{"title":"IO-Link sensors and measuring electronics","description":"\u003cp\u003e\u003cstrong\u003eIO-Link sensors and measuring electronics for force and weighing\u003c\/strong\u003e bring readings digitally from the sensor into the control system, via an unshielded standard cable and M12 connector, without an analog card and independently of the fieldbus above. You will find strain gauge amplifiers here as well as force transducers and load cells with directly integrated IO-Link electronics.\u003c\/p\u003e\n\u003ch2\u003eWhat IO-Link is\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003eIO-Link is a vendor-independent, standardized point-to-point connection between a sensor or actuator and an IO-Link master, defined in IEC 61131-9. The master sits in the control cabinet or as a field module in the plant and is in turn connected to the fieldbus.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe decisive point: IO-Link is fieldbus-independent. Whether PROFINET, EtherCAT or another protocol runs above the master makes no difference to the sensor. You can use the same sensor type in plants with different control architectures, which considerably simplifies spare parts management and standardization in machine building. We explain the basics and the setup in detail on our page on \u003ca href=\"\/en\/pages\/io-link\"\u003eIO-Link\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe connection itself runs over an unshielded three-wire standard cable with an M12 connector, usually up to 20 m. No shielded measuring cables, no special routing rules, no analog input card.\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003eThree channels in one cable: IO-Link sensors and measuring electronics\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003eUnlike an analog signal, IO-Link transmits not just one value but three types of information:\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eProcess data\u003c\/strong\u003e is transmitted cyclically: the actual measured value and the associated status bits.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eParameter and service data\u003c\/strong\u003e is exchanged acyclically when needed. This is how you set the measuring range, zero point, filter and limit values – from the engineering tool rather than on the device.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eEvents\u003c\/strong\u003e are reported by the device on its own, such as a wire break, a sensor fault or a limit value being exceeded. An analog signal cannot do this; all you are left with there is an implausible value that the control system has to interpret.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eWhat this changes in operation\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eWiring.\u003c\/strong\u003e A single standard sensor cable type for all devices instead of shielded measuring cables, analog lines and separate power supplies. This reduces sources of error during installation and the effort for documentation.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eParameterization.\u003c\/strong\u003e Settings no longer live in the device but in the project. They are documented, reproducible and can be rolled out identically for an entire machine series.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eDevice replacement without rework.\u003c\/strong\u003e This is the advantage you only learn to appreciate when service is needed. The master stores the parameters and automatically loads them into the replacement device. Changing a sensor thus becomes a mechanical task that maintenance staff can carry out without any knowledge of measurement technology. With analog evaluation, the system would instead have to be rescaled or recalibrated with test weights.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eDiagnostics and statistics.\u003c\/strong\u003e Depending on the device, IO-Link also supplies minimum, maximum, peak value, an operating hours counter or a load spectrum. This lets you assess whether a press or a hoist is operated within its design limits, and a brief overload remains visible that would long since have disappeared from the cyclic process value.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eWhat we offer with IO-Link\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e\u003ca href=\"\/en\/collections\/io-link-dms-messverstaerker\"\u003eStrain gauge amplifiers\u003c\/a\u003e.\u003c\/strong\u003e A compact module close to the sensor turns any existing strain gauge full bridge into an IO-Link device. The route for retrofits and for applications where the sensor type is fixed.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eForce transducers and load cells with integrated electronics.\u003c\/strong\u003e Here the amplifier sits in the sensor housing; there is only one device and one cable. More compact and more robust, the better choice for new designs. Our \u003ca href=\"\/en\/collections\/waegezellen-kraftaufnehmer\"\u003eload cells and force transducers\u003c\/a\u003e can be equipped with IO-Link in this way.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCustom sensors with IO-Link.\u003c\/strong\u003e If no standard design fits, we develop the \u003ca href=\"\/en\/pages\/kundenspezifische-kraftaufnehmer-kraftmessdosen\"\u003etransducer to your specifications\u003c\/a\u003e and integrate the interface at the same time. Design, manufacturing, strain gauge installation and electronics are all done in-house.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eCommissioning\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eEvery device comes with an IODD file, the standardized device description. You load it into your engineering tool, after which all parameters and process data are available with names and units. You set scaling, zero point and filter there, not on the device. No opening of housings, no potentiometers, no DIP switches.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe IODD file, data sheet and CAD model are available for download with every item.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eWhen IO-Link is the right choice, and when it is not\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eIn favor:\u003c\/strong\u003e several measuring points on one machine, high requirements for reproducibility and documentation, series machine building, plants with frequent sensor replacement, a need for diagnostic and condition data, and any situation where no analog card is free.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eAgainst:\u003c\/strong\u003e fast dynamic measurements, because IO-Link transmits cyclically in the millisecond range. For a force curve during impact or joining processes, use a \u003ca href=\"\/en\/collections\/dms-messverstaerker\"\u003estrain gauge amplifier\u003c\/a\u003e with the corresponding bandwidth. Long distances, because IO-Link is a point-to-point connection with a limited cable length; for the route from the silo to the control room, a \u003ca href=\"\/en\/collections\/waegetransmitter\"\u003eweight transmitter\u003c\/a\u003e with a bus or analog output is more suitable. And a single weighing point without an existing master, because the infrastructure then does not pay off.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eIO-Link is not intended for legal-for-trade use; there, \u003ca href=\"\/en\/collections\/waegeindikatoren\"\u003eweighing indicators\u003c\/a\u003e with the corresponding approval are the way to go.\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003eMatching components\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003eFurther evaluation electronics can be found under \u003ca href=\"\/en\/collections\/messelektronik\"\u003emeasuring electronics\u003c\/a\u003e, and information on fieldbuses on our \u003ca href=\"\/en\/pages\/profinet\"\u003efieldbus page\u003c\/a\u003e. So that you measure in newtons or kilograms rather than in mV\/V, we calibrate the measuring chain \u003ca href=\"\/en\/pages\/kalibrierung-waegezelle-kraftmessdose-kraftaufnehmer-iso17025\"\u003eto ISO 17025\u003c\/a\u003e in our own laboratory on request.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eOur engineers will advise you directly on choosing the sensor, interface and scaling.\u003c\/p\u003e","products":[{"product_id":"etlg-waegetransmitter-analog-und-profinet-io","title":"ETLG weight transmitter, analog and ProfiNet-IO","description":"\u003cp\u003e\u003cstrong\u003eWeight transmitters\u003c\/strong\u003e with \u003cstrong\u003eanalog and ProfiNet-IO\u003c\/strong\u003e output serve as the interface between the \u003cstrong\u003eload cell\u003c\/strong\u003e, \u003cstrong\u003eweighing platform\u003c\/strong\u003e or other \u003cstrong\u003estrain gauge sensors\u003c\/strong\u003e and a \u003cstrong\u003ePLC unit \u003c\/strong\u003ein industrial applications. Weight transmitter indicator with 6-digit red LED display (8 mm digit height). Compact design with space-saving narrow construction.  4 buttons for system calibration. 6 indicator LEDs. Dimensions: 25 x 115 x 120 mm.\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures of the weight transmitters\u003cbr\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e✅Weight transmitter for mounting on the rear wall of the control panel on\u003cbr\u003eOmega\/DIN rail\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✅6-digit semi-alphanumeric red LED display\u003cbr\u003e(8 mm digit height)\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e✅RS485 serial interface for communication via\u003cbr\u003eModBus RTU, ASCII or continuous unidirectional\u003cbr\u003etransmission protocols\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✅3 relay outputs controlled by setpoints or via protocols\u003c\/p\u003e\n\u003cp\u003e✅2 opto-isolated digital PNP inputs: status readout via serial\u003cbr\u003ecommunication protocols\u003c\/p\u003e\n\u003cp\u003e✅1 load cell input\u003c\/p\u003e\n\u003cp\u003e✅The analog output provides:\u003cbr\u003eCurrent signal: 0...20 mA; 4...20 mA (up to 300 ohm)\u003cbr\u003eVoltage signal: 0...10 V; 0...5 V; ±10 V; ±5 V (min. 10k ohm)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/L-TLB_Datenblatt.pdf?v=1711463053\" style=\"color: #d84f1b;\" title=\"octogon Shop\" rel=\"noopener\" target=\"_blank\"\u003eDatasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCAD model:\u003cbr\u003e\u003ca rel=\"noopener\" title=\"octogon Shop\" style=\"color: #d84f1b;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TLB.stp?v=1712652129\" target=\"_blank\"\u003e3D data\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"octogon Shop","offers":[{"title":"4...20mA; 0...10V; ±10V","offer_id":49312646660422,"sku":"","price":220.0,"currency_code":"EUR","in_stock":true},{"title":"Profinet","offer_id":49312646693190,"sku":"","price":418.0,"currency_code":"EUR","in_stock":true},{"title":"EtherCAT","offer_id":49312646725958,"sku":"","price":451.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/ETLG_TLB__product_freigestellt.png?v=1786622909"},{"product_id":"emma-io-link-dms-messverstaerker","title":"EMMA IO-Link strain gauge amplifier","description":"\u003cp\u003e\u003cstrong\u003eIO-Link strain gauge amplifiers EPG-IO\u003c\/strong\u003e for load cells offer various advantages in industrial applications. The combination of IO-Link and strain gauge amplifiers optimizes \u003cstrong\u003edata acquisition and data transmission\u003c\/strong\u003e in load cell applications, resulting in improved process control and efficiency.\u003c\/p\u003e\n\u003cp\u003eThe strain gauge measuring amplifier has a robust plastic housing and is suitable for a wide range of industrial applications.\u003c\/p\u003e\n\u003cp\u003eThis has a connection for a \u003cstrong\u003estrain gauge full bridge\u003c\/strong\u003e. The sensor signal from the application is converted into a standardized IO-Link signal by the measuring amplifier. The measuring transducer uses its power supply to apply a measuring current to the strain gauge bridge. The output signal of the bridge changes proportionally to the change in force and is passed on by the IO-Link interface as a digital signal.\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures of the EPG-IO IO-Link strain gauge amplifier\u003cbr\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e✅Input: \u003cstrong\u003e1 DMS full bridge\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Measuring range: freely adjustable in the range -32000...+32000\u003c\/p\u003e\n\u003cp\u003e✅Combined error \u003cstrong\u003e\u0026lt;±0.05%\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Output: \u003cstrong\u003eIO-Link\u003c\/strong\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e✅Resolution: \u003cstrong\u003e16 bit\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✅Strain gauge supply: 3 VDC\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e✅Dimensions: 72x28x35 mm (without electrical connection)\u003c\/p\u003e\n\u003cp\u003e✅Protection class: \u003cstrong\u003eat least IP65\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e✅Compatible with other manufacturers\u003c\/p\u003e\n\u003cp\u003e\u0026nbsp;\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/IO-Link_DMS_Messverstaerker_EPG-IO.pdf?v=1711460776\" title=\"octogon Shop\" style=\"color: #d84f1b;\"\u003eDatasheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"octogon Shop","offers":[{"title":"traction sensor","offer_id":49469983719750,"sku":"","price":261.0,"currency_code":"EUR","in_stock":true},{"title":"pressure force sensor","offer_id":49469983752518,"sku":"","price":261.0,"currency_code":"EUR","in_stock":true},{"title":"tension\/compression force sensor","offer_id":49469983785286,"sku":"","price":261.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/IO-Link_EPG-IO.png?v=1713777034"},{"product_id":"lboa-io-scher-und-biegestab-waegezelle-mit-io-link","title":"LBOA-IO shear and bending beam load cell with IO-Link","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eLBOA-IO\u003c\/strong\u003e is a precise shear and bending beam load cell with an integrated \u003cstrong\u003eIO-Link interface\u003c\/strong\u003e for industrial weighing and force measurement applications. It is suitable for tensile and compressive forces and is available in measuring ranges from \u003cstrong\u003e50 kg to 10,000 kg\u003c\/strong\u003e or optionally from \u003cstrong\u003e500 N to 100 kN\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIn addition to digital measured value transmission via IO-Link, an analog \u003cstrong\u003e4-20 mA signal\u003c\/strong\u003e is available in SIO mode. Configurable switching points enable direct monitoring of limit values.\u003c\/p\u003e\n\u003cp\u003eWith a total error of maximum \u003cstrong\u003e±0.02 % FS\u003c\/strong\u003e, a robust stainless steel housing made of \u003cstrong\u003e17-4PH \/ 1.4542\u003c\/strong\u003e and protection class \u003cstrong\u003eIP67\u003c\/strong\u003e, the load cell is suitable for demanding industrial environments. ISO 17025 calibration is optionally available.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eIO-Link 1.1 and analog 4-20 mA output\u003c\/li\u003e\n\n\u003cli\u003eMeasuring ranges up to 10,000 kg or 100 kN\u003c\/li\u003e\n\n\u003cli\u003eTotal error ≤ ±0.02 % FS\u003c\/li\u003e\n\n\u003cli\u003eFor tensile and compressive force measurements\u003c\/li\u003e\n\n\u003cli\u003eStainless steel housing made of 17-4PH \/ 1.4542\u003c\/li\u003e\n\n\u003cli\u003eProtection class IP67\u003c\/li\u003e\n\n\u003cli\u003eConfigurable switching points\u003c\/li\u003e\n\n\u003cli\u003eOptional with ISO 17025 calibration\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"50 kg","offer_id":56755182829894,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"75 kg","offer_id":56755182862662,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"150 kg","offer_id":56755182895430,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"300 kg","offer_id":56755182928198,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"500 kg","offer_id":56755182960966,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"750 kg","offer_id":56755182993734,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"1 t","offer_id":56755183026502,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"1.5 tons","offer_id":56755183059270,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"2 t","offer_id":56755183092038,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"5 t","offer_id":56755183124806,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"7.5 t","offer_id":56755183157574,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"10 t","offer_id":56755183190342,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"500 N","offer_id":56755183223110,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"750 N","offer_id":56755183255878,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"1.5 kN","offer_id":56755183288646,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"3 kN","offer_id":56755183321414,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"5 kN","offer_id":56755183354182,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"7.5 kN","offer_id":56755183386950,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"10 kN","offer_id":56755183419718,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"15 kN","offer_id":56755183452486,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"20 kN","offer_id":56755183485254,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"50 kN","offer_id":56755183518022,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"75 kN","offer_id":56755183550790,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true},{"title":"100 kN","offer_id":56755183583558,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/LBOA-IO.webp?v=1782212964"},{"product_id":"qtka-turbinen-durchflussmesser-mit-lcd-anzeige","title":"QTKA turbine flowmeter with LCD display","description":"\u003cp\u003eThe \u003cstrong\u003eQTKA\u003c\/strong\u003e is an electronic turbine flowmeter for liquids in nominal sizes from DN 6 to DN 300. It is particularly suited to oil or water where switch points, an analog value, pulses and a digital interface are to come from one device.\u003c\/p\u003e\u003cp\u003eTurbine principle, measuring range \u003cstrong\u003eDN 6 … DN 300\u003c\/strong\u003e with flow rates of \u003cstrong\u003e0.04 … 1800 m³\/h\u003c\/strong\u003e by size, accuracy \u003cstrong\u003e≤ ±1.0 % of the measuring range\u003c\/strong\u003e, switching accuracy and analog output accuracy each \u003cstrong\u003e≤ ±0.5 %\u003c\/strong\u003e of the range. Outputs: switch, analog, pulse and frequency plus \u003cstrong\u003eIO-Link\u003c\/strong\u003e and \u003cstrong\u003eRS485\u003c\/strong\u003e, switching load \u0026lt; 200 mA. Supply \u003cstrong\u003e12 … 30 V DC\u003c\/strong\u003e, response time 10 ms … 5 s (factory default 1 s), connection \u003cstrong\u003eM12 × 1\u003c\/strong\u003e, 5-pin. The liquid crystal display shows four values.\u003c\/p\u003e\u003cp\u003eShell of stainless steel 304, display head of stainless steel or engineering plastic, turbine rotor of 3cr13 or 2205. Nominal pressure PN 6.3 · 16 · 25 · 40 MPa up to DN32, 2.5 MPa up to DN100, 1.6 MPa up to DN300; max. pressure loss 0.05 MPa at DN10 down to 0.025 MPa up to DN300. Medium temperature -30 … +100 °C, +130 °C type H, +180 °C type H1; ambient -10 … +70 °C; viscosity \u0026gt; 5 × 10⁻⁶ m²\/s; protection \u003cstrong\u003eIP67\u003c\/strong\u003e. A declaration of conformity is not documented in the datasheet. Before sizing, note: the maximum flow of 222 m³\/h at DN100 breaks the series of its neighbours 100 and 250 and has to be settled with the enquiry.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eTurbine principle for DN 6 … DN 300\u003c\/li\u003e\u003cli\u003eAccuracy ≤ ±1.0 % of the measuring range\u003c\/li\u003e\u003cli\u003eSwitch, analog, pulse and frequency output\u003c\/li\u003e\u003cli\u003eIO-Link and RS485\u003c\/li\u003e\u003cli\u003eLiquid crystal display with four values\u003c\/li\u003e\u003cli\u003eResponse time 10 ms … 5 s, factory default 1 s\u003c\/li\u003e\u003cli\u003eMedium temperature up to +180 °C in version H1\u003c\/li\u003e\u003cli\u003eProtection IP67\u003c\/li\u003e\u003cli\u003eReverse polarity, overload and short-circuit protection\u003c\/li\u003e\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57266204737862,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/QTKA_produkt.webp?v=1790331902"},{"product_id":"eomc-io-link-messumformer","title":"EOMC IO-Link transmitter","description":"\u003cp\u003eThe \u003cstrong\u003eEOMC\u003c\/strong\u003e is a single-channel IO-Link transducer as an OEM board, type \u003cstrong\u003eMCUT-E\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt converts the signal from a full strain gauge bridge into a digital measured value – for force and pressure. The measuring range is freely adjustable and \u003cstrong\u003eunitless\u003c\/strong\u003e: the board adopts the unit of the application, whether Newton, kilogram, or bar. Since the value is transmitted via IO-Link, configuration, diagnosis, and device replacement are possible without recalibration.\u003c\/p\u003e\n\u003cp\u003eThe channel accepts \u003cstrong\u003e1 × full strain gauge bridge\u003c\/strong\u003e from 350 Ω, with two parallel full bridges at least 2 × 700 Ω; further bridges are possible, the minimum resistance increases accordingly. The bridge supply provides \u003cstrong\u003e3 V\u003c\/strong\u003e. The measuring range is freely adjustable in the range of \u003cstrong\u003e-3200.0 … +3200.0\u003c\/strong\u003e. The resolution is \u003cstrong\u003e16 bit\u003c\/strong\u003e, the accuracy is \u003cstrong\u003emax. 0.05 % of the measuring range\u003c\/strong\u003e plus sensor error. The filter is 0.5 s, the power-on delay is less than 5 s, and the response time is \u003cstrong\u003e20 ms\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe output has an \u003cstrong\u003eIO-Link interface\u003c\/strong\u003e with a signal level of 0 \/ 24 V according to IO-Link specification. The board is powered with \u003cstrong\u003e24 VDC\u003c\/strong\u003e at less than 30 mA in standard operation, a maximum total current of 130 mA; the switching current in SIO mode is a maximum of 100 mA. Polarity reversal is protected – no function, no destruction.\u003c\/p\u003e\n\u003cp\u003eThe board measures \u003cstrong\u003e40 × 17 × 4.5 mm\u003c\/strong\u003e and weighs approximately 6.5 g, material FR4 and PBT, connection via solder pads 2.7 × 1.5 mm, mounting position arbitrary. The operating range is from \u003cstrong\u003e-20 °C to +80 °C\u003c\/strong\u003e, the storage temperature from -20 °C to +85 °C.\u003c\/p\u003e\n\u003cp\u003eAn \u003cstrong\u003eIO-Link master\u003c\/strong\u003e is required for configuration and operation, as well as the appropriate IODD file from the IODD Finder. The board has \u003cstrong\u003eIP00\u003c\/strong\u003e and must be installed in a housing. It has been tested according to EN 61000-6-2:2005 and EN 61000-6-4:2007 + A1:2011. A CE mark is not documented in the manufacturer's data sheet, a declaration of conformity must be requested before placing it on the market in the EU. This board has \u003cstrong\u003eone\u003c\/strong\u003e channel and no temperature input; the two-channel version with a universal channel is the \u003cstrong\u003eEOME\u003c\/strong\u003e, the round design is the \u003cstrong\u003eEOMD\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRegarding the price:\u003c\/strong\u003e The price applies to the board in its basic configuration. The measuring range is freely adjustable via IO-Link, so factory programming is not required. If you still wish to have the board \u003cstrong\u003efactory programmed to your measuring range\u003c\/strong\u003e, this is possible at an extra charge — \u003ca href=\"\/en\/pages\/contact\"\u003eplease ask us about it\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eSingle-channel IO-Link transducer for full strain gauge bridge\u003c\/li\u003e\n\n\u003cli\u003eMeasuring range unitless and freely adjustable, -3200.0 … +3200.0\u003c\/li\u003e\n\n\u003cli\u003eResolution 16 bit, accuracy max. 0.05 % of measuring range\u003c\/li\u003e\n\n\u003cli\u003eResponse time 20 ms, filter 0.5 s\u003c\/li\u003e\n\n\u003cli\u003eOnly 40 × 17 × 4.5 mm, weight approx. 6.5 g\u003c\/li\u003e\n\n\u003cli\u003eBridge supply 3 V, from 350 Ω, multiple bridges possible\u003c\/li\u003e\n\n\u003cli\u003eSupply 24 VDC, standard current less than 30 mA\u003c\/li\u003e\n\n\u003cli\u003eOperating range -20 … +80 °C\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57306257588550,"sku":null,"price":89.09,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/EOMC_MCUT-E_titelbild_13a387df-4d02-40e2-8f04-62fb467c4bc8.webp?v=1788951907"},{"product_id":"eomd-io-link-messumformer-rund","title":"EOMD IO-Link transmitter, round","description":"\u003cp\u003eThe \u003cstrong\u003eEOMD\u003c\/strong\u003e is a single-channel IO-Link transducer as a \u003cstrong\u003eround\u003c\/strong\u003e OEM board, type \u003cstrong\u003eMCUT-R\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eElectrically, it is the \u003cstrong\u003eEOMC\u003c\/strong\u003e, but in a round design: \u003cstrong\u003eØ 31.4 mm with a height of 4.8 mm\u003c\/strong\u003e, with an \u003cstrong\u003eØ 8 mm\u003c\/strong\u003e mounting hole in the center. This shape is intended for sensors with a round housing – a load cell, a pressure transducer, a round housing with cable feed-through in the axis.\u003c\/p\u003e\n\u003cp\u003eIt converts the signal from a strain gauge full bridge into a digital measured value for force and pressure. The measuring range is freely adjustable in the range of \u003cstrong\u003e-3200.0 … +3200.0\u003c\/strong\u003e and is \u003cstrong\u003eunitless\u003c\/strong\u003e, meaning the board adopts the unit of the application. The channel accepts \u003cstrong\u003e1 × strain gauge full bridge\u003c\/strong\u003e from 350 Ω, for two parallel full bridges at least 2 × 700 Ω; the bridge supply provides \u003cstrong\u003e3 V\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe resolution is \u003cstrong\u003e16 bit\u003c\/strong\u003e, the accuracy is \u003cstrong\u003emax. 0.05% of the measuring range\u003c\/strong\u003e plus sensor error. The filter is 0.5 s, the power-on delay is less than 5 s, and the response time is \u003cstrong\u003e20 ms\u003c\/strong\u003e. An \u003cstrong\u003eIO-Link interface\u003c\/strong\u003e with a signal level of 0 \/ 24 V is available at the output. The board is supplied with \u003cstrong\u003e24 VDC\u003c\/strong\u003e at under 30 mA in standard operation, maximum 130 mA total current; reverse polarity is protected.\u003c\/p\u003e\n\u003cp\u003eThe weight is approx. 3.5 g, material FR4 and PBT, connection via solder pads 2.7 × 1.5 mm, mounting position arbitrary. The operating range extends from \u003cstrong\u003e-20 °C to +80 °C\u003c\/strong\u003e, the storage temperature from -20 °C to +85 °C.\u003c\/p\u003e\n\u003cp\u003eAn \u003cstrong\u003eIO-Link master\u003c\/strong\u003e is required for configuration and operation, as well as the appropriate IODD file from the IODD Finder. The board has \u003cstrong\u003eIP00\u003c\/strong\u003e and must be installed in a housing. It has been tested according to EN 61000-6-2:2005 and EN 61000-6-4:2007 + A1:2011. A CE mark is not documented in the manufacturer's datasheet; a declaration of conformity must be requested before placing it on the market in the EU. This board has one channel and no temperature input.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRegarding the price:\u003c\/strong\u003e The price is for the board in its basic configuration. The measuring range is freely adjustable via IO-Link, so factory programming is not required. If you still wish to have the board \u003cstrong\u003epre-programmed to your measuring range at the factory\u003c\/strong\u003e, this is possible for an additional charge — \u003ca href=\"\/en\/pages\/contact\"\u003eplease ask us\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eRound OEM board Ø 31.4 × 4.8 mm with Ø 8 mm hole\u003c\/li\u003e\n\n\u003cli\u003eSingle-channel IO-Link transducer for strain gauge full bridge\u003c\/li\u003e\n\n\u003cli\u003eMeasuring range unitless and freely adjustable, -3200.0 … +3200.0\u003c\/li\u003e\n\n\u003cli\u003eResolution 16 bit, accuracy max. 0.05% of measuring range\u003c\/li\u003e\n\n\u003cli\u003eResponse time 20 ms, filter 0.5 s\u003c\/li\u003e\n\n\u003cli\u003eWeight only approx. 3.5 g\u003c\/li\u003e\n\n\u003cli\u003eSupply 24 VDC, standard current under 30 mA\u003c\/li\u003e\n\n\u003cli\u003eOperating range -20 … +80 °C\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57306258768198,"sku":null,"price":89.09,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/EOMD_MCUT-R_titelbild_9597ba0b-f441-4303-a424-58a6c4a023c2.webp?v=1788951906"},{"product_id":"eome-zweikanaliger-io-link-messumformer","title":"EOME two-channel IO-Link transmitter","description":"\u003cp\u003eThe \u003cstrong\u003eEOME\u003c\/strong\u003e is a two-channel IO-Link transducer as an OEM board, type \u003cstrong\u003eMEUT-E\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChannel 1\u003c\/strong\u003e measures a strain gauge full bridge, \u003cstrong\u003eChannel 2\u003c\/strong\u003e a temperature sensor – and both measured values are transmitted via a common IO-Link interface. This is the case for which this board is built: force or pressure and the corresponding temperature from one device, with one cable and one master port.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe universal channel does not support strain gauge bridges.\u003c\/strong\u003e The datasheet lists them in the sensor list, but states below that strain gauge applications for the universal channel are not yet supported. If you need \u003cem\u003etwo\u003c\/em\u003e force channels, you cannot use this board for that today.\u003c\/p\u003e\n\u003cp\u003eChannel 1 accepts a \u003cstrong\u003estrain gauge full bridge\u003c\/strong\u003e from 350 Ω, with two bridges at least 2 × 700 Ω, with a bridge supply of \u003cstrong\u003e3 V\u003c\/strong\u003e; the unit of measurement is dimensionless. Channel 2 is preset to °C and accepts \u003cstrong\u003ePt100\u003c\/strong\u003e in a 3-wire circuit from -200 to 800 °C at 0.9 mA sensor current or a \u003cstrong\u003ethermocouple\u003c\/strong\u003e of type J (-210 ... 1200 °C), type K (-200 ... 1372 °C) or type N (-200 ... 1300 °C). The measuring range of both channels can be freely set in the range -3200.0 ... +3200.0.\u003c\/p\u003e\n\u003cp\u003eThe resolution is \u003cstrong\u003e16 bit on the strain gauge channel and 24 bit on the universal channel\u003c\/strong\u003e, the accuracy max. \u003cstrong\u003e0.05% of the measuring range\u003c\/strong\u003e plus sensor error. The filters are separate: 0.5 s for strain gauge, 25 s for temperature. The power-on delay is less than 5 s, the response time is 20 ms. The board is supplied with \u003cstrong\u003e24 VDC\u003c\/strong\u003e at less than 30 mA in standard operation, maximum 130 mA total current; reverse polarity is protected.\u003c\/p\u003e\n\u003cp\u003eThe board measures \u003cstrong\u003e40 × 17 × 8.25 mm\u003c\/strong\u003e and weighs about 6.5 g. The height comes from the construction: It consists of \u003cstrong\u003etwo stacked boards\u003c\/strong\u003e. The single-channel version with the same outline is only 4.5 mm high. Material FR4 and PBT, connection via solder pads 2.7 × 1.5 mm, installation position arbitrary, operating range \u003cstrong\u003e-20 °C to +80 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAn \u003cstrong\u003eIO-Link master\u003c\/strong\u003e is required for configuration and operation, as well as the appropriate IODD file from the IODD Finder. The board has \u003cstrong\u003eIP00\u003c\/strong\u003e and must be installed in a housing. It has been tested according to EN 61000-6-2:2005 and EN 61000-6-4:2007 + A1:2011. A CE mark is not documented in the manufacturer's datasheet; a declaration of conformity must be requested before placing it on the market in the EU. A version with integrated safety function PL c \/ SIL 1 is the \u003cstrong\u003eEOMF\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRegarding the price:\u003c\/strong\u003e The price is for the board in its basic version. The measuring ranges of both channels are freely adjustable via IO-Link, so factory programming is not required. However, if you wish to have the board \u003cstrong\u003eprogrammed to your measuring ranges at the factory\u003c\/strong\u003e, this is possible at an additional cost — \u003ca href=\"\/en\/pages\/contact\"\u003eplease ask us about it\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eTwo channels on one board: strain gauge full bridge and temperature sensor\u003c\/li\u003e\n\n\u003cli\u003eChannel 2 for Pt100 (3-wire) or thermocouple type J, K and N\u003c\/li\u003e\n\n\u003cli\u003eResolution 16 bit on the strain gauge channel, 24 bit on the universal channel\u003c\/li\u003e\n\n\u003cli\u003eAccuracy max. 0.05% of the measuring range\u003c\/li\u003e\n\n\u003cli\u003eSeparate filters: 0.5 s for strain gauge, 25 s for temperature\u003c\/li\u003e\n\n\u003cli\u003eBoth measured values via one IO-Link interface\u003c\/li\u003e\n\n\u003cli\u003e40 × 17 × 8.25 mm, two stacked boards, approx. 6.5 g\u003c\/li\u003e\n\n\u003cli\u003eOperating range -20 ... +80 °C\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57306259030342,"sku":null,"price":134.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/EOME_MEUT-E_titelbild_961c1f67-c557-4ccc-a316-d76c0bc0d343.webp?v=1788951931"},{"product_id":"eomf-zweikanaliger-messumformer-pl-c","title":"EOMF two-channel transmitter, PL c","description":"\u003cp\u003eThe \u003cstrong\u003eEOMF\u003c\/strong\u003e is a two-channel measuring transducer with a built-in overload circuit of level \u003cstrong\u003ePL c \/ SIL 1\u003c\/strong\u003e, type \u003cstrong\u003eMEUTS-SIL\u003c\/strong\u003e, certified by TÜV Nord under number 44 799 14098202.\u003c\/p\u003e\n\u003cp\u003eIts special feature is the safety circuit: it has its \u003cstrong\u003eown amplifier\u003c\/strong\u003e and runs \u003cstrong\u003eparallel\u003c\/strong\u003e to the measurement chain of the IO-Link transducer – meaning the safety function is not dependent on the measurement chain. A solid-state relay opens if the switching point is exceeded, if the measuring amplifier's supply voltage is too low or missing, if there is a cable break on one or both signal lines, and if the safety circuit's own supply is too low or missing. \u003cstrong\u003eThe safe state is the open relay.\u003c\/strong\u003e The input is high-impedance biased to detect a cable break; two comparators – one for the measuring signal against the switching point, one for the bridge supply – are AND-linked.\u003c\/p\u003e\n\u003cp\u003eTwo \u003cstrong\u003elimit values\u003c\/strong\u003e can be set via IO-Link: the turn-on point from -7 to +7 mV, the turn-off point from -5 to +21 mV, with a switching accuracy of ± 50 µV and a \u003cstrong\u003ereaction time of a maximum of 10 ms\u003c\/strong\u003e. The switching load is a maximum of 30 VAC\/VDC at 500 mA. It is based on EN ISO 13849-1:2015 and EN 61508:2010.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChannel 1\u003c\/strong\u003e measures a full strain gauge bridge, dimensionless, from 350 Ω (two bridges from 2 × 700 Ω) with a bridge supply of 3 V. \u003cstrong\u003eChannel 2\u003c\/strong\u003e is universal, pre-set to °C, for \u003cstrong\u003ePt100\u003c\/strong\u003e in 3-wire circuit from -200 to 800 °C at 0.9 mA or a \u003cstrong\u003ethermocouple\u003c\/strong\u003e of type J (-210 … 1200 °C), type K (-200 … 1372 °C) or type N (-200 … 1300 °C). The range of both channels is freely adjustable in the range -3200.0 … +3200.0.\u003c\/p\u003e\n\u003cp\u003eThe output provides \u003cstrong\u003eIO-Link\u003c\/strong\u003e with level 0 \/ 24 V \u003cstrong\u003eand\u003c\/strong\u003e a current output \u003cstrong\u003e4 … 20 mA\u003c\/strong\u003e, which runs via input 1. The resolution is 16 bit on the strain gauge channel and 24 bit on the universal channel, with an accuracy of max. 0.05 % of the measuring range plus sensor error. Filter: 0.5 s for strain gauge, 25 s for temperature. Supply \u003cstrong\u003e24 VDC\u003c\/strong\u003e at under 30 mA in standard operation, maximum 130 mA total current.\u003c\/p\u003e\n\u003cp\u003eThe board measures \u003cstrong\u003e21 × 76.95 × 4.2 mm\u003c\/strong\u003e and weighs approximately 7.6 g, material FR4 and PBT, connection via solder pads 2.7 × 1.5 mm, mounting position optional, operating range \u003cstrong\u003e-20 °C to +80 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThree mounting requirements and the enabling of the limit values must be read before the housing is closed.\u003c\/strong\u003e The board must be installed in the sensor housing to at least \u003cstrong\u003eIP54\u003c\/strong\u003e and protected against vibrations; the safety circuit must be regularly checked for function, the manufacturer recommends \u003cstrong\u003etwo years\u003c\/strong\u003e, and the limit values must be checked before commissioning. To set the limit values via IO-Link, a \u003cstrong\u003ephototransistor\u003c\/strong\u003e (SFH 309 or similar) must be connected and illuminated; thereafter, the settings must be read back and the phototransistor darkened – in normal operation, it must be covered in such a way that unintentional illumination is excluded.\u003c\/p\u003e\n\u003cp\u003eAn \u003cstrong\u003eIO-Link master\u003c\/strong\u003e is required for configuration and operation, as well as the IODD file from the IODD finder. The board has been tested according to EN 61000-6-2:2005 and EN 61000-6-4:2007. A CE mark is not documented in the manufacturer's data sheet; a declaration of conformity must be requested before placing on the market in the EU. The version without safety function is the \u003cstrong\u003eEOME\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRegarding price:\u003c\/strong\u003e The price applies to the basic version of the board. Measuring ranges and limit values are adjustable via IO-Link, so factory programming is not required. If you would like the board \u003cstrong\u003efactory-programmed to your measuring ranges and switching points\u003c\/strong\u003e, this is possible at an additional cost — \u003ca href=\"\/en\/pages\/contact\"\u003eplease ask us\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eOverload circuit PL c \/ SIL 1, TÜV Nord 44 799 14098202\u003c\/li\u003e\n\n\u003cli\u003eSafety circuit with its own amplifier, parallel to the measuring chain\u003c\/li\u003e\n\n\u003cli\u003eRelay also opens in case of cable break and undervoltage – safe state is open\u003c\/li\u003e\n\n\u003cli\u003eTwo limit values adjustable via IO-Link, reaction time max. 10 ms\u003c\/li\u003e\n\n\u003cli\u003eOutputs IO-Link and 4 … 20 mA\u003c\/li\u003e\n\n\u003cli\u003eChannel 1 full strain gauge bridge, Channel 2 Pt100 or thermocouple\u003c\/li\u003e\n\n\u003cli\u003eResolution 16 bit strain gauge, 24 bit universal, accuracy max. 0.05 %\u003c\/li\u003e\n\n\u003cli\u003e21 × 76.95 × 4.2 mm, approx. 7.6 g, operating range -20 … +80 °C\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57306259620166,"sku":null,"price":369.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/EOMF_MEUTS-SIL_titelbild_b1ff3cac-f6c1-4f9f-be9f-e3eea90af3e2.webp?v=1788951931"},{"product_id":"tsmb-anlegesensor-gefedert-io-link","title":"TSMB spring-loaded surface sensor with IO-Link","description":"\u003cp\u003eThe \u003cstrong\u003eTSMB\u003c\/strong\u003e is a contact sensor with a spring-loaded measuring tip and an IO-Link interface, manufacturer type Müller \u003cstrong\u003eMKTS-SPIO\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIt measures on the surface and in bearings: The compression spring holds the measuring tip with a \u003cstrong\u003e14 mm travel (±1 mm)\u003c\/strong\u003e at the measuring point, even if the component moves or expands due to heat – a rigidly screwed-in sensor would lose contact in such a situation. The sensor tube measures \u003cstrong\u003eØ 6 mm\u003c\/strong\u003e made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, the compression spring is made of spring steel \u003cstrong\u003e1.4310\u003c\/strong\u003e, the protection class is \u003cstrong\u003eIP 65 \/ IP 68\u003c\/strong\u003e, the installation length is \u003cstrong\u003e45 or 65 mm\u003c\/strong\u003e, the weight is approximately \u003cstrong\u003e200 g\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eThe mechanics are the same as with the \u003cstrong\u003eTSMA\u003c\/strong\u003e (MKTS-SP); instead of a HART transmitter, an IO-Link transmitter is installed here. The measured value is sent digitally to the \u003cstrong\u003eIO-Link\u003c\/strong\u003e master, and the sensor is also parameterized there – a configuration device is not necessary, the description of the values is in the device file \u003cstrong\u003eIODD MKTS-SPIO\u003c\/strong\u003e. The electrical connection is \u003cstrong\u003eM12x1 four-pin\u003c\/strong\u003e as the only option; the sensor does not have a display or limit contacts.\u003c\/p\u003e\u003cp\u003eThe input has \u003cstrong\u003ea Pt100\u003c\/strong\u003e in a \u003cstrong\u003e3-wire circuit\u003c\/strong\u003e or a thermocouple \u003cstrong\u003eType J, K or N\u003c\/strong\u003e. The nominal range extends from \u003cstrong\u003e-50 … +150 °C\u003c\/strong\u003e in all versions; a measuring range of \u003cstrong\u003e0 … 100 °C\u003c\/strong\u003e is set ex works, customizable. The source states the accuracy as \u003cstrong\u003emax. 0.02 % of the range\u003c\/strong\u003e plus sensor error at \u003cstrong\u003e16 Bit\u003c\/strong\u003e and \u003cstrong\u003e20 ms\u003c\/strong\u003e response time, powered by \u003cstrong\u003e24 VDC\u003c\/strong\u003e with reverse polarity protection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e This sensor does not withstand process pressure. The source explicitly states: System pressure not possible, the process connection has no sealing effect; the Pressure Equipment Directive is therefore not applicable. The ambient temperature is not the medium temperature: The electronics in the head tolerate \u003cstrong\u003e-20 … +80 °C\u003c\/strong\u003e, the medium up to +150 °C; the source does not state what neck length or insulation is required for this. The accuracy specification is remarkably favorable: 0.02 % of the range at 16 Bit, while the sister sheets with 24 Bit only guarantee 0.1 % and the MKTS-SP with the same design states 0.3 % – before designing, the value must be confirmed with the manufacturer, the sensor error is always added. The relationship between filter and response time is also striking: 25 s filter at 20 ms response time. The datasheet does not specify a minimum span. A CE mark is not documented, a declaration of conformity is not available; explosion protection is also not documented.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eSpring-loaded measuring tip, travel 14 mm ±1 mm\u003c\/li\u003e\n\n\u003cli\u003eIO-Link with signal level 0\/24 V, parameterization via the master\u003c\/li\u003e\n\n\u003cli\u003eRange -50 to +150 °C, factory setting 0 … 100 °C\u003c\/li\u003e\n\n\u003cli\u003eInstallation length 45 or 65 mm, sensor tube Ø 6 mm made of 1.4571\u003c\/li\u003e\n\n\u003cli\u003eVersion with HART available as TSMA\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356932645190,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TSMB_produkt_1b00777b-4c87-4666-b6a6-cf34fa5127d4.webp?v=1789243718"},{"product_id":"temh-kompakt-temperatursensor-mit-io-link","title":"TEMH compact temperature sensor with IO-Link","description":"\u003cp\u003eThe \u003cstrong\u003eTEMH\u003c\/strong\u003e is a compact temperature sensor with an IO-Link interface, manufacturer type Müller \u003cstrong\u003eMKTS-IO\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIt measures where the temperature is taken directly in the medium – in pipelines, tanks, hydraulic and cooling circuits. The sensor tube Ø 6 mm and housing are made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, the electronics are potted (\u003cstrong\u003eIP 65 \/ IP 68\u003c\/strong\u003e), and the system pressure is \u003cstrong\u003emax. 25 bar\u003c\/strong\u003e. The insertion length ranges from 50 to 1000 mm, and the mounting position is arbitrary.\u003c\/p\u003e\u003cp\u003eThe benefit lies in its digital integration: the measured value is sent via \u003cstrong\u003eIO-Link\u003c\/strong\u003e to the master, where the sensor is also parameterized – without a configuration device and without analog wiring; the settable values are described in the device file \u003cstrong\u003eIODD MKTS\u003c\/strong\u003e. As the only one in the series, it also accommodates \u003cstrong\u003etype J, K, and N thermocouples\u003c\/strong\u003e, thereby covering measurement points with existing thermocouple wiring. Electrically, there is exactly one connection, \u003cstrong\u003eM12x1 four-pin\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eThe input contains \u003cstrong\u003ea Pt100\u003c\/strong\u003e in a \u003cstrong\u003e3-wire circuit\u003c\/strong\u003e in classes A, B, and AA, class C on request, or alternatively a thermocouple. The nominal range for all elements is from \u003cstrong\u003e-50 … +200 °C\u003c\/strong\u003e. The source states the accuracy as \u003cstrong\u003emax. 0.02 % of the range\u003c\/strong\u003e plus sensor error at \u003cstrong\u003e16 bit\u003c\/strong\u003e and \u003cstrong\u003e20 ms\u003c\/strong\u003e response time; the sensor is powered with \u003cstrong\u003e24 VDC\u003c\/strong\u003e with reverse polarity protection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The ambient temperature is not the medium temperature – the medium may be up to +200 °C, but the electronics in the head only tolerate -20 … +80 °C; the source does not state what neck length or insulation is required for this. The accuracy specification contradicts the sister sheets: here, 0.02 % of the range is stated for 16-bit resolution, while the 24-bit versions only guarantee 0.1 % – the better value is on the coarser converter, which needs to be confirmed with the manufacturer before design. Filters and response time also do not match: 25 s filter at 20 ms response time, without explanation in the source. The product identification is not unambiguously documented: the order key has a placeholder in the second position, the product overview lists MX – please specify the type designation in plain text. A CE mark is not documented, and a declaration of conformity is not available; regarding the IO-Link interface, the source names the specification but no version number or test certificate. Explosion protection is not documented.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eIO-Link interface with signal level 0\/24 V, parameterization via the master\u003c\/li\u003e\n\n\u003cli\u003eAs the only one in the series, also type J, K, and N thermocouples\u003c\/li\u003e\n\n\u003cli\u003ePt100 3-wire in classes A, B, and AA\u003c\/li\u003e\n\n\u003cli\u003eNominal range -50 to +200 °C for each element\u003c\/li\u003e\n\n\u003cli\u003eA single M12x1 four-pin connection, no variety of connectors\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356933890374,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TPME_produkt_41cde47e-8c9e-4325-98c9-99709e30d2df.webp?v=1789243718"},{"product_id":"qtkd-turbinen-durchflussmesser-mit-temperaturmessung","title":"QTKD turbine flow and temperature sensor","description":"\u003cp\u003eThe \u003cstrong\u003eQTKD\u003c\/strong\u003e is a turbine flowmeter with integrated temperature measurement for nominal sizes from DN 6 to DN 50. It is particularly suited to oil or water where flow and temperature are to be displayed, monitored and output together.\u003c\/p\u003e\u003cp\u003eTurbine principle, measuring range \u003cstrong\u003e0.7 … 660 L\/min\u003c\/strong\u003e (DN 6 … DN 50), accuracy \u003cstrong\u003e≤ ±1.0 % linear\u003c\/strong\u003e, switching and analog accuracy each ≤ ±0.5 % of the range, calibrated with lubricating oil 46# at 25 °C. Outputs: switch PNP or NPN, \u003cstrong\u003eIO-Link\u003c\/strong\u003e, \u003cstrong\u003eRS485\u003c\/strong\u003e, analog \u003cstrong\u003e4 … 20 mA, 1 … 5 V or 0 … 10 V\u003c\/strong\u003e for flow and temperature, pulse and frequency; switching load \u0026lt; 200 mA. Supply \u003cstrong\u003e16 … 30 V DC\u003c\/strong\u003e, connection \u003cstrong\u003eM12 × 1\u003c\/strong\u003e, 5-pin or 4-pin with RS485. Response time 0.1 … 5.0 s, settable.\u003c\/p\u003e\u003cp\u003eShell of stainless steel 304L or, by order code, in the 'alumina' version, turbine rotor of duplex steel, sliding bearing, display head of engineering plastics. Pressure rating 400 bar in the internal thread version, process connection G 1\/2\" … 2\". Medium temperature -20 … +80 °C, -30 … +180 °C in the split high-temperature version; ambient -20 … +75 °C; protection \u003cstrong\u003eIP67\u003c\/strong\u003e. A declaration of conformity is not documented in the datasheet. Before sizing, note: the analog output starts at 0 L\/min, not at the start of the measuring range. In the RS485 version OUT3 is omitted and the connector is 4-pin.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eFlow and temperature on one colour display\u003c\/li\u003e\u003cli\u003eAccuracy ≤ ±1.0 % linear\u003c\/li\u003e\u003cli\u003eAnalog 4 … 20 mA, 1 … 5 V or 0 … 10 V per variable\u003c\/li\u003e\u003cli\u003eIO-Link or RS485\u003c\/li\u003e\u003cli\u003ePressure rating 400 bar\u003c\/li\u003e\u003cli\u003eAll parameters set with three keys\u003c\/li\u003e\u003cli\u003eTwo signal lamps for the switching outputs\u003c\/li\u003e\u003cli\u003eHigh-temperature version up to +180 °C\u003c\/li\u003e\u003cli\u003eProtection IP67\u003c\/li\u003e\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57453638844742,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/QTKD_produkt.webp?v=1790331901"},{"product_id":"qtke-turbinen-durchflussmesser-mit-led-anzeige","title":"QTKE turbine flowmeter with LED display","description":"\u003cp\u003eThe \u003cstrong\u003eQTKE\u003c\/strong\u003e is an electronic turbine flowmeter with a four-digit LED display for nominal sizes from DN 10 to DN 300. It is particularly suited to oil or water with medium temperatures up to +120 °C where, in version A2, the temperature is to be output alongside the flow.\u003c\/p\u003e\u003cp\u003eTurbine principle, measuring range \u003cstrong\u003eDN 10 … DN 300\u003c\/strong\u003e with flow rates of \u003cstrong\u003e0.06 … 1800 m³\/h\u003c\/strong\u003e, accuracy \u003cstrong\u003e≤ ±1.0 % of the range\u003c\/strong\u003e, switching and analog accuracy each ≤ ±0.5 % of the range, response time 0.1 … 5 s. Flow outputs: switch, analog and pulse, \u003cstrong\u003eIO-Link\u003c\/strong\u003e, \u003cstrong\u003eRS485\u003c\/strong\u003e; temperature: switch, analog and RS485 with code A2 only. Supply \u003cstrong\u003e12 … 30 V DC\u003c\/strong\u003e, power consumption \u0026lt; 60 mA, switch load \u0026lt; 200 mA at 24 V DC, connection \u003cstrong\u003eM12 × 1\u003c\/strong\u003e. Display range 0.000 … 9999.\u003c\/p\u003e\u003cp\u003eHousing of stainless steel 304, display head of engineering plastic, turbine rotor of duplex steel, bearing of graphite up to DN32 and tungsten steel from DN40. Nominal pressure PN 6.3 · 16 · 25 · 40 MPa up to DN32, 2.5 MPa up to DN100, 1.6 MPa up to DN300; max. pressure loss 0.05 MPa at DN10 down to 0.025 MPa up to DN300. Medium temperature -30 … +120 °C, high-temperature type on request; ambient -20 … +80 °C; protection \u003cstrong\u003eIP67\u003c\/strong\u003e. A declaration of conformity is not documented in the datasheet. Before sizing, note: the coil-type minimum flows at DN12 and DN15 run backwards and have to be settled with the enquiry. The maximum flow of 222 m³\/h at DN100 breaks the series and also has to be settled with the enquiry.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eFour-digit LED display\u003c\/li\u003e\u003cli\u003eAccuracy ≤ ±1.0 % of the range\u003c\/li\u003e\u003cli\u003eIO-Link and RS485\u003c\/li\u003e\u003cli\u003eTemperature output in version A2\u003c\/li\u003e\u003cli\u003eMedium temperature up to +120 °C\u003c\/li\u003e\u003cli\u003eBearing of graphite or tungsten steel by size\u003c\/li\u003e\u003cli\u003eReverse polarity, overload and short-circuit protection\u003c\/li\u003e\u003cli\u003eProtection IP67\u003c\/li\u003e\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57453638877510,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/QTKE_produkt.webp?v=1790331901"},{"product_id":"qzka-zahnrad-durchflussmesser-mit-farbdisplay","title":"QZKA gear flowmeter with colour display","description":"\u003cp\u003eThe \u003cstrong\u003eQZKA\u003c\/strong\u003e is a positive displacement gear flowmeter for small and viscous flows. It is particularly suited to oils, fats, fuels, resins, adhesives, solvents, inks and refrigerants up to a viscosity of 10 000 Pa·s.\u003c\/p\u003e\u003cp\u003eTwo meshing gears displace a fixed volume per revolution, measuring range \u003cstrong\u003e5 mL\/min … 150 L\/min\u003c\/strong\u003e in seven sizes, accuracy \u003cstrong\u003e± 0.5 % of full scale\u003c\/strong\u003e, repeatability \u003cstrong\u003e± 0.2 % of full scale\u003c\/strong\u003e. Version A3: two switches PNP\/NPN and analog \u003cstrong\u003e4 … 20 mA, 1 … 5 V or 0 … 10 V\u003c\/strong\u003e; AR: \u003cstrong\u003eRS485\u003c\/strong\u003e plus analog; SA: analog for flow and temperature, switch, pulse and \u003cstrong\u003eIO-Link\u003c\/strong\u003e. Supply \u003cstrong\u003e12 … 30 V DC\u003c\/strong\u003e, plug \u003cstrong\u003eM12 × 1\u003c\/strong\u003e, five-pin. Colour display with flow, percentage of range and totalized volume, three keys.\u003c\/p\u003e\u003cp\u003eBody of aluminium (40 bar), stainless steel 304 or 316 (100 · 250 · 400 bar) or PP (10 bar); seal FKM up to 200 bar, PTFE above 200 bar or EPDM. Process connection G1\/4 … G1 by size, two mounting threads M5, M6 or M8. Medium temperature -30 … +120 °C, +140 °C with code T (not for aluminium and PP). The protection grade is not documented and the sheet names no CE mark. A declaration of conformity is not documented in the datasheet. Before sizing, note: the pressure statements disagree, and FKM stops at 200 bar although 250 and 400 bar bodies are offered. The accuracy refers to full scale, not to the reading. A filter finer than 100 mesh is required ahead of the meter.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\u003cli\u003ePositive displacement, reading independent of density and viscosity\u003c\/li\u003e\u003cli\u003eSeven sizes from 5 mL\/min to 150 L\/min\u003c\/li\u003e\u003cli\u003eRepeatability ± 0.2 % of full scale\u003c\/li\u003e\u003cli\u003eOutputs 4 … 20 mA, PNP\/NPN, pulse, RS485, IO-Link\u003c\/li\u003e\u003cli\u003eColour display with totalizer and three keys\u003c\/li\u003e\u003cli\u003eStainless steel body up to 400 bar\u003c\/li\u003e\u003cli\u003eHigh-temperature option up to +140 °C\u003c\/li\u003e\u003cli\u003eTemperature output in version SA\u003c\/li\u003e\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57453638910278,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/QZKA_produkt.webp?v=1790331901"},{"product_id":"qzkb-zahnrad-durchflussmesser-fur-plattenmontage","title":"QZKB plate-mounted gear flowmeter","description":"\u003cp\u003eThe \u003cstrong\u003eQZKB\u003c\/strong\u003e is a gear flowmeter for mounting on a machined plate instead of in a pipe. It is particularly suited to additive fuels, corrosion inhibitors, catalysts, emulsifiers, oils, fats, fragrances, adhesives, solvents, inks and insecticides in systems up to 400 bar.\u003c\/p\u003e\u003cp\u003ePositive displacement with two meshing gears, no straight inlet run needed. Measuring range \u003cstrong\u003e50 mL\/min … 350 L\/min\u003c\/strong\u003e in seven steps, accuracy \u003cstrong\u003e± 0.5 % of full scale\u003c\/strong\u003e, repeatability \u003cstrong\u003e± 0.2 % of full scale\u003c\/strong\u003e. Output A3: two switches PNP or NPN or pulse, OUT3 \u003cstrong\u003e4 … 20 mA, 1 … 5 V or 0 … 10 V\u003c\/strong\u003e; AR: \u003cstrong\u003eRS485\u003c\/strong\u003e plus analog; SA: flow or temperature as switch, pulse, analog or \u003cstrong\u003eIO-Link\u003c\/strong\u003e. Supply \u003cstrong\u003e16 … 30 V DC\u003c\/strong\u003e, plug \u003cstrong\u003eM12 × 1\u003c\/strong\u003e, five-pin. Colour display with instantaneous flow, totalized volume and raw frequency, three keys.\u003c\/p\u003e\u003cp\u003eHousing of stainless steel (grade not named), display housing of stainless steel or engineering plastic, seal FKM. Pressure \u003cstrong\u003e400 bar\u003c\/strong\u003e. Medium temperature -30 … +120 °C, +140 °C with field T of the order code. Plate mounting with two sealing grooves; the 350 L\/min size has a SAE 1¼ inch 6000 PSI flange face. The protection grade is not documented. A declaration of conformity is not documented in the datasheet. Before sizing, note: the supply is given as 16 … 30 V DC in the data block and 12 … 30 V DC in the wiring diagram; design for 16 … 30 V DC until clarified. Without a stated K-factor the pulse output cannot be scaled. The mounting plate is drawn for only four of the seven ranges.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\u003cli\u003ePlate mounting without straight inlet run\u003c\/li\u003e\u003cli\u003ePressure up to 400 bar\u003c\/li\u003e\u003cli\u003eSeven ranges from 50 mL\/min to 350 L\/min\u003c\/li\u003e\u003cli\u003eRepeatability ± 0.2 % of full scale\u003c\/li\u003e\u003cli\u003eOutputs 4 … 20 mA, PNP\/NPN, pulse, RS485 or IO-Link\u003c\/li\u003e\u003cli\u003eTemperature output in version SA\u003c\/li\u003e\u003cli\u003eColour display with totalizer and frequency page\u003c\/li\u003e\u003cli\u003eAccuracy stated as unaffected by pressure and flow changes\u003c\/li\u003e\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57453640909126,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/QZKB_produkt.webp?v=1790331901"},{"product_id":"qfkb-flugelrad-durchflussmesser-mit-farbdisplay","title":"QFKB impeller flowmeter with colour display","description":"\u003cp\u003eThe \u003cstrong\u003eQFKB\u003c\/strong\u003e is an impeller flowmeter with a display head and colour display for nominal sizes from DN10 to DN32. It is particularly suited to applications where flow and temperature are to be read at the device and transmitted via IO-Link or RS485.\u003c\/p\u003e\u003cp\u003eImpeller principle, flow velocity \u003cstrong\u003e0.15 … 6 m\/s\u003c\/strong\u003e, flow rate \u003cstrong\u003e3 … 250 L\/min\u003c\/strong\u003e by size, linear accuracy \u003cstrong\u003e± 1.0 % F.S.\u003c\/strong\u003e, repeatability ± 5 % F.S., temperature 0 … 100 °C with ± 1.5 °C. Outputs: switch PNP or NPN for flow and temperature, analog \u003cstrong\u003e4 … 20 mA, 1 … 5 V or 0 … 10 V\u003c\/strong\u003e, pulse, \u003cstrong\u003eIO-Link\u003c\/strong\u003e and \u003cstrong\u003eRS485\u003c\/strong\u003e. Supply \u003cstrong\u003e12 … 30 V DC\u003c\/strong\u003e, connection \u003cstrong\u003eM12 × 1\u003c\/strong\u003e, 5-pin. The colour display shows instantaneous flow, percentage of range and totalized flow and can be turned by 180°.\u003c\/p\u003e\u003cp\u003eHead of stainless steel with plastic display window, body of POM, aluminium or stainless steel, O-ring FPM or EPDM, impeller of PP, bearing and shaft of ZrO2 ceramic, titanium alloy or Hastelloy C. Pressure POM 14 bar at 25 °C and 1.7 bar at 100 °C, aluminium 25 bar. Process connection G or Rc thread, internal or external, 1\/2\" … 1-1\/4\". Medium temperature 0 … 100 °C, protection \u003cstrong\u003eIP67\u003c\/strong\u003e. A declaration of conformity is not documented in the datasheet. Before sizing, note: the technical data give DC 5 … 24 V, the wiring diagram 12 … 30 V DC. No pressure is documented for the stainless steel body. IO-Link lacks version and IODD, RS485 lacks protocol, baud rate and register map.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eColour display, turnable by 180°\u003c\/li\u003e\u003cli\u003eIO-Link and RS485\u003c\/li\u003e\u003cli\u003eAnalog 4 … 20 mA, 1 … 5 V or 0 … 10 V\u003c\/li\u003e\u003cli\u003eFlow and temperature as switch or analog signal\u003c\/li\u003e\u003cli\u003eTotalized flow and original frequency on the second page\u003c\/li\u003e\u003cli\u003eOperation with three keys\u003c\/li\u003e\u003cli\u003eBody of POM, aluminium or stainless steel\u003c\/li\u003e\u003cli\u003eProtection IP67\u003c\/li\u003e\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57453644710214,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/QFKB_produkt.webp?v=1790331840"},{"product_id":"qfke-flugelrad-einstecksensor","title":"QFKE insertion impeller flow sensor","description":"\u003cp\u003eThe \u003cstrong\u003eQFKE\u003c\/strong\u003e is an insertion impeller flow sensor that is fitted into the pipe through a welding socket. It is particularly suited to pipes from DN25 to DN600, since one device covers all these sizes and no size has to be chosen.\u003c\/p\u003e\u003cp\u003eImpeller principle, the measured quantity is the \u003cstrong\u003eflow velocity 0.15 … 6 m\/s\u003c\/strong\u003e; no volume flow table is given. Linear accuracy \u003cstrong\u003e± 1.0 % F.S.\u003c\/strong\u003e, repeatability ± 5 % F.S., temperature 0 … 100 °C with ± 1.5 °C. Outputs: switch PNP or NPN for flow and temperature, analog \u003cstrong\u003e4 … 20 mA, 1 … 5 V or 0 … 10 V\u003c\/strong\u003e, pulse, \u003cstrong\u003eIO-Link\u003c\/strong\u003e and \u003cstrong\u003eRS485\u003c\/strong\u003e. Supply \u003cstrong\u003e12 … 30 V DC\u003c\/strong\u003e, connection \u003cstrong\u003eM12 × 1\u003c\/strong\u003e, 5-pin. Colour display with instantaneous value, percentage of range and totalized flow, three keys.\u003c\/p\u003e\u003cp\u003eSensor body of stainless steel, O-ring FPM (default) or EPDM, impeller of PP (default) or PVDF, bearing and shaft of ZrO2 ceramic, stainless steel 316L, titanium alloy or Hastelloy. Process connection M32 × 1.5 through a welding socket, pressure \u003cstrong\u003e25 bar\u003c\/strong\u003e, medium temperature 0 … 100 °C, protection \u003cstrong\u003eIP67\u003c\/strong\u003e. Straight pipe run 5 … 10 × DN before and 3 … 5 × DN after the sensor. A declaration of conformity is not documented in the datasheet. Before sizing, note: table and k-factor for converting velocity into volume flow are missing. At ± 5 % FS the repeatability is five times the linearity error; the value has to be settled with the enquiry. No process connection other than the welding socket is documented.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eOne device for DN25 … DN600\u003c\/li\u003e\u003cli\u003eFitted through welding socket M32 × 1.5\u003c\/li\u003e\u003cli\u003eColour display with totalizer\u003c\/li\u003e\u003cli\u003eIO-Link and RS485\u003c\/li\u003e\u003cli\u003eAnalog 4 … 20 mA, 1 … 5 V or 0 … 10 V\u003c\/li\u003e\u003cli\u003eTemperature measurement with ± 1.5 °C\u003c\/li\u003e\u003cli\u003ePressure up to 25 bar, protection IP67\u003c\/li\u003e\u003cli\u003eImpeller optionally of PVDF\u003c\/li\u003e\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57453644775750,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/QFKE_produkt.webp?v=1790331840"},{"product_id":"qekd-stromungs-temperatursensor-farbdisplay-io-link","title":"QEKD flow and temperature sensor, colour display, IO-Link","description":"\u003cp\u003eThe \u003cstrong\u003eQEKD\u003c\/strong\u003e is a thermal flow and temperature sensor with colour display and IO-Link. It is particularly suited to monitoring flow and temperature together in water lines, with one sensor covering a range of pipe diameters.\u003c\/p\u003e\u003cp\u003eSealed probe with a heated detection resistor and an unheated reference resistor. Flow velocity \u003cstrong\u003e0.01 … 2.0 m\/s\u003c\/strong\u003e (water), dead zone ≤ 0.01 m\/s, temperature \u003cstrong\u003e0 … 100 °C\u003c\/strong\u003e with \u003cstrong\u003e± 1.5 °C\u003c\/strong\u003e. Flow accuracy and repeatability are not documented. Switching output PNP or NPN (max. 200 mA) with IO-Link, analogue output \u003cstrong\u003e4 … 20 mA\u003c\/strong\u003e or \u003cstrong\u003e1 … 5 V\u003c\/strong\u003e for flow and temperature, frequency output 100 Hz at full scale. Supply \u003cstrong\u003e24 V DC ± 20 %\u003c\/strong\u003e, connection \u003cstrong\u003eM12 × 1\u003c\/strong\u003e, 5-pin.\u003c\/p\u003e\u003cp\u003eWetted parts stainless steel 316L and EPDM, housing stainless steel, head stainless steel or engineering plastic. Process connection M18 × 1.5 internal thread, probe rod or chuck Ø 25.4 mm or Ø 50.5 mm. Pressure range \u003cstrong\u003e100 bar\u003c\/strong\u003e, medium temperature 0 … 100 °C, ambient -20 … +80 °C, protection grade \u003cstrong\u003eIP67\u003c\/strong\u003e. A declaration of conformity is not documented in the data sheet. Before sizing, note: The flow range is documented for water only, although the documentation names oil and gas as applications. A flow accuracy has to be requested. The technical data give 24 V DC ± 20 %, the wiring diagram 12 … 30 V DC.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eFlow and temperature in one device\u003c\/li\u003e\u003cli\u003eThermal principle without moving parts\u003c\/li\u003e\u003cli\u003e0.96\" colour display for flow and temperature\u003c\/li\u003e\u003cli\u003eIO-Link on the switching output\u003c\/li\u003e\u003cli\u003eTwo signal lamps, one for each switching output\u003c\/li\u003e\u003cli\u003eSetting by the three keys −, M and +\u003c\/li\u003e\u003cli\u003eWetted parts stainless steel 316L and EPDM\u003c\/li\u003e\u003cli\u003ePressure range 100 bar, protection grade IP67\u003c\/li\u003e\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57453657358662,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/QEKD_produkt.webp?v=1790331840"},{"product_id":"qeke-stromungs-temperatursensor-fur-wasser-farbdisplay","title":"QEKE water flow and temperature sensor, colour display","description":"\u003cp\u003eThe \u003cstrong\u003eQEKE\u003c\/strong\u003e is a thermal flow and temperature sensor for water, circulating water and cutting fluid. It is particularly suited as a low flow alarm, for cut-off detection and for pump idling protection.\u003c\/p\u003e\u003cp\u003eSealed probe with a heated detection resistor and an unheated reference resistor. Flow velocity \u003cstrong\u003e0 … 3 m\/s\u003c\/strong\u003e (water), measuring accuracy \u003cstrong\u003e\u0026lt; 10.0 %\u003c\/strong\u003e, dead zone ≤ 0.01 m\/s, temperature \u003cstrong\u003e0 … 100 °C\u003c\/strong\u003e with \u003cstrong\u003e± 1.5 °C\u003c\/strong\u003e. Repeatability is not documented. Switching output PNP or NPN (max. 200 mA) with IO-Link, analogue output \u003cstrong\u003e4 … 20 mA\u003c\/strong\u003e or \u003cstrong\u003e1 … 5 V\u003c\/strong\u003e for flow and temperature, frequency output 200 Hz at full scale. Supply \u003cstrong\u003e24 V DC ± 20 %\u003c\/strong\u003e, connection \u003cstrong\u003eM12 × 1\u003c\/strong\u003e, 5-pin.\u003c\/p\u003e\u003cp\u003eWetted parts stainless steel 316L and EPDM, housing stainless steel, head stainless steel or engineering plastic. Process connection M18 × 1.5 internal thread, probe rod or chuck Ø 25.4 mm or Ø 50.5 mm. Pressure range \u003cstrong\u003e60 bar\u003c\/strong\u003e, medium temperature 0 … 100 °C, ambient -20 … +80 °C, protection grade \u003cstrong\u003eIP67\u003c\/strong\u003e. A declaration of conformity is not documented in the data sheet. Before sizing, note: The accuracy \u0026lt; 10.0 % is given without saying whether it refers to the reading or to the full scale. A repeatability has to be requested. The technical data give 24 V DC ± 20 %, the wiring diagram 12 … 30 V DC.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eFlow and temperature in one device\u003c\/li\u003e\u003cli\u003eThermal principle without moving parts\u003c\/li\u003e\u003cli\u003eConversion table velocity\/volume flow in the data sheet\u003c\/li\u003e\u003cli\u003e0.96\" colour display for flow and temperature\u003c\/li\u003e\u003cli\u003eIO-Link on the switching output\u003c\/li\u003e\u003cli\u003eSetting by the three keys −, M and +\u003c\/li\u003e\u003cli\u003eWetted parts stainless steel 316L and EPDM\u003c\/li\u003e\u003cli\u003ePressure range 60 bar, protection grade IP67\u003c\/li\u003e\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57453657948486,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/QEKE_produkt.webp?v=1790331840"},{"product_id":"qekf-stromungs-temperatursensor-fur-gase-farbdisplay","title":"QEKF gas flow and temperature sensor, colour display","description":"\u003cp\u003eThe \u003cstrong\u003eQEKF\u003c\/strong\u003e is a thermal flow and temperature sensor for air and other gases. It is particularly suited to air flow detection, to gas flow measurement of various kinds and to flow interruption protection.\u003c\/p\u003e\u003cp\u003eSealed probe with a heated detection resistor and an unheated reference resistor. Flow velocity \u003cstrong\u003e0 … 60 m\/s\u003c\/strong\u003e (reference medium air), measuring accuracy \u003cstrong\u003e≤ ± 6 %\u003c\/strong\u003e, dead zone ≤ 0.1 m\/s, temperature \u003cstrong\u003e0 … 100 °C\u003c\/strong\u003e with \u003cstrong\u003e± 1.5 °C\u003c\/strong\u003e. Repeatability is not documented. Switching output PNP or NPN (max. 200 mA) with IO-Link, analogue output \u003cstrong\u003e4 … 20 mA\u003c\/strong\u003e or \u003cstrong\u003e1 … 5 V\u003c\/strong\u003e for flow and temperature, frequency output 200 Hz at full scale. Supply \u003cstrong\u003e24 V DC ± 20 %\u003c\/strong\u003e, connection \u003cstrong\u003eM12 × 1\u003c\/strong\u003e, 5-pin.\u003c\/p\u003e\u003cp\u003eWetted parts stainless steel 316L and EPDM, housing stainless steel, head stainless steel or engineering plastic. Process connection M18 × 1.5 internal thread, probe rod or chuck Ø 25.4 mm or Ø 50.5 mm. Pressure range \u003cstrong\u003e60 bar\u003c\/strong\u003e, medium temperature 0 … 100 °C, ambient -20 … +80 °C, protection grade \u003cstrong\u003eIP67\u003c\/strong\u003e. A declaration of conformity is not documented in the data sheet. Before sizing, note: The accuracy ≤ ± 6 % is given without saying whether it refers to the reading or to the full scale. No conversion from velocity to volume flow is given for gas. The technical data give 24 V DC ± 20 %, the wiring diagram 12 … 30 V DC.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eFlow and temperature in one device\u003c\/li\u003e\u003cli\u003eThermal principle without moving parts\u003c\/li\u003e\u003cli\u003eFor air and other gases\u003c\/li\u003e\u003cli\u003e0.96\" colour display for flow and temperature\u003c\/li\u003e\u003cli\u003eIO-Link on the switching output\u003c\/li\u003e\u003cli\u003eTwo signal lamps, one for each switching output\u003c\/li\u003e\u003cli\u003eWetted parts stainless steel 316L and EPDM\u003c\/li\u003e\u003cli\u003ePressure range 60 bar, protection grade IP67\u003c\/li\u003e\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57453657981254,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/QEKF_produkt.webp?v=1790331840"},{"product_id":"qekg-stromungs-temperatursensor-led-anzeige-io-link","title":"QEKG flow and temperature sensor, LED display, IO-Link","description":"\u003cp\u003eThe \u003cstrong\u003eQEKG\u003c\/strong\u003e is a thermal flow and temperature sensor with four-digit LED display and IO-Link. It is particularly suited to water, ethylene glycol solution, air and oil in pipes up to \u003cstrong\u003e400 mm\u003c\/strong\u003e diameter.\u003c\/p\u003e\u003cp\u003eTwo measuring elements and a heating source on the probe. Flow velocity liquid \u003cstrong\u003e≤ 3 m\/s\u003c\/strong\u003e, gas \u003cstrong\u003e≤ 100 m\/s\u003c\/strong\u003e, temperature \u003cstrong\u003e-20 … +80 °C\u003c\/strong\u003e. Accuracy and repeatability are not documented. Two switching outputs PNP or NPN (S1 flow, S2 temperature, max. 400 mA), analogue output \u003cstrong\u003e0\/4 … 20 mA\u003c\/strong\u003e, \u003cstrong\u003e0\/1 … 5 V\u003c\/strong\u003e or \u003cstrong\u003e0\/1 … 10 V\u003c\/strong\u003e, pulse output 0 … 1000 Hz, \u003cstrong\u003eIO-Link\u003c\/strong\u003e. Supply \u003cstrong\u003e24 V DC ± 20 %\u003c\/strong\u003e, connection M12 × 1, 5-pin, or cable.\u003c\/p\u003e\u003cp\u003eBody and wetted parts stainless steel 304, display head ABS. Process connection G1\/4 or G1\/2 external thread and M18 × 1.5 internal thread. Pressure range \u003cstrong\u003e100 bar\u003c\/strong\u003e, medium and ambient temperature -20 … +80 °C, protection grade \u003cstrong\u003eIP67\u003c\/strong\u003e, weight about 0.4 kg. A declaration of conformity is not documented in the data sheet. Before sizing, note: The flow range is given only as an upper limit per medium; accuracy and repeatability have to be requested. The M18 × 1.5 internal thread requires a mounting accessory. The technical data give 24 V DC ± 20 %, the wiring diagrams 12 … 30 V DC.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eFlow and temperature in one device\u003c\/li\u003e\u003cli\u003eThermal principle without moving parts\u003c\/li\u003e\u003cli\u003ePipe diameters up to 400 mm\u003c\/li\u003e\u003cli\u003eFor water, glycol solution, air and oil\u003c\/li\u003e\u003cli\u003eFour-digit LED display changing between red and green\u003c\/li\u003e\u003cli\u003eIO-Link, analogue and pulse output\u003c\/li\u003e\u003cli\u003eSetting by the two keys S1 and S2\u003c\/li\u003e\u003cli\u003ePressure range 100 bar, protection grade IP67\u003c\/li\u003e\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57453658014022,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/QEKG_produkt.webp?v=1790331840"},{"product_id":"qekj-vortex-durchflusssensor-temperatur-optional","title":"QEKJ vortex flow sensor, optional temperature","description":"\u003cp\u003eThe \u003cstrong\u003eQEKJ\u003c\/strong\u003e is a vortex flow sensor without moving parts with optional temperature measurement. It is particularly suited to cooling and circulating water, organic and inorganic solutions as well as oxygen, nitrogen, ammonia and natural gas in lines with thread connection \u003cstrong\u003eG3\/8 … G2\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eVortex shedding behind a bluff body; according to the sheet the reading is not affected by the static pressure. Flow \u003cstrong\u003e0.5 … 400 L\/min\u003c\/strong\u003e in seven sizes with \u003cstrong\u003e\u0026lt; ± 3.0 % F.S.\u003c\/strong\u003e, repeatability \u0026lt; 2.0 %, 5-point linearization. Temperature (option) \u003cstrong\u003e0 … 100 °C\u003c\/strong\u003e with ≤ 2.0 °C. Outputs \u003cstrong\u003e4 … 20 mA\u003c\/strong\u003e or \u003cstrong\u003e1 … 5 V\u003c\/strong\u003e up to two channels, switching output PNP or NPN (24 V DC \/ 200 mA), pulse up to 1 kHz, \u003cstrong\u003eIO-Link\u003c\/strong\u003e and \u003cstrong\u003eRS485\u003c\/strong\u003e. Supply \u003cstrong\u003e18 … 30 V DC\u003c\/strong\u003e, connection M8 × 1, 4-pin, or cable 2, 5 or 10 m.\u003c\/p\u003e\u003cp\u003eWetted parts PPS below 100 L\/min, PA66 above 100 L\/min and stainless steel 304. Process connection G3\/8 … G2 internal thread, G, R or NPT. Pressure level \u003cstrong\u003e10 bar\u003c\/strong\u003e, maximum 16 bar, medium temperature -20 … +90 °C, ambient -10 … +65 °C. A protection grade is not documented. A declaration of conformity is not documented in the data sheet. Before sizing, note: No protection grade is given in the sheet; it has to be requested. IO-Link is documented without version and without IODD file, RS485 without protocol, baud rate or register map. The temperature range 0 … 100 °C does not match the medium temperature -20 … +90 °C.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eVortex principle without moving parts\u003c\/li\u003e\u003cli\u003eSeven sizes from 0.5 … 4 to 150 … 400 L\/min\u003c\/li\u003e\u003cli\u003eFor liquids and gases\u003c\/li\u003e\u003cli\u003eTemperature measurement as an option\u003c\/li\u003e\u003cli\u003eTotalizer and 5-point linearization\u003c\/li\u003e\u003cli\u003eAnalogue, switching, pulse, IO-Link and RS485\u003c\/li\u003e\u003cli\u003eDisplay optional, screen can be turned by 180°\u003c\/li\u003e\u003cli\u003eBracket in seven sizes\u003c\/li\u003e\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57453661323590,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/QEKJ_produkt.webp?v=1790331840"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/collections\/blog-io-link-waegezelle.webp?v=1789028781","url":"https:\/\/octogon.org\/en\/collections\/io-link-sensors-measurement-electronics.oembed","provider":"octogon GmbH","version":"1.0","type":"link"}