{"title":"Measurement Electronics SIL \/ PL","description":"\u003ch2\u003eMeasuring electronics for functional safety — SIL and Performance Level\u003c\/h2\u003e\n\u003cp\u003eWhen a force or load measurement takes on a protective function — overload shutdown on a press, load limiting on a hoist, presence monitoring in a plant — an ordinary measuring amplifier is not enough. The measuring chain has to be testable, and in the event of a fault it has to move into the safe state by itself.\u003c\/p\u003e\n\u003cp\u003eHere you will find both routes to that:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/en\/collections\/messelektronik-sil3-ple\"\u003eSIL3 \/ PL e with a safety controller.\u003c\/a\u003e\u003c\/strong\u003e The amplifier puts one bridge signal onto two galvanically isolated outputs, a \u003ca href=\"\/en\/products\/esmd-scu-dr\"\u003eprogrammable safety controller\u003c\/a\u003e compares them and shuts down if they diverge. Redundancy across two channels — the highest level available here.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/en\/collections\/messelektronik-sil1-plc\"\u003eSIL1 \/ PL c with a built-in protective function.\u003c\/a\u003e\u003c\/strong\u003e A second amplifier, two comparators and a solid-state relay sit inside the device and monitor the bridge independently of the measuring channel. No safety controller is needed for this, and the device remains a usable measuring amplifier with 0.1 % of the measuring range at the same time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHousing by installation location\u003c\/h3\u003e\n\u003cp\u003eFor the control cabinet the DR22.5 DIN rail version with IP20, for mounting on the machine the U-CASE 2 field housing with IP65. The series covers both safety levels in both designs.\u003c\/p\u003e\n\u003ch3\u003eWhat goes with it\u003c\/h3\u003e\n\u003cp\u003eYou will find the matching sensors under \u003ca href=\"\/en\/collections\/waegezellen-kraftaufnehmer\"\u003eload cells \u0026amp; force transducers\u003c\/a\u003e, the rest of the evaluation electronics under \u003ca href=\"\/en\/collections\/messelektronik\"\u003emeasuring electronics\u003c\/a\u003e. The basics of SIL and Performance Level, the safety architecture with two independent strain gauge bridges and the figures for plant certification – MTTFd, B10d, DC, FMEA – are explained on the page \u003ca href=\"\/en\/pages\/funktionale-sicherheit-sil-pl\"\u003eFunctional Safety SIL | PL\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"esma-dms-bruecken-messverstaerker-sil3","title":"ESMA strain gauge bridge amplifier, SIL3","description":"\u003cp\u003e\u003cstrong\u003eStrain gauge bridge amplifier SMM-DR\u003c\/strong\u003e for safety-related force and load measurement rated \u003cstrong\u003eSIL3\u003c\/strong\u003e and \u003cstrong\u003ePL e category 3\u003c\/strong\u003e. The amplifier puts \u003cstrong\u003eone\u003c\/strong\u003e bridge signal on \u003cstrong\u003etwo galvanically isolated current outputs\u003c\/strong\u003e, so that a safety controller can check the two channels against each other.\u003c\/p\u003e\n\u003cp\u003eThis is a safety component, not a measuring instrument: the redundancy comes from the two outputs, not from higher measuring accuracy. If the channels deviate by more than 10 %, the controller takes the plant to its safe state.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003etest pulse input\u003c\/strong\u003e allows the measuring chain to be checked during operation: a 24 VDC pulse raises the current of channel B by 1 mA. The matching safety controller is the SCU-DR from the same range.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures of the SMM-DR\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e✅Sensor input: \u003cstrong\u003e1 × strain gauge full bridge 350 Ω\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Bridge sensitivity: up to \u003cstrong\u003e4 mV\/V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Bridge supply: 5 VDC\u003c\/p\u003e\n\u003cp\u003e✅Analog output: \u003cstrong\u003e2 × 4 … 20 mA\u003c\/strong\u003e, channel A and B, galvanically isolated\u003c\/p\u003e\n\u003cp\u003e✅Nominal range: 8 … 16 mA within 4 … 20 mA\u003c\/p\u003e\n\u003cp\u003e✅Load resistance: 500 Ω max.\u003c\/p\u003e\n\u003cp\u003e✅Test pulse input: 24 VDC ±20 %, ≤ 250 Hz\u003c\/p\u003e\n\u003cp\u003e✅Safety rating: \u003cstrong\u003eSIL3\u003c\/strong\u003e (EN 61508, EN 62061) · \u003cstrong\u003ePL e category 3\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Supply: 24 VDC ±10 %, 100 mA max.\u003c\/p\u003e\n\u003cp\u003e✅Housing: DR22.5 for TS 35 rail · 117.2 × 22.5 × 113.6 mm\u003c\/p\u003e\n\u003cp\u003e✅Protection: IP20\u003c\/p\u003e\n\u003cp\u003e✅Temperature coefficient: \u0026lt; 50 ppm\/K\u003c\/p\u003e\n\u003cp\u003e✅Order number: 0600-00492\u003c\/p\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57265729929542,"sku":null,"price":860.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/ESMA_SMM-DR__product.png?v=1788560250"},{"product_id":"esmb-dms-bruecken-messverstaerker-sil3-ip65","title":"ESMB strain gauge bridge amplifier, SIL3, IP65","description":"\u003cp\u003e\u003cstrong\u003eStrain gauge bridge amplifier SMM-HD\u003c\/strong\u003e for safety-related force and load measurement rated \u003cstrong\u003eSIL3\u003c\/strong\u003e and \u003cstrong\u003ePL e category 3\u003c\/strong\u003e — in an \u003cstrong\u003eIP65 field housing\u003c\/strong\u003e for mounting outside the control cabinet.\u003c\/p\u003e\n\u003cp\u003eEach bridge signal goes to \u003cstrong\u003etwo galvanically isolated current outputs\u003c\/strong\u003e, so that a safety controller can check the channels against each other. The device is a safety component, not a measuring instrument: the redundancy comes from the two outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOne or two amplifiers\u003c\/strong\u003e sit in the same housing — with two bridges, two measuring points are monitored safely and independently of each other. The matching safety controller is the SCU-DR from the same range.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures of the SMM-HD\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e✅Sensor input: \u003cstrong\u003e1 or 2 × strain gauge full bridge 350 Ω\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Bridge sensitivity: up to \u003cstrong\u003e4 mV\/V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Bridge supply: 5 VDC\u003c\/p\u003e\n\u003cp\u003e✅Analog output: \u003cstrong\u003e2 × 4 … 20 mA per bridge\u003c\/strong\u003e, galvanically isolated\u003c\/p\u003e\n\u003cp\u003e✅Nominal range: 8 … 16 mA within 4 … 20 mA\u003c\/p\u003e\n\u003cp\u003e✅Load resistance: 500 Ω max.\u003c\/p\u003e\n\u003cp\u003e✅Test pulse input included\u003c\/p\u003e\n\u003cp\u003e✅Safety rating: \u003cstrong\u003eSIL3\u003c\/strong\u003e (EN 61508, EN 62061) · \u003cstrong\u003ePL e category 3\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Supply: 24 VDC ±10 %, 100 mA max.\u003c\/p\u003e\n\u003cp\u003e✅Housing: U-CASE 2 field housing\u003c\/p\u003e\n\u003cp\u003e✅Protection: \u003cstrong\u003eIP65\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Order numbers: 0600-00493 (one bridge) · 0600-00494 (two bridges)\u003c\/p\u003e","brand":"octogon Shop","offers":[{"title":"A full bridge (0600-00493)","offer_id":57265731404102,"sku":null,"price":904.0,"currency_code":"EUR","in_stock":true},{"title":"Two full bridges (0600-00494)","offer_id":57265731535174,"sku":null,"price":1729.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/ESMB_SMM-HD__product.png?v=1788560313"},{"product_id":"esmc-dms-bruecken-messverstaerker-sil1-ip65","title":"ESMC strain gauge bridge amplifier, SIL1, IP65","description":"\u003cp\u003e\u003cstrong\u003eStrain gauge bridge amplifier SMM-HD-SIL1\u003c\/strong\u003e with a \u003cstrong\u003ebuilt-in safety circuit\u003c\/strong\u003e for \u003cstrong\u003eSIL1\u003c\/strong\u003e and \u003cstrong\u003ePL c\u003c\/strong\u003e — in an IP65 field housing for mounting outside the control cabinet.\u003c\/p\u003e\n\u003cp\u003eThe difference to the SIL3 range: the safety function sits \u003cstrong\u003einside the device\u003c\/strong\u003e. A second amplifier, two comparators and a semiconductor relay watch the bridge independently of the measuring channel. \u003cstrong\u003eNo safety controller is required\u003c\/strong\u003e — the device switches by itself.\u003c\/p\u003e\n\u003cp\u003eThat makes the SMM-HD-SIL1 a usable measuring amplifier at the same time: \u003cstrong\u003e0.1 % of range\u003c\/strong\u003e plus sensor error, 24 bit resolution, output either 4 … 20 mA or 0 … 10 V.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures of the SMM-HD-SIL1\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e✅Sensor input: \u003cstrong\u003e1 × strain gauge full bridge 350 Ω\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Bridge sensitivity: up to \u003cstrong\u003e4 mV\/V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Bridge supply: 1.25 … 3 VDC\u003c\/p\u003e\n\u003cp\u003e✅Analog output: \u003cstrong\u003e4 … 20 mA or 0 … 10 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Accuracy: \u003cstrong\u003e0.1 % of range\u003c\/strong\u003e plus sensor error\u003c\/p\u003e\n\u003cp\u003e✅Resolution: \u003cstrong\u003e24 bit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Switching output: 30 VAC\/VDC, 500 mA max.\u003c\/p\u003e\n\u003cp\u003e✅Response time: 50 ms\u003c\/p\u003e\n\u003cp\u003e✅Safety rating: \u003cstrong\u003eSIL1 · PL c — built in\u003c\/strong\u003e, no safety controller required\u003c\/p\u003e\n\u003cp\u003e✅Housing: U-CASE 2 field housing\u003c\/p\u003e\n\u003cp\u003e✅Protection: \u003cstrong\u003eIP65\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Order key: Q X X X X - X X\u003c\/p\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57265732190534,"sku":null,"price":452.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/ESMC_SMM-HD-SIL1__product.png?v=1788560365"},{"product_id":"esme-dms-bruecken-messverstaerker-sil1-hutschiene","title":"ESME strain gauge bridge amplifier, SIL1, DIN rail","description":"\u003cp\u003e\u003cstrong\u003eStrain gauge bridge amplifier SMM-DR-SIL1\u003c\/strong\u003e with a \u003cstrong\u003ebuilt-in safety circuit\u003c\/strong\u003e for \u003cstrong\u003eSIL1\u003c\/strong\u003e and \u003cstrong\u003ePL c\u003c\/strong\u003e — in a DR22.5 DIN rail housing for the control cabinet.\u003c\/p\u003e\n\u003cp\u003eThe safety function sits \u003cstrong\u003einside the device\u003c\/strong\u003e: a second amplifier, two comparators and a semiconductor relay watch the bridge independently of the measuring channel. \u003cstrong\u003eNo safety controller is required\u003c\/strong\u003e — that is the difference to the SIL3 range, which does require one.\u003c\/p\u003e\n\u003cp\u003eA usable measuring amplifier at the same time: \u003cstrong\u003e0.1 % of range\u003c\/strong\u003e plus sensor error, 24 bit resolution, output either 4 … 20 mA or 0 … 10 V. The identical version in an IP65 field housing is the SMM-HD-SIL1.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures of the SMM-DR-SIL1\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e✅Sensor input: \u003cstrong\u003e1 × strain gauge full bridge 350 Ω\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Bridge sensitivity: up to \u003cstrong\u003e4 mV\/V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Bridge supply: 1.25 … 3 VDC\u003c\/p\u003e\n\u003cp\u003e✅Analog output: \u003cstrong\u003e4 … 20 mA or 0 … 10 V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Accuracy: \u003cstrong\u003e0.1 % of range\u003c\/strong\u003e plus sensor error\u003c\/p\u003e\n\u003cp\u003e✅Resolution: \u003cstrong\u003e24 bit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Switching output: 30 VAC\/VDC, 500 mA max.\u003c\/p\u003e\n\u003cp\u003e✅Response time: 50 ms\u003c\/p\u003e\n\u003cp\u003e✅Safety rating: \u003cstrong\u003eSIL1 · PL c — built in\u003c\/strong\u003e, no safety controller required\u003c\/p\u003e\n\u003cp\u003e✅Housing: DR22.5 for DIN rail\u003c\/p\u003e\n\u003cp\u003e✅Protection: IP20\u003c\/p\u003e\n\u003cp\u003e✅Order key: R A X X X - X X\u003c\/p\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57265732485446,"sku":null,"price":430.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/ESME_SMM-DR-SIL1__product.png?v=1788560461"},{"product_id":"esmd-programmierbare-sicherheitssteuerung-sil3","title":"ESMD programmable safety controller, SIL3","description":"\u003cp\u003e\u003cstrong\u003eProgrammable safety controller SCU-DR\u003c\/strong\u003e for \u003cstrong\u003eSIL3\u003c\/strong\u003e (IEC 61508) and \u003cstrong\u003ePL e\u003c\/strong\u003e (EN ISO 13849-1). This is the controller that the SIL3 amplifiers of this range require: it compares the two redundant channels of an SMM-DR or SMM-HD and takes the plant to its safe state on deviation.\u003c\/p\u003e\n\u003cp\u003eA logic device, not a measuring device. Freely programmable with up to \u003cstrong\u003e800 STL instructions\u003c\/strong\u003e, function-plan oriented, with \u003cstrong\u003ecross-fault detection\u003c\/strong\u003e and external contact monitoring (EMU).\u003c\/p\u003e\n\u003cp\u003eThe controller connects to the plant control system over fieldbus — besides interface modules, \u003cstrong\u003ePROFISAFE\u003c\/strong\u003e and \u003cstrong\u003eFSoE\u003c\/strong\u003e are available up to PL e and SIL3 respectively.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures of the SCU-DR\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e✅Safe digital inputs: \u003cstrong\u003e14\u003c\/strong\u003e, of which 10 OSSD\u003c\/p\u003e\n\u003cp\u003e✅Safe analog inputs: \u003cstrong\u003e2\u003c\/strong\u003e (plus 4 standard inputs)\u003c\/p\u003e\n\u003cp\u003e✅Relay outputs: \u003cstrong\u003e6\u003c\/strong\u003e, of which 3 safe\u003c\/p\u003e\n\u003cp\u003e✅Standard outputs: 2\u003c\/p\u003e\n\u003cp\u003e✅Pulse outputs: 2 with cross-fault detection\u003c\/p\u003e\n\u003cp\u003e✅Expansion: 2 modules plus fieldbus\u003c\/p\u003e\n\u003cp\u003e✅Programming: up to \u003cstrong\u003e800 STL instructions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅PFH: \u003cstrong\u003e3.0 · 10⁻⁹\u003c\/strong\u003e at category 4\u003c\/p\u003e\n\u003cp\u003e✅Safety rating: \u003cstrong\u003eSIL3\u003c\/strong\u003e (IEC 61508) · \u003cstrong\u003ePL e\u003c\/strong\u003e (EN ISO 13849-1)\u003c\/p\u003e\n\u003cp\u003e✅Supply: 24 VDC, −10 \/ +15 % · power 2.4 W\u003c\/p\u003e\n\u003cp\u003e✅Housing: DIN rail · protection IP20\u003c\/p\u003e\n\u003cp\u003e✅Versions: standard · \/F with FSoE (EtherCAT) · \/P with PROFISAFE (PROFINET)\u003c\/p\u003e\n\u003cp\u003e✅Order key: C R X X X X X X - X X X\u003c\/p\u003e","brand":"octogon Shop","offers":[{"title":"SCU-DR Standard","offer_id":57265734353222,"sku":null,"price":1234.0,"currency_code":"EUR","in_stock":true},{"title":"SCU-DR\/F with FSoE (EtherCAT)","offer_id":57265734418758,"sku":null,"price":2383.0,"currency_code":"EUR","in_stock":true},{"title":"SCU-DR\/P with PROFISAFE (PROFINET)","offer_id":57265734451526,"sku":null,"price":2383.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/ESMD_SCU-DR__product.png?v=1788560414"},{"product_id":"eomf-zweikanaliger-messumformer-pl-c","title":"EOMF two-channel transmitter, PL c","description":"\u003cp\u003eThe \u003cstrong\u003eEOMF\u003c\/strong\u003e is a two-channel measuring transducer with a built-in overload circuit of level \u003cstrong\u003ePL c \/ SIL 1\u003c\/strong\u003e, type \u003cstrong\u003eMEUTS-SIL\u003c\/strong\u003e, certified by TÜV Nord under number 44 799 14098202.\u003c\/p\u003e\n\u003cp\u003eIts special feature is the safety circuit: it has its \u003cstrong\u003eown amplifier\u003c\/strong\u003e and runs \u003cstrong\u003eparallel\u003c\/strong\u003e to the measurement chain of the IO-Link transducer – meaning the safety function is not dependent on the measurement chain. A solid-state relay opens if the switching point is exceeded, if the measuring amplifier's supply voltage is too low or missing, if there is a cable break on one or both signal lines, and if the safety circuit's own supply is too low or missing. \u003cstrong\u003eThe safe state is the open relay.\u003c\/strong\u003e The input is high-impedance biased to detect a cable break; two comparators – one for the measuring signal against the switching point, one for the bridge supply – are AND-linked.\u003c\/p\u003e\n\u003cp\u003eTwo \u003cstrong\u003elimit values\u003c\/strong\u003e can be set via IO-Link: the turn-on point from -7 to +7 mV, the turn-off point from -5 to +21 mV, with a switching accuracy of ± 50 µV and a \u003cstrong\u003ereaction time of a maximum of 10 ms\u003c\/strong\u003e. The switching load is a maximum of 30 VAC\/VDC at 500 mA. It is based on EN ISO 13849-1:2015 and EN 61508:2010.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChannel 1\u003c\/strong\u003e measures a full strain gauge bridge, dimensionless, from 350 Ω (two bridges from 2 × 700 Ω) with a bridge supply of 3 V. \u003cstrong\u003eChannel 2\u003c\/strong\u003e is universal, pre-set to °C, for \u003cstrong\u003ePt100\u003c\/strong\u003e in 3-wire circuit from -200 to 800 °C at 0.9 mA or a \u003cstrong\u003ethermocouple\u003c\/strong\u003e of type J (-210 … 1200 °C), type K (-200 … 1372 °C) or type N (-200 … 1300 °C). The range of both channels is freely adjustable in the range -3200.0 … +3200.0.\u003c\/p\u003e\n\u003cp\u003eThe output provides \u003cstrong\u003eIO-Link\u003c\/strong\u003e with level 0 \/ 24 V \u003cstrong\u003eand\u003c\/strong\u003e a current output \u003cstrong\u003e4 … 20 mA\u003c\/strong\u003e, which runs via input 1. The resolution is 16 bit on the strain gauge channel and 24 bit on the universal channel, with an accuracy of max. 0.05 % of the measuring range plus sensor error. Filter: 0.5 s for strain gauge, 25 s for temperature. Supply \u003cstrong\u003e24 VDC\u003c\/strong\u003e at under 30 mA in standard operation, maximum 130 mA total current.\u003c\/p\u003e\n\u003cp\u003eThe board measures \u003cstrong\u003e21 × 76.95 × 4.2 mm\u003c\/strong\u003e and weighs approximately 7.6 g, material FR4 and PBT, connection via solder pads 2.7 × 1.5 mm, mounting position optional, operating range \u003cstrong\u003e-20 °C to +80 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThree mounting requirements and the enabling of the limit values must be read before the housing is closed.\u003c\/strong\u003e The board must be installed in the sensor housing to at least \u003cstrong\u003eIP54\u003c\/strong\u003e and protected against vibrations; the safety circuit must be regularly checked for function, the manufacturer recommends \u003cstrong\u003etwo years\u003c\/strong\u003e, and the limit values must be checked before commissioning. To set the limit values via IO-Link, a \u003cstrong\u003ephototransistor\u003c\/strong\u003e (SFH 309 or similar) must be connected and illuminated; thereafter, the settings must be read back and the phototransistor darkened – in normal operation, it must be covered in such a way that unintentional illumination is excluded.\u003c\/p\u003e\n\u003cp\u003eAn \u003cstrong\u003eIO-Link master\u003c\/strong\u003e is required for configuration and operation, as well as the IODD file from the IODD finder. The board has been tested according to EN 61000-6-2:2005 and EN 61000-6-4:2007. A CE mark is not documented in the manufacturer's data sheet; a declaration of conformity must be requested before placing on the market in the EU. The version without safety function is the \u003cstrong\u003eEOME\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRegarding price:\u003c\/strong\u003e The price applies to the basic version of the board. Measuring ranges and limit values are adjustable via IO-Link, so factory programming is not required. If you would like the board \u003cstrong\u003efactory-programmed to your measuring ranges and switching points\u003c\/strong\u003e, this is possible at an additional cost — \u003ca href=\"\/en\/pages\/contact\"\u003eplease ask us\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eOverload circuit PL c \/ SIL 1, TÜV Nord 44 799 14098202\u003c\/li\u003e\n\n\u003cli\u003eSafety circuit with its own amplifier, parallel to the measuring chain\u003c\/li\u003e\n\n\u003cli\u003eRelay also opens in case of cable break and undervoltage – safe state is open\u003c\/li\u003e\n\n\u003cli\u003eTwo limit values adjustable via IO-Link, reaction time max. 10 ms\u003c\/li\u003e\n\n\u003cli\u003eOutputs IO-Link and 4 … 20 mA\u003c\/li\u003e\n\n\u003cli\u003eChannel 1 full strain gauge bridge, Channel 2 Pt100 or thermocouple\u003c\/li\u003e\n\n\u003cli\u003eResolution 16 bit strain gauge, 24 bit universal, accuracy max. 0.05 %\u003c\/li\u003e\n\n\u003cli\u003e21 × 76.95 × 4.2 mm, approx. 7.6 g, operating range -20 … +80 °C\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57306259620166,"sku":null,"price":369.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/EOMF_MEUTS-SIL_titelbild_b1ff3cac-f6c1-4f9f-be9f-e3eea90af3e2.webp?v=1788951931"}],"url":"https:\/\/octogon.org\/en\/collections\/measurement-electronics-sil-pl.oembed","provider":"octogon GmbH","version":"1.0","type":"link"}