003e50 to 1000 mm\u003c\/strong\u003e according to the key, the system pressure is \u003cstrong\u003ePN 25\u003c\/strong\u003e. The housing body and lid are made of PBT GF30, the circuit boards are potted, and the protection class is \u003cstrong\u003eat least IP 65\u003c\/strong\u003e. The weight is approximately \u003cstrong\u003e140 g\u003c\/strong\u003e, and the mounting position is arbitrary.\u003c\/p\u003e\n\u003cp\u003eThe switching point is set \u003cstrong\u003eon site with a magnet\u003c\/strong\u003e: without tools and without opening the housing. Instead of a display, there is a red LED, \u003cstrong\u003e360° visible\u003c\/strong\u003e – it lights up as long as the relay is active.\u003c\/p\u003e\n\u003cp\u003eThe input has a \u003cstrong\u003ePt100 in 3-wire circuit\u003c\/strong\u003e of class \u003cstrong\u003eB\u003c\/strong\u003e, class A as an option, in the range of \u003cstrong\u003e-50 ... +200 °C\u003c\/strong\u003e with an accuracy of \u003cstrong\u003e±0.5 °C\u003c\/strong\u003e. The switching point is set to \u003cstrong\u003e100 °C\u003c\/strong\u003e ex works, the hysteresis is \u003cstrong\u003e0.1 °C\u003c\/strong\u003e as standard. The output is a \u003cstrong\u003erelay with changeover contact\u003c\/strong\u003e: 1 A at 30 VDC or 0.3 A at 125 VAC at resistive load, for \u003cstrong\u003emore than 100,000 switching cycles\u003c\/strong\u003e. The switch is powered by \u003cstrong\u003e24 ... 30 VDC\u003c\/strong\u003e at approx. 35 mA including the relay circuit; the electrical connection is \u003cstrong\u003eM12x1 eight-pole\u003c\/strong\u003e as the only option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The manufacturer's overview page contradicts the data sheet – it states an open collector with 30 V and 200 mA, the data sheet states a changeover relay with 1 A and ±0.5 °C. We use the values from the data sheet; the output type must be confirmed with the manufacturer before ordering. Measuring and configuring are not possible simultaneously: For HART, pin 5 is connected via a 250 Ω resistor, and in this connection, the relay is not functional. Only the switching point can be changed with the magnet; hysteresis, switching delay, and damping are only possible via the HART tool, interface \u003cstrong\u003eDEV-HM\u003c\/strong\u003e. The ambient temperature is not the medium temperature: The medium can be up to +200 °C, the electronics in the head only up to +80 °C. A CE mark, explosion protection, and SIL or PL classification are not documented.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003ePt100 3-wire, Class B, Class A as an option\u003c\/li\u003e\n\n\u003cli\u003eRange -50 to +200 °C, accuracy ±0.5 °C\u003c\/li\u003e\n\n\u003cli\u003eSwitching point set on-site with magnet\u003c\/li\u003e\n\n\u003cli\u003eChangeover relay 1 A at 30 VDC, more than 100,000 switching cycles\u003c\/li\u003e\n\n\u003cli\u003eRed LED, 360° visible\u003c\/li\u003e\n\n\u003cli\u003eProtective tube 1.4571, Ø 6 or Ø 9 mm, PN 25\u003c\/li\u003e\n\n\u003cli\u003eAt least IP 65, potted circuit boards, approx. 140 g\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356931825990,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TLMB_produkt_cbb01634-a42b-404a-a6b6-905e93e134d2.webp?v=1789243717"},{"product_id":"tmma-oberflaechen-temperatursensor-auf-haftmagnet-mit-anzeige","title":"TMMA surface temperature sensor on magnet, with display","description":"\u003cp\u003eThe \u003cstrong\u003eTMMA\u003c\/strong\u003e is a surface temperature sensor on a magnetic base with a display and two limit contacts, manufacturer type Müller \u003cstrong\u003eMETS-WSM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is placed on pipes, motors, and housings where no drilling is allowed – attached instead of installed, without interfering with the medium. The spring-loaded measuring surface \u003cstrong\u003eØ 6 mm\u003c\/strong\u003e with 1.5 mm travel presses onto the surface, and the Alnico 500 magnetic base holds with \u003cstrong\u003e66 N\u003c\/strong\u003e. The sensor body is made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e; with approx. \u003cstrong\u003e259 g\u003c\/strong\u003e, \u003cstrong\u003ePN 25\u003c\/strong\u003e and at least \u003cstrong\u003eIP 65\u003c\/strong\u003e for the electronics, the mounting position is arbitrary.\u003c\/p\u003e\n\u003cp\u003eThe device features a four-digit 7-segment display with a head that can be \u003cstrong\u003erotated by approximately 330°\u003c\/strong\u003e and a display that can be mirrored by 180°. Settings are made on the device using \u003cstrong\u003ethree buttons\u003c\/strong\u003e or via HART; the measured value can be read on-site without a host computer. The \u003cstrong\u003etwo limit contacts\u003c\/strong\u003e operate as PNP or NPN with 30 VDC and 200 mA; switching delay and failsafe can be set up to \u003cstrong\u003e999.9 s\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMeasurement is performed with a \u003cstrong\u003ePt100 in 4-wire circuit\u003c\/strong\u003e in classes A, B, and AA in the range \u003cstrong\u003e-50 … +200 °C\u003c\/strong\u003e with a smallest span of 50 K. The output is \u003cstrong\u003e4 … 20 mA with HART\u003c\/strong\u003e in the 2-wire loop; the accuracy of the measuring amplifier is \u003cstrong\u003e0.3% of the range\u003c\/strong\u003e at 16 bits. The sensor is powered from the HART current loop with \u003cstrong\u003e12 … 40 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore ordering, please note:\u003c\/strong\u003e The ambient temperature is not the medium temperature – the measuring surface can withstand up to +200 °C, but the electronics in the head only up to +80 °C, and above +85 °C they can be damaged; the sensor sits with the magnet directly on the hot surface, the source does not say how much heat reaches the head. How the adhesive force of 66 N changes with temperature is not documented; the fastening must be checked before use on hot surfaces. Galvanic isolation applies only between switching outputs and measuring amplifier, not against the loop and not against the surface on which the magnet sits. Two limit contacts are only available with M12 five- and eight-pole as well as MIL; a cable gland is not listed. The data sheet only mentions up to -50 … +250 °C on request. For configuration, the \u003cstrong\u003eHART interface with USB and software\u003c\/strong\u003e (01310-00220) is used. A CE mark, a declaration of conformity, and explosion protection are not documented in the data sheet. The identical version without display and buttons is the \u003cstrong\u003eTMMB\u003c\/strong\u003e (METS-WTM).\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eAttached instead of installed – magnetic base with 66 N from Alnico 500\u003c\/li\u003e\n\n\u003cli\u003eFour-digit display, head rotatable by approx. 330°, three buttons or HART\u003c\/li\u003e\n\n\u003cli\u003ePt100 4-wire, classes A, B, and AA, medium -50 … +200 °C\u003c\/li\u003e\n\n\u003cli\u003e4 … 20 mA with HART, accuracy 0.3% of range\u003c\/li\u003e\n\n\u003cli\u003eTwo limit contacts, switching delay up to 999.9 s\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356931858758,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TMMA_produkt_81355919-023e-421b-8b55-2077eb02789f.webp?v=1789243717"},{"product_id":"trmb-raum-widerstandsthermometer","title":"TRMB room resistance thermometer","description":"\u003cp\u003eThe \u003cstrong\u003eTRMB\u003c\/strong\u003e is a room resistance thermometer with screw terminals, manufacturer type Müller \u003cstrong\u003eRWT\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is wall-mounted and measures the air temperature in the room – in HVAC and cold storage applications. The data sheet does not mention a process connection or system pressure: The sensor measures the room air, the mounting position is arbitrary, and the protection class is \u003cstrong\u003eat least IP 66\u003c\/strong\u003e. Connection is not made via a plug, but via \u003cstrong\u003escrew terminals up to 2.5 mm²\u003c\/strong\u003e in the housing; the cable gland (\u003cstrong\u003eM12, M16 or M20x1.5\u003c\/strong\u003e) is set according to customer specifications.\u003c\/p\u003e\n\u003cp\u003eFour housings are available, allowing the design to adapt to the mounting location: three made of aluminum die-cast alloy in gray RAL 7032 – \u003cstrong\u003eAK082\u003c\/strong\u003e 80 × 125 × 57 mm, \u003cstrong\u003eAK081\u003c\/strong\u003e 75 × 80 × 57 mm, \u003cstrong\u003eAK061\u003c\/strong\u003e 64 × 58 × 36 mm – and \u003cstrong\u003e1503\u003c\/strong\u003e 120 × 80 × 58 mm made of ABS; weights range from approximately 225 to 500 g. The sensor tube is made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e or Delrin POM.\u003c\/p\u003e\n\u003cp\u003eMeasuring elements include \u003cstrong\u003e1× or 2× Pt100\u003c\/strong\u003e, \u003cstrong\u003e1× or 2× Pt1000\u003c\/strong\u003e, \u003cstrong\u003e3× Pt100\u003c\/strong\u003e or a thermocouple \u003cstrong\u003eType K\u003c\/strong\u003e, in 2-, 3- or 4-wire configuration and in classes \u003cstrong\u003eA, B and AA (B1\/3 DIN)\u003c\/strong\u003e; the range extends from \u003cstrong\u003e-50 … +100 °C\u003c\/strong\u003e. Without a transmitter, the resistance thermometer is connected directly to the terminals – the output is then the resistance or thermovoltage signal itself, and the sensor does not require a power supply. With a transmitter, \u003cstrong\u003e4 … 20 mA\u003c\/strong\u003e and \u003cstrong\u003e2 … 10 V\u003c\/strong\u003e are available, depending on the type, with 0.3% of the range or ±0.1% of the full scale value.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e Two of the four housings do not accommodate a transmitter – it is only intended for AK082 and 1503, but the combination with AK061 and AK081 is not blocked in the ordering key. The sensor tube is not dimensioned: Only material and position can be selected; length and diameter must be requested from the manufacturer. The permissible ambient temperature depends on the housing and the transmitter: Die-cast aluminum -50 … +100 °C, plastic -50 … +85 °C, with transmitter in both cases only \u003cstrong\u003e-40 … +85 °C\u003c\/strong\u003e. The transmitters are proprietary products: TP-RTD, DTW, TH-RTD, and DTW Ex only work with resistance thermometers; TP-TC only works with thermocouples. A CE mark and a declaration of conformity are not available; the marking \u003cstrong\u003eII 1G Ex ia IIC T6 … T4\u003c\/strong\u003e applies only to the DTW Ex transmitter, not to the sensor or the housing.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eFour housings: die-cast aluminum AK082, AK081, AK061 or ABS 1503\u003c\/li\u003e\n\n\u003cli\u003ePt100, Pt1000, 3× Pt100 or thermocouple Type K\u003c\/li\u003e\n\n\u003cli\u003eClasses A, B and AA (B1\/3 DIN), 2-, 3- or 4-wire, -50 to +100 °C\u003c\/li\u003e\n\n\u003cli\u003eTransmitter as an option, 4 … 20 mA or 2 … 10 V\u003c\/li\u003e\n\n\u003cli\u003eScrew terminals up to 2.5 mm², cable gland M12 to M20x1.5\u003c\/li\u003e\n\n\u003cli\u003eSensor tube made of 1.4571 or Delrin POM, protection class at least IP 66\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356931891526,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TRMB_produkt_c84c65f8-4488-4b9d-b9a7-d8bd4fcbd875.webp?v=1789243718"},{"product_id":"teme-einschraub-temperatursensor-mit-programmierbarem-messumformer","title":"TEME screw-in temperature sensor with programmable transmitter","description":"\u003cp\u003eThe \u003cstrong\u003eTEME\u003c\/strong\u003e is a compact screw-in temperature sensor with a programmable transmitter, manufacturer type Müller \u003cstrong\u003eMKTS\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt measures where temperature is taken directly in the medium: in pipelines, tanks, hydraulic and cooling circuits. The sensor tube and housing are made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, the sensor is potted and protected with \u003cstrong\u003eIP 68\u003c\/strong\u003e, and the system pressure is \u003cstrong\u003emax. 25 bar\u003c\/strong\u003e. At around \u003cstrong\u003e200 g\u003c\/strong\u003e and with a sensor tube of Ø 6 mm, it is small enough for confined installation situations, and the mounting position is arbitrary.\u003c\/p\u003e\n\u003cp\u003eBecause the sensor, output, process connection, and connector can be freely combined, a single design covers a wide variety of systems – from a bare Pt100 directly on the connector to a CANopen node according to CiA 404, from pipe threads to connectors for mobile machines and vehicles (Deutsch DT04, Super Seal, Bayonet, MIL). Instead of stocking a separate device for each signal type and each part of the system, you order the same basic form in the appropriate configuration.\u003c\/p\u003e\n\u003cp\u003eMeasurement is performed with \u003cstrong\u003eone or two Pt100 or Pt1000\u003c\/strong\u003e in the range of \u003cstrong\u003e-50 ... +200 °C\u003c\/strong\u003e with a minimum span of \u003cstrong\u003e50 K\u003c\/strong\u003e. The transmitter operates with 24-bit resolution and an accuracy of \u003cstrong\u003emax. 0.1% of the range\u003c\/strong\u003e plus sensor error; for CANopen, it is ±0.1 K with a 20 ms conversion time. Two measuring elements are only possible in the version without a transmitter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore ordering, please note:\u003c\/strong\u003e The ambient temperature is not the medium temperature – the medium can be up to +200 °C, but the electronics in the head with a transmitter can only tolerate -20 ... +80 °C, and without a transmitter -30 ... +100 °C. The 0.1% only applies between 0 and +40 °C ambient temperature. The CANopen transmitter is calibrated at the factory and cannot be configured afterwards; the analog output can be set with the \u003cstrong\u003eDEV-KMA\u003c\/strong\u003e configurator and TrComm software. The MK identifier is used three times by this manufacturer (MKTS, MKTS-GL, MKTS-SP) – please state the type designation in plain text when inquiring. The EC declaration of conformity is available, but it dates from 25.07.2011 and still refers to directives 2004\/108\/EC and 97\/23\/EC, which were replaced in 2016; the datasheet itself does not show a CE mark. Explosion protection is not documented; the intrinsically safe version is the \u003cstrong\u003eTEMG\u003c\/strong\u003e (MKTS-Ex).\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eOne design for direct resistance, 4 ... 20 mA, 0 ... 10 V and CANopen\u003c\/li\u003e\n\n\u003cli\u003eMeasuring range -50 to +200 °C, accuracy max. 0.1% of range\u003c\/li\u003e\n\n\u003cli\u003eInstallation length 50 to 1000 mm in 5 mm increments\u003c\/li\u003e\n\n\u003cli\u003eSensor tube and housing made of stainless steel 1.4571, IP 65 \/ IP 68, max. 25 bar\u003c\/li\u003e\n\n\u003cli\u003eConnectors also for mobile machines and vehicles\u003c\/li\u003e\n\n\u003cli\u003eIntrinsically safe version available as TEMG\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356931989830,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TPMA_produkt_abeb0373-f63d-4f06-8fa2-4d8d6cebe2b7.webp?v=1789243717"},{"product_id":"thma-hand-temperatursensor","title":"THMA handheld temperature sensor","description":"\u003cp\u003eThe \u003cstrong\u003eTHMA\u003c\/strong\u003e is a handheld temperature sensor with a stainless steel handle, manufacturer type Müller \u003cstrong\u003eMKTS-HA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is designed for control measurements in liquids and soft substances: The operator dips the tube into the medium and reads the value – there is no installation point and no screw connection. The handle and protective tube are made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, and the protective tube measures \u003cstrong\u003eØ 6 × 0.5 mm\u003c\/strong\u003e. The tube length is available from \u003cstrong\u003e50 to 1000 mm\u003c\/strong\u003e, with the tube end flat, pointed, or optionally heated. The weight is approximately \u003cstrong\u003e450 g\u003c\/strong\u003e, and the protection class is at least \u003cstrong\u003eIP 65 with the connection plugged in\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe same handle can be ordered with very different outputs: the \u003cstrong\u003ePt100(0) directly on the connector\u003c\/strong\u003e and thus without power supply, \u003cstrong\u003e4 … 20 mA with HART\u003c\/strong\u003e in the 2-wire loop, or digital \u003cstrong\u003eCANopen\u003c\/strong\u003e, Modbus RTG, and \u003cstrong\u003ePROFIBUS DP\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe input features a \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e in 2-, 3- or 4-wire configuration in classes \u003cstrong\u003eA, B, and B 1\/2 DIN\u003c\/strong\u003e. The resolution is \u003cstrong\u003e16 bit\u003c\/strong\u003e, the accuracy \u003cstrong\u003e0.2 K or 0.08 % of the range\u003c\/strong\u003e, the response time \u003cstrong\u003e1 s\u003c\/strong\u003e; calibration is performed via \u003cstrong\u003e2 or 6 points\u003c\/strong\u003e, set via the HART tool. The HART loop requires \u003cstrong\u003e12 … 40 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e For a handheld device, two safety-relevant specifications are missing: a permissible handle or hand temperature and a maximum immersion depth are not documented in the manufacturer's data sheet – anyone measuring at +200 °C must determine for themselves how far the tube may be immersed and whether the handle is still touchable. The ambient temperature is not the medium temperature: permissible are -40 … +85 °C ambient and -50 … +200 °C medium. The source does not state which of the two accuracy specifications – 0.2 K or 0.08 % of the range – applies. The fault message is 3.8 mA at the lower end of the usable range of 3.8 … 20.8 mA; a wire break cannot be distinguished from a measurement at the beginning of the range. The heated tip is in the order key, but not in any data line – neither power nor voltage nor control; it must be requested from the manufacturer. Not every connection carries every signal: Two sensors in 3-wire connection only work with M12 eight-pin, AMP MIL, and cable; Super Seal and Deutsch DT04 three-pin do not carry the heating. The source writes \u003cstrong\u003eModbus RTG\u003c\/strong\u003e; such a protocol does not exist, Modbus RTU is meant. The data sheet does not mention a system pressure, a protection class in the unplugged state, a CE mark, a declaration of conformity, or explosion protection.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eHandle and protective tube made of stainless steel 1.4571, Ø 6 × 0.5 mm\u003c\/li\u003e\n\n\u003cli\u003eTube length 50 to 1000 mm, tube end flat, pointed or heated\u003c\/li\u003e\n\n\u003cli\u003ePt100 or Pt1000 in 2-, 3- or 4-wire connection\u003c\/li\u003e\n\n\u003cli\u003eClasses A, B and B 1\/2 DIN, medium -50 … +200 °C\u003c\/li\u003e\n\n\u003cli\u003eResistance directly, 4 … 20 mA with HART or digital\u003c\/li\u003e\n\n\u003cli\u003eAccuracy 0.2 K or 0.08 % of the range, response time 1 s\u003c\/li\u003e\n\n\u003cli\u003eIP 65 with plugged-in connection, weight approximately 450 g\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356932251974,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/THMA_produkt_2cf31cdd-001a-4836-8380-d673d5417192.webp?v=1789243685"},{"product_id":"trmc-raum-klima-sensor","title":"TRMC room climate sensor","description":"\u003cp\u003eThe \u003cstrong\u003eTRMC\u003c\/strong\u003e is a room climate sensor for temperature and relative humidity, manufacturer type Müller \u003cstrong\u003eRKS\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is wall-mounted, combines two measured variables in an aluminum housing and displays them on site – designed for refrigeration systems on ships, for cold rooms and for building services. The housing is an \u003cstrong\u003ealuCase AC092 with 160 × 90 × 60 mm\u003c\/strong\u003e made of die-cast aluminum, weighing a maximum of \u003cstrong\u003e1.1 kg\u003c\/strong\u003e; connection is via \u003cstrong\u003escrew terminals up to 2.5 mm²\u003c\/strong\u003e and three cable glands \u003cstrong\u003eM16x1.5\u003c\/strong\u003e. The protection class is \u003cstrong\u003eIP 65\u003c\/strong\u003e without and \u003cstrong\u003eIP 63\u003c\/strong\u003e with humidity sensor, which sits behind a PTFE filter.\u003c\/p\u003e\n\u003cp\u003eWhere otherwise two devices would be wall-mounted, here there is one: transmitter and display are not accessories, but part of the order key. The display is \u003cstrong\u003e4-digit and 7-segment\u003c\/strong\u003e, 8 mm high, its range of \u003cstrong\u003e-999 … 9999\u003c\/strong\u003e digits is programmable.\u003c\/p\u003e\n\u003cp\u003eTemperature is measured by \u003cstrong\u003e1× or 2× Pt100\u003c\/strong\u003e in 2-, 3- or 4-wire circuits in classes \u003cstrong\u003eB, A, B 1\/2 DIN and B 1\/3 DIN\u003c\/strong\u003e, the protective tube is made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e; the humidity sensor measures \u003cstrong\u003e0 … 100 % RH\u003c\/strong\u003e with \u003cstrong\u003e±2 % RH\u003c\/strong\u003e from 5 … 95 % RH at 10 … 40 °C. The two measured variables take separate paths: Humidity is output directly as \u003cstrong\u003e4 … 20 mA\u003c\/strong\u003e, \u003cstrong\u003e0 … 10 V\u003c\/strong\u003e or \u003cstrong\u003e2 … 10 V\u003c\/strong\u003e, for temperature a transmitter \u003cstrong\u003eTAP2L or TMRO\u003c\/strong\u003e can be selected. The device is powered by \u003cstrong\u003e24 … 30 VDC\u003c\/strong\u003e; limit contacts are not mentioned in the data sheet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e With the humidity sensor, the protection class decreases from IP 65 to IP 63 – the PTFE filter must allow air to pass through, so the version with humidity is no longer protected against jet water. The humidity sensor requires air movement: at least 1 m\/s across the sensor at the current output and 0.5 m\/s at the voltage output; measurement in still air is not guaranteed. The source contradicts itself regarding the measuring range: feature list \u003cstrong\u003e-40 … +80 °C\u003c\/strong\u003e, data table of the temperature sensor -50 … +100 °C – the smaller value is the safe one; the display only operates from 0 to +80 °C. The power supply is also stated differently twice in the sheet: feature list 24 VDC, order key 24 … 30 VDC – we use the value of the key. The protective tube is designated 1.4571, but not dimensioned; length and diameter must be requested. Long-term drift and calibration interval of the humidity sensor are not documented, nor are a CE mark and explosion protection.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eTemperature and relative humidity in one device\u003c\/li\u003e\n\n\u003cli\u003eHumidity 0 … 100 % RH, ±2 % RH from 5 to 95 % RH\u003c\/li\u003e\n\n\u003cli\u003e1× or 2× Pt100, classes B to B 1\/3 DIN, measuring range -40 to +80 °C\u003c\/li\u003e\n\n\u003cli\u003eSeparate outputs, humidity as 4 … 20 mA, 0 … 10 V or 2 … 10 V\u003c\/li\u003e\n\n\u003cli\u003eDisplay 7-segment, 4-digit, 8 mm, -999 to 9999 digits\u003c\/li\u003e\n\n\u003cli\u003eAluminum housing 160 × 90 × 60 mm, maximum 1.1 kg, IP 65 – with humidity sensor IP 63\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356932383046,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TRMC_produkt_b8424803-bcdb-4ec4-b028-a9bbf5af8f91.webp?v=1789243718"},{"product_id":"tnma-einstech-thermometer-hart","title":"TNMA insertion thermometer, HART","description":"\u003cp\u003eThe \u003cstrong\u003eTNMA\u003c\/strong\u003e is an immersion thermometer in the form of a handheld lance with HART, manufacturer type Müller \u003cstrong\u003eMKTS-EL\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is designed for mobile use – hay, compost, hot asphalt: The lance is inserted into the material until the tip is deep enough. It is available in lengths from \u003cstrong\u003e500 to 2000 mm\u003c\/strong\u003e and upon request, with \u003cstrong\u003eØ 10 mm\u003c\/strong\u003e made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e. The weight is approximately \u003cstrong\u003e845 g\u003c\/strong\u003e (1000 mm with display), the protection class is \u003cstrong\u003eIP 65 for the electronics and IP 68 for the sensor\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe process connection is explicitly listed in the data sheet as a \u003cstrong\u003ehandheld lance, no installation\u003c\/strong\u003e: There are no threads or sealing surfaces. Readings are taken directly from the handle – the \u003cstrong\u003e7-segment LCD\u003c\/strong\u003e has a resolution of \u003cstrong\u003e0.1 °C\u003c\/strong\u003e, its accuracy is ±1% or 1°C, whichever is greater, and it runs on a \u003cstrong\u003eCR 2032 battery\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAt the input, there is a \u003cstrong\u003ePt100 in 3-wire circuit\u003c\/strong\u003e in classes A, B, and AA, or alternatively a \u003cstrong\u003eType K thermocouple\u003c\/strong\u003e. The maximum range extends from \u003cstrong\u003e-50 ... +400 °C\u003c\/strong\u003e with a smallest span of 50 K. The output is either the \u003cstrong\u003eresistance directly on the connector\u003c\/strong\u003e or \u003cstrong\u003e4 ... 20 mA with HART\u003c\/strong\u003e in the 2-wire loop; the total accuracy via HART is \u003cstrong\u003e0.3% of the range\u003c\/strong\u003e at 16 bit. The transmitter is supplied from the current loop with \u003cstrong\u003e10 ... 35 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The sensor ranges up to +400 °C, but the factory setting of the transmitter only goes up to +200 °C; if you want to measure higher, you must specify the configuration as custom. The ambient temperature is not the medium temperature: With the transmitter, -20 ... +80 °C is permissible, without the transmitter -30 ... +100 °C, the medium may have -50 ... +400 °C. Supply and burden formula do not match: 10 ... 35 VDC are specified, but the burden formula calculates with UB - 12 V and results in a negative value below 12 V; sister sheets consistently state 12 ... 40 VDC. The source provides no information on the lifespan of the CR 2032 battery or battery regulations. A statement \"system pressure 25 bar\" is on the sheet, but has no discernible meaning for a handheld lance without a process connection – suitability for process pressure is therefore not proven. Super Seal and Deutsch DT04 three-pole only lead one sensor. Configuration is done using the \u003cstrong\u003eHART interface with USB and software\u003c\/strong\u003e (01310-00220). A CE mark, a declaration of conformity, and explosion protection are not documented in the data sheet.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a Glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eHandheld lance Ø 10 mm in 500 to 2000 mm length – no installation required\u003c\/li\u003e\n\n\u003cli\u003ePt100 in 3-wire circuit or Type K thermocouple\u003c\/li\u003e\n\n\u003cli\u003eMedium -50 ... +400 °C, accuracy 0.3% of range at 16 bit\u003c\/li\u003e\n\n\u003cli\u003e4 ... 20 mA with HART or resistance directly on the connector\u003c\/li\u003e\n\n\u003cli\u003eDisplay on handle with 0.1 °C resolution, CR 2032 battery\u003c\/li\u003e\n\n\u003cli\u003eLance made of stainless steel 1.4571, IP 65 \/ IP 68\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356932514118,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TNMA_produkt_7ddcdd9d-ce9b-4939-8553-8159af3458b3.webp?v=1789243717"},{"product_id":"temg-eigensicherer-kompakt-temperatursensor","title":"TEMG intrinsically safe compact temperature sensor","description":"\u003cp\u003eThe \u003cstrong\u003eTEMG\u003c\/strong\u003e is an intrinsically safe compact temperature sensor for hazardous areas, manufacturer type Müller \u003cstrong\u003eMKTS-Ex\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIt covers measuring points in gas-hazardous areas – tanks, separators, pipelines with flammable media – without explosion-proof encapsulation or separating component in the field. The sensor tube, housing body and plug insert are made entirely of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, the system pressure is \u003cstrong\u003emax. 25 bar\u003c\/strong\u003e, and the protection class is \u003cstrong\u003eIP 65 \/ IP 68\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIt is the intrinsically safe version of the same design platform: same housing, same outputs, plus \u003cstrong\u003eATEX\u003c\/strong\u003e and \u003cstrong\u003eIECEx\u003c\/strong\u003e for Zone 0.\u003c\/p\u003e\u003cp\u003eMeasurement is performed with \u003cstrong\u003eone or two Pt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, only in \u003cstrong\u003eClass A\u003c\/strong\u003e, at \u003cstrong\u003emax. 0.1 % of the range\u003c\/strong\u003e. The measurement range of the data table extends from \u003cstrong\u003e-50 … +200 °C\u003c\/strong\u003e, the smallest span is \u003cstrong\u003e50 K\u003c\/strong\u003e; the medium temperature additionally limits the temperature class: \u003cstrong\u003e+425 °C in T1\u003c\/strong\u003e, +275 °C in T2, +180 °C in T3, +115 °C in T4, +80 °C in T5 and \u003cstrong\u003e+65 °C in T6\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBefore ordering, please note:\u003c\/strong\u003e The marking is \u003cstrong\u003eII 1 G Ex ia IIC T6..T1 Ga\u003c\/strong\u003e, plus II 1\/2 G Ga\/Gb and II 2 G Gb; Zone 0, 1 and 2 are approved for gases. The intrinsically safe maximum values at both outputs are \u003cstrong\u003eUi 30 VDC, Ii 110 mA, Pi 1 W\u003c\/strong\u003e, passive 30 V, 100 mA and 100 mW, with \u003cstrong\u003eCi 66 nF\u003c\/strong\u003e and \u003cstrong\u003eLi 330 µH\u003c\/strong\u003e (330 m cable). Both certificate numbers end with X – \u003cstrong\u003eTÜV 21 ATEX 201293 X\u003c\/strong\u003e and \u003cstrong\u003eIECEx TUN 21.0005X\u003c\/strong\u003e – and include special conditions; the source mentions heat backflow, impact and friction, and electrostatic charging. The permissible ambient temperature depends on the temperature class and the output type: current output -40 … +75 °C, voltage output only -40 … +50 °C, passive -50 … +100 °C; in T5 and T6, the source calculates the limit from the power dissipation, the corresponding table should be read before design. Measurement range and medium temperature contradict each other in the data sheet: feature bar -50 … +200 °C, data table -50 … +425 °C, plus the limit per temperature class – the smallest of the three values applies. Two measuring elements are only available without a transmitter; the installation length (10 … 300 mm) must be specified. The product identification GN also appears verbatim on the MKTS-GLEx sheet; please specify the type designation in plain text. Configuration is done with the \u003cstrong\u003eDEV-KMA\u003c\/strong\u003e and TrComm. The data sheet mentions \u003cstrong\u003e2014\/34\/EU\u003c\/strong\u003e as a guideline; a CE mark is not documented there. The certificates are available on request and for download according to the source, we do not have them. The version with additional marine approval is the \u003cstrong\u003eTEMF\u003c\/strong\u003e (MKTS-GLEx).\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eMarking II 1 G Ex ia IIC T6..T1 Ga, Zone 0, 1 and 2 for gases\u003c\/li\u003e\n\n\u003cli\u003eATEX TÜV 21 ATEX 201293 X and IECEx TUN 21.0005X, both with X\u003c\/li\u003e\n\n\u003cli\u003ePt100 or Pt1000 in Class A, max. 0.1 % of the range\u003c\/li\u003e\n\n\u003cli\u003eMedium temperature up to +425 °C in T1, +65 °C in T6\u003c\/li\u003e\n\n\u003cli\u003eUi 30 VDC, Ii 110 mA, Pi 1 W, Ci 66 nF, Li 330 µH\u003c\/li\u003e\n\n\u003cli\u003e4 … 20 mA, 0…10 V or resistance directly at the connector\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356932546886,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TPMC_produkt_f044c3e0-b2af-4bde-9c66-ccac6c918a85.webp?v=1789243717"},{"product_id":"tsmb-anlegesensor-gefedert-io-link","title":"TSMB spring-loaded surface sensor with IO-Link","description":"\u003cp\u003eThe \u003cstrong\u003eTSMB\u003c\/strong\u003e is a contact sensor with a spring-loaded measuring tip and an IO-Link interface, manufacturer type Müller \u003cstrong\u003eMKTS-SPIO\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIt measures on the surface and in bearings: The compression spring holds the measuring tip with a \u003cstrong\u003e14 mm travel (±1 mm)\u003c\/strong\u003e at the measuring point, even if the component moves or expands due to heat – a rigidly screwed-in sensor would lose contact in such a situation. The sensor tube measures \u003cstrong\u003eØ 6 mm\u003c\/strong\u003e made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, the compression spring is made of spring steel \u003cstrong\u003e1.4310\u003c\/strong\u003e, the protection class is \u003cstrong\u003eIP 65 \/ IP 68\u003c\/strong\u003e, the installation length is \u003cstrong\u003e45 or 65 mm\u003c\/strong\u003e, the weight is approximately \u003cstrong\u003e200 g\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eThe mechanics are the same as with the \u003cstrong\u003eTSMA\u003c\/strong\u003e (MKTS-SP); instead of a HART transmitter, an IO-Link transmitter is installed here. The measured value is sent digitally to the \u003cstrong\u003eIO-Link\u003c\/strong\u003e master, and the sensor is also parameterized there – a configuration device is not necessary, the description of the values is in the device file \u003cstrong\u003eIODD MKTS-SPIO\u003c\/strong\u003e. The electrical connection is \u003cstrong\u003eM12x1 four-pin\u003c\/strong\u003e as the only option; the sensor does not have a display or limit contacts.\u003c\/p\u003e\u003cp\u003eThe input has \u003cstrong\u003ea Pt100\u003c\/strong\u003e in a \u003cstrong\u003e3-wire circuit\u003c\/strong\u003e or a thermocouple \u003cstrong\u003eType J, K or N\u003c\/strong\u003e. The nominal range extends from \u003cstrong\u003e-50 … +150 °C\u003c\/strong\u003e in all versions; a measuring range of \u003cstrong\u003e0 … 100 °C\u003c\/strong\u003e is set ex works, customizable. The source states the accuracy as \u003cstrong\u003emax. 0.02 % of the range\u003c\/strong\u003e plus sensor error at \u003cstrong\u003e16 Bit\u003c\/strong\u003e and \u003cstrong\u003e20 ms\u003c\/strong\u003e response time, powered by \u003cstrong\u003e24 VDC\u003c\/strong\u003e with reverse polarity protection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e This sensor does not withstand process pressure. The source explicitly states: System pressure not possible, the process connection has no sealing effect; the Pressure Equipment Directive is therefore not applicable. The ambient temperature is not the medium temperature: The electronics in the head tolerate \u003cstrong\u003e-20 … +80 °C\u003c\/strong\u003e, the medium up to +150 °C; the source does not state what neck length or insulation is required for this. The accuracy specification is remarkably favorable: 0.02 % of the range at 16 Bit, while the sister sheets with 24 Bit only guarantee 0.1 % and the MKTS-SP with the same design states 0.3 % – before designing, the value must be confirmed with the manufacturer, the sensor error is always added. The relationship between filter and response time is also striking: 25 s filter at 20 ms response time. The datasheet does not specify a minimum span. A CE mark is not documented, a declaration of conformity is not available; explosion protection is also not documented.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eSpring-loaded measuring tip, travel 14 mm ±1 mm\u003c\/li\u003e\n\n\u003cli\u003eIO-Link with signal level 0\/24 V, parameterization via the master\u003c\/li\u003e\n\n\u003cli\u003eRange -50 to +150 °C, factory setting 0 … 100 °C\u003c\/li\u003e\n\n\u003cli\u003eInstallation length 45 or 65 mm, sensor tube Ø 6 mm made of 1.4571\u003c\/li\u003e\n\n\u003cli\u003eVersion with HART available as TSMA\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356932645190,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TSMB_produkt_1b00777b-4c87-4666-b6a6-cf34fa5127d4.webp?v=1789243718"},{"product_id":"txma-schienen-temperatursensor","title":"TXMA rail temperature sensor","description":"\u003cp\u003eThe \u003cstrong\u003eTXMA\u003c\/strong\u003e is a rail temperature sensor for railway applications, manufacturer type Müller \u003cstrong\u003eSTSBA\u003c\/strong\u003e. It measures the temperature of the running rail and provides the measured value that controls the \u003cstrong\u003epoint heating system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe housing fits rail profiles \u003cstrong\u003eS 49, S 54, UIC 60, and R 65\u003c\/strong\u003e without modification. It is fastened with a \u003cstrong\u003eclamp and counter-clamp\u003c\/strong\u003e using an \u003cstrong\u003eM10\u003c\/strong\u003e threaded rod of strength class 10.9, tightening torque \u003cstrong\u003e68 Nm\u003c\/strong\u003e; installation must be \u003cstrong\u003ebelow the heating element\u003c\/strong\u003e, otherwise, the sensor will measure the heating system instead of the rail. The housing measures \u003cstrong\u003e68 × 64 mm\u003c\/strong\u003e, is fully potted, made of material \u003cstrong\u003ex 25 CrNiSi 18.9\u003c\/strong\u003e and weighs approximately \u003cstrong\u003e1.5 kg\u003c\/strong\u003e; the operating temperature ranges from \u003cstrong\u003e-40 … +85 °C\u003c\/strong\u003e, optionally -50 … +105 °C.\u003c\/p\u003e\n\u003cp\u003eThere is no plug: The connection cable \u003cstrong\u003eH07BQ-F, 2 × 1.5 mm²\u003c\/strong\u003e is led out of the potting via a \u003cstrong\u003ePG 11\u003c\/strong\u003e screw connection. The output is \u003cstrong\u003egalvanically isolated\u003c\/strong\u003e, the insulation voltage is \u003cstrong\u003e1500 VAC for 60 s\u003c\/strong\u003e – in the track, where traction currents and return current flow, this is the decisive value.\u003c\/p\u003e\n\u003cp\u003eA \u003cstrong\u003ePt100 in 4-wire Class A configuration\u003c\/strong\u003e is installed in the housing as the measuring element. The measuring range is configurable and set ex works to \u003cstrong\u003e-30 … +60 °C\u003c\/strong\u003e, the resolution is \u003cstrong\u003e0.1 °C\u003c\/strong\u003e, and the measurement deviation is less than \u003cstrong\u003e±0.05 % of the measuring span\u003c\/strong\u003e. The output is \u003cstrong\u003e4 … 20 mA\u003c\/strong\u003e in 2-wire technology, \u003cstrong\u003ereversible to 20 … 4 mA\u003c\/strong\u003e, with output limits \u003cstrong\u003e3.8 … 20.5 mA according to NAMUR\u003c\/strong\u003e. The sensor is powered with \u003cstrong\u003e9 … 36 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e A railway standard is not documented – the sheet refers to a \"Technical Approval from Deutsche Bahn AG\" but does not provide a number or date, and EN 50121, EN 50155, and EN 45545 are not mentioned; proof of compliance must be requested from the manufacturer before use in railway applications. The 1500 VAC for 60 s is insulation voltage, not continuous operating insulation; an overvoltage category and lightning protection are not specified. The data sheet does not state a degree of protection – the housing is fully potted, an IP code is missing. To change the measuring range, the \u003cstrong\u003econfiguration set with DTM-Control software\u003c\/strong\u003e is required, connection via \u003cstrong\u003eRS 232-C\u003c\/strong\u003e; if configured during operation, the connection to the point heating control is interrupted, and whether the set is still available must be clarified with the manufacturer. A CE mark and explosion protection are not documented.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a Glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eFits S 49, S 54, UIC 60, and R 65 without modification\u003c\/li\u003e\n\n\u003cli\u003ePt100 4-wire Class A, resolution 0.1 °C\u003c\/li\u003e\n\n\u003cli\u003e4 … 20 mA, reversible to 20 … 4 mA, limits 3.8 … 20.5 mA according to NAMUR\u003c\/li\u003e\n\n\u003cli\u003eGalvanically isolated, insulation voltage 1500 VAC for 60 s\u003c\/li\u003e\n\n\u003cli\u003eHousing 68 × 64 mm stainless steel, fully potted, approx. 1.5 kg\u003c\/li\u003e\n\n\u003cli\u003eClamp with M10 threaded rod, tightening torque 68 Nm\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356932677958,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TXMA_produkt_5edabb5d-a1eb-43c9-8956-cdd96af24a10.webp?v=1789243719"},{"product_id":"temh-kompakt-temperatursensor-mit-io-link","title":"TEMH compact temperature sensor with IO-Link","description":"\u003cp\u003eThe \u003cstrong\u003eTEMH\u003c\/strong\u003e is a compact temperature sensor with an IO-Link interface, manufacturer type Müller \u003cstrong\u003eMKTS-IO\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIt measures where the temperature is taken directly in the medium – in pipelines, tanks, hydraulic and cooling circuits. The sensor tube Ø 6 mm and housing are made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, the electronics are potted (\u003cstrong\u003eIP 65 \/ IP 68\u003c\/strong\u003e), and the system pressure is \u003cstrong\u003emax. 25 bar\u003c\/strong\u003e. The insertion length ranges from 50 to 1000 mm, and the mounting position is arbitrary.\u003c\/p\u003e\u003cp\u003eThe benefit lies in its digital integration: the measured value is sent via \u003cstrong\u003eIO-Link\u003c\/strong\u003e to the master, where the sensor is also parameterized – without a configuration device and without analog wiring; the settable values are described in the device file \u003cstrong\u003eIODD MKTS\u003c\/strong\u003e. As the only one in the series, it also accommodates \u003cstrong\u003etype J, K, and N thermocouples\u003c\/strong\u003e, thereby covering measurement points with existing thermocouple wiring. Electrically, there is exactly one connection, \u003cstrong\u003eM12x1 four-pin\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eThe input contains \u003cstrong\u003ea Pt100\u003c\/strong\u003e in a \u003cstrong\u003e3-wire circuit\u003c\/strong\u003e in classes A, B, and AA, class C on request, or alternatively a thermocouple. The nominal range for all elements is from \u003cstrong\u003e-50 … +200 °C\u003c\/strong\u003e. The source states the accuracy as \u003cstrong\u003emax. 0.02 % of the range\u003c\/strong\u003e plus sensor error at \u003cstrong\u003e16 bit\u003c\/strong\u003e and \u003cstrong\u003e20 ms\u003c\/strong\u003e response time; the sensor is powered with \u003cstrong\u003e24 VDC\u003c\/strong\u003e with reverse polarity protection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The ambient temperature is not the medium temperature – the medium may be up to +200 °C, but the electronics in the head only tolerate -20 … +80 °C; the source does not state what neck length or insulation is required for this. The accuracy specification contradicts the sister sheets: here, 0.02 % of the range is stated for 16-bit resolution, while the 24-bit versions only guarantee 0.1 % – the better value is on the coarser converter, which needs to be confirmed with the manufacturer before design. Filters and response time also do not match: 25 s filter at 20 ms response time, without explanation in the source. The product identification is not unambiguously documented: the order key has a placeholder in the second position, the product overview lists MX – please specify the type designation in plain text. A CE mark is not documented, and a declaration of conformity is not available; regarding the IO-Link interface, the source names the specification but no version number or test certificate. Explosion protection is not documented.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eIO-Link interface with signal level 0\/24 V, parameterization via the master\u003c\/li\u003e\n\n\u003cli\u003eAs the only one in the series, also type J, K, and N thermocouples\u003c\/li\u003e\n\n\u003cli\u003ePt100 3-wire in classes A, B, and AA\u003c\/li\u003e\n\n\u003cli\u003eNominal range -50 to +200 °C for each element\u003c\/li\u003e\n\n\u003cli\u003eA single M12x1 four-pin connection, no variety of connectors\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356933890374,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TPME_produkt_41cde47e-8c9e-4325-98c9-99709e30d2df.webp?v=1789243718"},{"product_id":"tpmf-standard-temperatursensor","title":"TPMF standard temperature sensor","description":"\u003cp\u003eThe \u003cstrong\u003eTPMF\u003c\/strong\u003e is a standard temperature sensor without electronics, manufacturer type Müller \u003cstrong\u003eSTS\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIt measures directly in the medium and is installed using a \u003cstrong\u003ecompression fitting G1\/4\" or G1\/2\"\u003c\/strong\u003e. The material throughout is stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, the sensor tube measures \u003cstrong\u003eØ 6 × 0.5 mm\u003c\/strong\u003e, the total length is \u003cstrong\u003e163 mm\u003c\/strong\u003e, of which 140 mm is tube, the housing body is completely potted internally, protection class \u003cstrong\u003eIP 67\u003c\/strong\u003e when connected, installation position is arbitrary. At \u003cstrong\u003eapprox. 23 g\u003c\/strong\u003e, it is the lightest in the series and hardly strains the measuring point.\u003c\/p\u003e\u003cp\u003eIt is the basic type of the series and solves a procurement problem, not a metrological one: It has \u003cstrong\u003eno order key, but a single order number 100-02161\u003c\/strong\u003e. Where otherwise ten digits would have to be set correctly – transmitter, number of wires, class, installation length, process connection, connector insert, configuration – there is only one version here.\u003c\/p\u003e\u003cp\u003eThe measuring element is \u003cstrong\u003ea Pt100\u003c\/strong\u003e in a \u003cstrong\u003e4-wire circuit\u003c\/strong\u003e of \u003cstrong\u003eClass A\u003c\/strong\u003e, the measuring range of the medium extends from \u003cstrong\u003e-20 … +150 °C\u003c\/strong\u003e. The sensor is a \u003cstrong\u003epassive measuring element\u003c\/strong\u003e and provides a resistance: The four wires are directly connected to the four pins of the \u003cstrong\u003eM12x1, four-pole, A-coded\u003c\/strong\u003e connector, a transmitter is not present. This means there is nothing to power and nothing to configure.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e The ambient temperature is not the medium temperature – the medium may be up to +150 °C warm, the head tolerates only -20 … +80 °C, storage -20 … +85 °C; the source does not state what neck length or insulation is required for this, condensation is harmless. The system pressure of \u003cstrong\u003emax. 10 bar\u003c\/strong\u003e is the smallest in this series – the other MKTS versions support 25 bar; the data sheet does not state the reason, but the compression fitting is a plausible explanation. The compression fitting is not included in the scope of delivery and has its own order numbers: G1\/4\" is \u003cstrong\u003e047-00067\u003c\/strong\u003e, G1\/2\" is \u003cstrong\u003e047-00066\u003c\/strong\u003e, steel clamping ring, material stainless steel 1.4571, for Ø 6 mm; the corresponding socket and the six connection cables from the source are also not included. This version does not offer other elements, other classes, or a different number of wires. The source does not specify a standard for Class A. A CE mark is not documented, a declaration of conformity is not available; explosion protection is also not documented.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eA single order number 100-02161, no order key\u003c\/li\u003e\n\n\u003cli\u003ePt100 Class A in 4-wire circuit, passive without power supply\u003c\/li\u003e\n\n\u003cli\u003eMedium -20 to +150 °C, ambient -20 to +80 °C\u003c\/li\u003e\n\n\u003cli\u003eOnly approx. 23 g, total length 163 mm, 140 mm tube\u003c\/li\u003e\n\n\u003cli\u003eM12x1 four-pole A-coded, resistance directly on the pins\u003c\/li\u003e\n\n\u003cli\u003eThroughout stainless steel 1.4571, protection class IP 67, max. 10 bar\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356934218054,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TPMF_produkt_3cb47d57-a333-4cf7-af3a-3cf9dec36179.webp?v=1789243718"},{"product_id":"tpmg-kompakt-temperatursensor-in-hygienischer-ausfuehrung-mit-hart","title":"TPMG hygienic compact temperature sensor with HART","description":"\u003cp\u003eThe \u003cstrong\u003eTPMG\u003c\/strong\u003e is a compact temperature sensor in a hygienic design with HART, manufacturer type Müller \u003cstrong\u003eMHY-TS\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIt is the hygienic version of the same design platform: The process connection is \u003cstrong\u003eG1\/2\" in a hygienic design\u003c\/strong\u003e or an immersion probe, sensor tube, process connection and housing are continuously made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, the connector insert is always metal – plastic is not provided. It is designed for measuring points that are cleaned and where no plastic should be in contact with the medium. The system pressure is \u003cstrong\u003emax. 25 bar\u003c\/strong\u003e, the protection class \u003cstrong\u003eIP 65 \/ IP 68\u003c\/strong\u003e, the installation length 50 to 1000 mm.\u003c\/p\u003e\u003cp\u003eOne design covers several signal types: \u003cstrong\u003e4 … 20 mA with HART\u003c\/strong\u003e in the 2-wire loop, \u003cstrong\u003eCANopen\u003c\/strong\u003e according to CiA 404, or the version without a transmitter with connections directly on the plug. The HART transmitter is set with the \u003cstrong\u003eHART interface with USB and software\u003c\/strong\u003e, order number \u003cstrong\u003e01310-00220\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eThe input has \u003cstrong\u003eone or two Pt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e in classes A, B, and AA. The measuring range extends from \u003cstrong\u003e-50 … +200 °C\u003c\/strong\u003e, the smallest span is \u003cstrong\u003e50 K\u003c\/strong\u003e. The total accuracy via HART is \u003cstrong\u003e0.3% of the range\u003c\/strong\u003e at \u003cstrong\u003e16 bit\u003c\/strong\u003e resolution and 10 measurements per second, via CANopen at \u003cstrong\u003e±0.1 K\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The datasheet does not mention a hygiene approval. The sheet describes the sensor as hygienic but does not document EHEDG or 3-A, no surface roughness Ra, no information on cleanability, no sealing materials, and no FDA conformity; only material 1.4571 and the G1\/2\" hygienic process connection are confirmed – those who need approval must request it from the manufacturer. The ambient temperature is not the medium temperature: The medium can be up to +200 °C, the electronics in the head tolerate only -20 … +80 °C with a transmitter, and -30 … +100 °C without a transmitter. For CANopen, only the eight-pin connector is suitable because the CAN bus pinout requires five pins – shield, plus, ground, CAN High, and CAN Low. The CANopen transmitter is calibrated at the factory; only the HART transmitter can be adjusted later. When communicating via a HART modem, a resistance of \u003cstrong\u003e250 Ω\u003c\/strong\u003e must be considered. The sheet does not mention a CE mark, a directive, or a declaration of conformity; explosion protection is also not documented.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eProcess connection G1\/2\" hygienic or immersion probe\u003c\/li\u003e\n\n\u003cli\u003eSensor tube, connection and housing continuously made of stainless steel 1.4571\u003c\/li\u003e\n\n\u003cli\u003eConnector insert always metal, no plastic on the device\u003c\/li\u003e\n\n\u003cli\u003e4 … 20 mA with HART or CANopen according to CiA 404\u003c\/li\u003e\n\n\u003cli\u003eTotal accuracy 0.3% of the range at 16 bit, measuring range -50 to +200 °C\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356934775110,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TPMG_produkt_4fda4d2f-f426-4e8b-8bdc-5938eddb5541.webp?v=1789243718"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/collections\/LPMB-1.jpg?v=1788195707","url":"https:\/\/octogon.org\/en\/collections\/temperature-sensors.oembed?page=2","provider":"octogon GmbH","version":"1.0","type":"link"}