{"title":"Compact Temperature Sensors","description":"","products":[{"product_id":"temf-kompakt-temperatursensor-mit-schiffszulassung","title":"TEMF compact temperature sensor with marine approval","description":"\u003cp\u003eThe \u003cstrong\u003eTEMF\u003c\/strong\u003e is a modular compact temperature sensor with marine approval, manufacturer type Müller \u003cstrong\u003eMKTS-GL\u003c\/strong\u003e; the intrinsically safe version is called \u003cstrong\u003eMKTS-GLEx\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIt measures directly in the medium, where high pressure and a harsh environment come together: \u003cstrong\u003e250 bar\u003c\/strong\u003e system pressure at \u003cstrong\u003e375 bar\u003c\/strong\u003e burst pressure; sensor tube, housing body and connector insert all in stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e – the connector insert included, no plastic –, protection class \u003cstrong\u003eIP 65\u003c\/strong\u003e at the electronics and \u003cstrong\u003eIP 68\u003c\/strong\u003e at the sensor. Added to this the type approvals \u003cstrong\u003eDNV TAA00003GS\u003c\/strong\u003e and \u003cstrong\u003eEU RO MRA0000052\u003c\/strong\u003e, which apply to both versions.\u003c\/p\u003e\u003cp\u003eOne datasheet covers two versions: they differ in the approval and in the operating temperature – and in nothing else. The \u003cstrong\u003eMKTS-GLEx\u003c\/strong\u003e is additionally intrinsically safe, \u003cstrong\u003eII 1 G Ex ia IIC T6..T1 Ga\u003c\/strong\u003e for zones 0, 1 and 2 with gases; the MKTS-GL has \u003cstrong\u003eno explosion protection\u003c\/strong\u003e. The order codes are identical field by field, only the identifier changes from MK to GN.\u003c\/p\u003e\u003cp\u003eMeasurement is made with \u003cstrong\u003eone or two Pt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e in 2-, 3- or 4-wire technology, in \u003cstrong\u003eclass A\u003c\/strong\u003e only, at 24-bit resolution. The measuring range runs from \u003cstrong\u003e-50 … +200 °C\u003c\/strong\u003e, the smallest span is \u003cstrong\u003e50 K\u003c\/strong\u003e. At the output, \u003cstrong\u003e4 … 20 mA\u003c\/strong\u003e, three voltage ranges or the resistance directly at the connector are available.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The accuracy of \u003cstrong\u003emax. 0.1 % of range\u003c\/strong\u003e applies only between 0 and +40 °C; below that, 0.0015 % per kelvin is added, above it 0.019 % – at +80 °C around 0.76 % on top, plus the error of the measuring element. Ambient temperature and medium temperature are two different things: the MKTS-GL works at \u003cstrong\u003e-40 … +85 °C\u003c\/strong\u003e, whereas for the MKTS-GLEx the limit depends on the temperature class and on the output type – current output -40 … +75 °C, voltage output only -40 … +50 °C, passive -50 … +100 °C. The medium temperature of the MKTS-GLEx is likewise tied to the temperature class: \u003cstrong\u003e+425 °C in T1\u003c\/strong\u003e, +275 °C in T2, +180 °C in T3, +115 °C in T4, +80 °C in T5 and \u003cstrong\u003e+65 °C in T6\u003c\/strong\u003e. Measuring range and medium temperature contradict each other in the source – feature list -50 … +200 °C, data table -50 … +425 °C: the transmitter measures only up to +200 °C, the 425 °C concern what the tube withstands; the lower value applies, and it should be confirmed before sizing. Both Ex certificate numbers end in X – \u003cstrong\u003eTÜV 21 ATEX 201293 X\u003c\/strong\u003e and \u003cstrong\u003eIECEx TUN 21.0005X\u003c\/strong\u003e – and carry special conditions; the source names heat flowing back, impact and friction as well as electrostatic charging. For none of the four certificates do we hold a document, only the numbers are substantiated; a \u003cstrong\u003eCE mark is not documented\u003c\/strong\u003e. The identifier is used more than once – MK for MKTS, MKTS-GL and MKTS-SP, GN for MKTS-Ex and MKTS-GLEx – which is why the type designation belongs in the order in plain text. Two measuring elements are available only without a transmitter; the insertion length (10 … 300 mm in 5 mm steps) must be stated. Configuration is done with the \u003cstrong\u003eDEV-KMA\u003c\/strong\u003e and the TrComm software.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMarine approval DNV TAA00003GS and EU RO MRA0000052, both versions\u003c\/li\u003e\n\u003cli\u003eMKTS-GLEx additionally Ex ia IIC T6..T1 Ga for zones 0, 1 and 2 with gases\u003c\/li\u003e\n\u003cli\u003eSystem pressure 250 bar, burst pressure 375 bar\u003c\/li\u003e\n\u003cli\u003eStainless steel 1.4571 right into the connector insert, IP 65 \/ IP 68\u003c\/li\u003e\n\u003cli\u003ePt100 or Pt1000 in class A, 24-bit resolution\u003c\/li\u003e\n\u003cli\u003e4 … 20 mA, voltage or resistance directly at the connector\u003c\/li\u003e\n\u003cli\u003eMedium temperature up to +425 °C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57041754194246,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TEMF_produkt_c693e71c-2fdd-414d-ac46-12cf9d85c283.webp?v=1789734344"},{"product_id":"tcmc-widerstandsthermometer-kabelfuehler","title":"TCMC resistance thermometer cable probe","description":"\u003cp\u003eThe \u003cstrong\u003eTCMC\u003c\/strong\u003e is a resistance thermometer cable probe, manufacturer type Müller \u003cstrong\u003eWT-K1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt measures at measuring points where there is no space for a connection head: a rigid protective tube, pressed firmly at the transition, and a fixed cable directly leading to evaluation. There is no terminal compartment and no electronics – the probe is inserted into a bore, a compression fitting, or a flange. The protective tube is made of \u003cstrong\u003e1.4571\u003c\/strong\u003e (316Ti) and is approved up to \u003cstrong\u003e600 °C\u003c\/strong\u003e, with \u003cstrong\u003eØ 4, 5, or 6 mm\u003c\/strong\u003e and a wall thickness of \u003cstrong\u003e0.25 … 1 mm\u003c\/strong\u003e; the nominal lengths are \u003cstrong\u003e30, 46, 50, and 70 mm\u003c\/strong\u003e, the maximum length \u003cstrong\u003e2000 mm\u003c\/strong\u003e. The protection class is \u003cstrong\u003eIP 65 up to 250 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe transition to the cable is pressed; a heat shrink tube serves as bend protection, optionally a spring or a crimped transition. The standard cable length is \u003cstrong\u003e2 m\u003c\/strong\u003e. The response time at 6×0.5 mm is \u003cstrong\u003et90 30.9 s\u003c\/strong\u003e, at 6×1 mm \u003cstrong\u003et90 22.1 s\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eA \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, single or double, in \u003cstrong\u003e2-, 3- or 4-wire circuit\u003c\/strong\u003e and without insulating material, serves as the measuring element. The sensor's operating range extends from \u003cstrong\u003e-200 … +450 °C\u003c\/strong\u003e; the accuracy can be ordered in five stages from \u003cstrong\u003eClass A\u003c\/strong\u003e to \u003cstrong\u003eB1\/10DIN\u003c\/strong\u003e. The \u003cstrong\u003eresistance value is immediately available\u003c\/strong\u003e at the output, at open ends of 70 mm; the core colors are shown in the data sheet \u003cstrong\u003eaccording to DIN 60751\u003c\/strong\u003e. A transmitter is not documented. For insulation, the manufacturer only specifies a test voltage of \u003cstrong\u003e500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e The operating range is determined by the cable, not the probe – PVC withstands \u003cstrong\u003e-5 … +70 °C\u003c\/strong\u003e, silicone -45 … +180 °C, PTFE -75 … +205 °C, and glass fiber \u003cstrong\u003e-60 … +550 °C\u003c\/strong\u003e; a sensor up to +450 °C is useless with a PVC cable. The ambient temperature is not the medium temperature – with a cable probe, the cable is in the ambient environment. IP 65 does not apply to the version with braided shielding. The source does not specify a standard for the accuracy classes – if a limit deviation in Kelvin needs to be guaranteed, it must be requested in writing from the manufacturer. In the order key, the digit 3 is missing for the nominal length; digits 0, 1, 2, 4, and 5 are specified; therefore, the length must be clearly stated in the order. Weight, system pressure, CE mark, and explosion protection are not documented. Both versions carry the product identifier \u003cstrong\u003eKW\u003c\/strong\u003e; they are distinguished only by the sensor element position: \u003cstrong\u003e0 … 3\u003c\/strong\u003e is the WT-K1, 4 … 7 is the WT-K1G. The GL version is the \u003cstrong\u003eTCMD\u003c\/strong\u003e (WT-K1G) with the number \u003cstrong\u003eGL TAA00002H5\u003c\/strong\u003e, only with Ø 6 mm and two nominal lengths.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003ePt100 or Pt1000, single or double, -200 … +450 °C\u003c\/li\u003e\n\n\u003cli\u003e2-, 3- or 4-wire circuit, core colors according to DIN 60751\u003c\/li\u003e\n\n\u003cli\u003eProtective tube 1.4571 (316Ti), Ø 4, 5 or 6 mm, up to 600 °C\u003c\/li\u003e\n\n\u003cli\u003eNominal length 30 … 70 mm, up to 2000 mm on request\u003c\/li\u003e\n\n\u003cli\u003eFive cable constructions from PVC to glass fiber, -5 … +550 °C\u003c\/li\u003e\n\n\u003cli\u003eGL version available as TCMD (WT-K1G)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356927009094,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TCMC_produkt_7fc0bea8-e120-475c-84c7-d19caf0513be.webp?v=1789243684"},{"product_id":"tkmc-widerstandsthermometer-mit-anschlusskopf-b","title":"TKMC resistance thermometer with type B connection head","description":"\u003cp\u003eThe \u003cstrong\u003eTKMC\u003c\/strong\u003e is a resistance thermometer with connection head B, manufacturer type Müller \u003cstrong\u003eWT-MR1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is designed for fixed system installation in pipes, tanks, and systems where the measuring point requires a wireable connection. The aluminum \u003cstrong\u003econnection head\u003c\/strong\u003e sits above the process, accommodates a ceramic base with connection posts, and routes the cable out through an \u003cstrong\u003eM20x1.5\u003c\/strong\u003e screw connection; the process connection at the head is \u003cstrong\u003eM24x1.5\u003c\/strong\u003e, and the protection class is \u003cstrong\u003eIP 54\u003c\/strong\u003e. The protective tube made of \u003cstrong\u003e1.4571 (316Ti)\u003c\/strong\u003e or \u003cstrong\u003e2.4816 (Inconel 600)\u003c\/strong\u003e withstands temperatures \u003cstrong\u003eup to 600 °C\u003c\/strong\u003e, with nominal lengths ranging from 50 to 1000 mm and a maximum length of \u003cstrong\u003e2000 mm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eTwo designs cover both mounting types: the screw-in sensor (ES) with process thread on the pipe, and the immersion sensor (ET), which is mounted with accessories; in addition, eleven protection tube diameters from \u003cstrong\u003e3 to 15 mm\u003c\/strong\u003e are available. For the mineral-insulated element, the first approximately \u003cstrong\u003e50 mm\u003c\/strong\u003e from the head are rigid, and the rest is flexible – allowing the sensor to be inserted even without direct access. The manufacturer lists connection cables, compression fittings, and a \u003cstrong\u003etransmitter\u003c\/strong\u003e as accessories.\u003c\/p\u003e\n\u003cp\u003eThe measuring element is a \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, single or double, in \u003cstrong\u003e2-, 3- or 4-wire configuration\u003c\/strong\u003e, as a standard element or as a mineral-insulated element. The sensor's operating range is \u003cstrong\u003e-200 ... +450 °C\u003c\/strong\u003e, with accuracy ranging in five steps from \u003cstrong\u003eClass A to B1\/10DIN\u003c\/strong\u003e. The resistance is located on the ceramic base in the head, and the test voltage is \u003cstrong\u003e500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The ambient temperature is not the medium temperature – the head is limited to \u003cstrong\u003e480 °C\u003c\/strong\u003e, and the element ends at \u003cstrong\u003e450 °C\u003c\/strong\u003e. The source does not specify a standard for the accuracy classes; those who need figures for the limit deviation should request them from the manufacturer. \u003cstrong\u003eIP 54 applies only to the connection head\u003c\/strong\u003e; the source does not specify a protection class for the protective tube. For the mineral-insulated element, the English version additionally mentions 1.5 mm, but the order key does not offer a digit for this – here, \u003cstrong\u003e3, 4.5, and 6 mm\u003c\/strong\u003e apply. The source does not specify the type, output signal, or supply for the transmitter, and a terminal assignment is missing. Weight, system pressure, CE mark, and explosion protection are not documented, and it does not have type approval. The GL version is the \u003cstrong\u003eTKMD\u003c\/strong\u003e (WT-MR1G, TAA00002H5); both carry the product identifier \u003cstrong\u003eKD\u003c\/strong\u003e, differing only in the first digit – 0 ... 3 for TKMC, 4 ... 7 for TKMD.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a Glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003ePt100 or Pt1000, single or double, 2-, 3- or 4-wire configuration\u003c\/li\u003e\n\n\u003cli\u003eOperating range -200 ... +450 °C, five classes from Class A to B1\/10DIN\u003c\/li\u003e\n\n\u003cli\u003eConnection head B made of aluminum, IP 54, cable gland M20x1.5\u003c\/li\u003e\n\n\u003cli\u003eProtective tube 1.4571 or 2.4816, Ø 3 to 15 mm, up to 600 °C\u003c\/li\u003e\n\n\u003cli\u003eInsertion lengths 50 to 1000 mm, maximum 2000 mm\u003c\/li\u003e\n\n\u003cli\u003eGL version TAA00002H5 available as TKMD\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356927107398,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TKMC_produkt_7675337e-980b-4223-a5fe-1801b825aa0d.webp?v=1789243716"},{"product_id":"tcmd-widerstandsthermometer-kabelfuehler-gl","title":"TCMD resistance thermometer cable probe, GL","description":"\u003cp\u003eThe \u003cstrong\u003eTCMD\u003c\/strong\u003e is a resistance thermometer cable sensor with GL type approval, manufacturer type Müller \u003cstrong\u003eWT-K1G\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is the approved version of the cable sensor for measuring points where there is no space for a connection head: rigid protective tube, press-fitted transition, fixed cable for evaluation, no terminal compartment, and no electronics. Compared to the \u003cstrong\u003eWT-K1\u003c\/strong\u003e, the selection is limited – it is \u003cstrong\u003eonly available with Ø 6 mm\u003c\/strong\u003e and in nominal lengths of \u003cstrong\u003e46 or 70 mm\u003c\/strong\u003e, limited to \u003cstrong\u003e200 mm\u003c\/strong\u003e, and the cable to \u003cstrong\u003e6 m\u003c\/strong\u003e. The protective tube is made of \u003cstrong\u003e1.4571\u003c\/strong\u003e (316Ti) and is approved for up to \u003cstrong\u003e600 °C\u003c\/strong\u003e; the protection class is \u003cstrong\u003eIP 65 up to 250 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe transition to the cable is pressed, and a heat shrink tube, optionally a spring, serves as bend protection. Five cable constructions from PVC to glass silk are available, standard length \u003cstrong\u003e2 m\u003c\/strong\u003e. The response time is \u003cstrong\u003et90 30.9 s\u003c\/strong\u003e for 6x0.5 mm and \u003cstrong\u003et90 22.1 s\u003c\/strong\u003e for 6x1 mm.\u003c\/p\u003e\n\u003cp\u003eA \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, single or double, is used as the measuring element, in a \u003cstrong\u003e2-, 3- or 4-wire circuit\u003c\/strong\u003e and without insulation material. The sensor's operating range extends from \u003cstrong\u003e-200 ... +450 °C\u003c\/strong\u003e, and the accuracy can be ordered in five grades from \u003cstrong\u003eClass A\u003c\/strong\u003e to \u003cstrong\u003eB1\/10DIN\u003c\/strong\u003e. The \u003cstrong\u003eresistance value is available immediately\u003c\/strong\u003e at the output, with ferrule on open ends of 70 mm; a transmitter is not documented. The insulation is tested with \u003cstrong\u003e500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The approval \u003cstrong\u003eGL TAA00002H5\u003c\/strong\u003e is documented as a mark and number, not as a certificate; the certificate must be requested before making an assurance to the classification society. Both versions bear the product identification \u003cstrong\u003eKW\u003c\/strong\u003e; they are differentiated solely by the sensor element position: \u003cstrong\u003e4 ... 7\u003c\/strong\u003e is the WT-K1G, 0 ... 3 is the WT-K1. Terminal assignment is not documented for this version – unlike the TCMC, which shows the colors according to DIN 60751; the assignment should be measured before connecting. The operating range is determined by the cable, not the sensor: PVC withstands -5 ... +70 °C, silicone -45 ... +180 °C, PTFE -75 ... +205 °C, glass silk -60 ... +550 °C. The ambient temperature is not the medium temperature, and for cable sensors, the cable is in the ambient environment. IP 65 does not apply to the shielded braid version. The source does not specify a standard for the accuracy classes; wall thickness, weight, system pressure, CE mark, and explosion protection are not documented. The version without GL approval is the \u003cstrong\u003eTCMC\u003c\/strong\u003e (WT-K1), with three diameters and up to 2000 mm.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eGL type approval TAA00002H5 documented in manufacturer sheet\u003c\/li\u003e\n\n\u003cli\u003ePt100 or Pt1000, single or double, -200 ... +450 °C\u003c\/li\u003e\n\n\u003cli\u003e2-, 3- or 4-wire circuit, Class A to B1\/10DIN\u003c\/li\u003e\n\n\u003cli\u003eProtective tube 1.4571 (316Ti), Ø 6 mm, up to 600 °C\u003c\/li\u003e\n\n\u003cli\u003eNominal length 46 or 70 mm, maximum 200 mm\u003c\/li\u003e\n\n\u003cli\u003eStandard cable 2 m, maximum 6 m, PVC to glass silk\u003c\/li\u003e\n\n\u003cli\u003eVersion with three diameters as TCMC (WT-K1)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356927369542,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TCMD_produkt_94362d05-6d77-4d03-8405-fc81b00c5894.webp?v=1789243684"},{"product_id":"tkmd-widerstandsthermometer-mit-anschlusskopf-b-gl","title":"TKMD resistance thermometer with type B connection head, GL","description":"\u003cp\u003eThe \u003cstrong\u003eTKMD\u003c\/strong\u003e is a resistance thermometer with connection head B in the version with GL type approval, manufacturer type Müller \u003cstrong\u003eWT-MR1G\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is designed for fixed plant installation at measuring points where type approval is required: The manufacturer's data sheet shows the GL mark with the number \u003cstrong\u003eTAA00002H5\u003c\/strong\u003e. The aluminum \u003cstrong\u003econnection head\u003c\/strong\u003e accommodates a ceramic base with connection posts, the process connection at the head is \u003cstrong\u003eM24x1.5\u003c\/strong\u003e, the cable entry is \u003cstrong\u003eM20x1.5\u003c\/strong\u003e, and the protection class is \u003cstrong\u003eIP 54\u003c\/strong\u003e. The protection tube made of \u003cstrong\u003e1.4571 (316Ti)\u003c\/strong\u003e or \u003cstrong\u003e1.4401 (316)\u003c\/strong\u003e withstands \u003cstrong\u003eup to 600 °C\u003c\/strong\u003e, the process pressure is \u003cstrong\u003emax. PN16\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eCompared to the TKMC, this is not the same product with an additional mark: This version is limited to a length of \u003cstrong\u003e200 mm\u003c\/strong\u003e instead of 2000 mm and has a different sheath material and accessory kit. The source does not list a transmitter as an accessory here, but it does include connection cables up to 6 m, compression fittings, and sheet metal flanges. Screw-in (ES) and immersion (ET) designs are available, as well as protection tube diameters of \u003cstrong\u003e3 to 15 mm\u003c\/strong\u003e; the selection is limited for the sheathed element and in the immersion design.\u003c\/p\u003e\n\u003cp\u003eThe measuring element is a \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, single or double, in a \u003cstrong\u003e2-, 3- or 4-wire circuit\u003c\/strong\u003e, as a standard element or as a sheathed element. The sensor's operating range is \u003cstrong\u003e-200 ... +450 °C\u003c\/strong\u003e, and the accuracy ranges in five steps from \u003cstrong\u003eClass A to B1\/10DIN\u003c\/strong\u003e. The resistance is at the ceramic base in the head, the test voltage is \u003cstrong\u003e500 VDC\u003c\/strong\u003e, and the response time on the 3×0.4 mm tube is \u003cstrong\u003et90 5 s\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore ordering, please note:\u003c\/strong\u003e The approval is documented by a mark and number, not by a certificate – the manufacturer's data sheet does not name a certifying body, and the certificate is not available. The language versions contradict each other regarding the sheath material: The English page names 2.4816 (Inconel 600), while the German page and the order codes in both languages name \u003cstrong\u003e1.4401 (316)\u003c\/strong\u003e – 1.4401 applies here. A response time is missing for the other tube geometries. The ambient temperature is not the medium temperature: The head is limited to \u003cstrong\u003e480 °C\u003c\/strong\u003e, the element ends at \u003cstrong\u003e450 °C\u003c\/strong\u003e. IP 54 only applies to the connection head; the source does not specify a standard for the accuracy classes, and terminal assignment, CE mark, and explosion protection are missing. Both carry the product identification \u003cstrong\u003eKD\u003c\/strong\u003e, distinguished only by the first digit: \u003cstrong\u003e4 ... 7\u003c\/strong\u003e for the TKMD, 0 ... 3 for the \u003cstrong\u003eTKMC\u003c\/strong\u003e (WT-MR1) – the latter up to 2000 mm long and sheathed with 2.4816.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eGL type approval TAA00002H5, documented by mark and number\u003c\/li\u003e\n\n\u003cli\u003ePt100 or Pt1000, 2-, 3- or 4-wire circuit\u003c\/li\u003e\n\n\u003cli\u003eOperating range -200 ... +450 °C, Class A to B1\/10DIN\u003c\/li\u003e\n\n\u003cli\u003eProcess pressure max. PN16, installation lengths 50 to 200 mm\u003c\/li\u003e\n\n\u003cli\u003eProtection tube 1.4571 or 1.4401, Ø 3 to 15 mm, up to 600 °C\u003c\/li\u003e\n\n\u003cli\u003eConnection head B made of aluminum, IP 54, cable entry M20x1.5\u003c\/li\u003e\n\n\u003cli\u003eVersion without GL available as TKMC up to 2000 mm length\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356927467846,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TKMD_produkt_15586a12-ad89-4b0e-91b8-0781eec53f71.webp?v=1789243717"},{"product_id":"tcme-kabelfuehler-mit-passstueck","title":"TCME cable probe with adapter","description":"\u003cp\u003eThe \u003cstrong\u003eTCME\u003c\/strong\u003e is a resistance thermometer designed as a cable sensor with a fitting, manufacturer type Müller \u003cstrong\u003eWT-KH\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt measures where a mounting bore already exists: The \u003cstrong\u003efitting\u003c\/strong\u003e, a potted sleeve made of \u003cstrong\u003e1.4571\u003c\/strong\u003e, sits on the protective tube and guides the sensor precisely into the bore – no thread or flange is needed for this. You specify the diameter and length of the fitting, allowing the same sensor to fit an existing mounting. The protective tube made of \u003cstrong\u003e1.4571 (316Ti)\u003c\/strong\u003e is approved up to \u003cstrong\u003e600 °C\u003c\/strong\u003e and is available in \u003cstrong\u003eØ 4, 5, or 6 mm\u003c\/strong\u003e, with nominal lengths between 25 and 65 mm, or up to \u003cstrong\u003e2000 mm\u003c\/strong\u003e upon request. The protection class is \u003cstrong\u003eIP 65 up to 250 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt does not have a terminal compartment or electronics: The resistance value is directly available at open, bare ends of 70 mm, and the cable leads directly to the evaluation without an intermediate stage. A transmitter is not documented, therefore no current signal and no power supply either.\u003c\/p\u003e\n\u003cp\u003eMeasurements are taken with a \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, single or double, in \u003cstrong\u003e2-, 3- or 4-wire circuit\u003c\/strong\u003e and without insulation material. The sensor's operating range extends from \u003cstrong\u003e-200 ... +450 °C\u003c\/strong\u003e, and the accuracy can be ordered in five grades from \u003cstrong\u003eClass A to B1\/10DIN\u003c\/strong\u003e. For insulation, the manufacturer specifies a \u003cstrong\u003etest voltage of 500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore ordering, please note:\u003c\/strong\u003e The fitting is not a documented sealing element – the data sheet does not specify system pressure, sealing effect, or installation tolerance; anyone wishing to seal against a medium with it will need written confirmation. The operating range is determined by the cable, not the sensor: PVC only withstands \u003cstrong\u003e-5 ... +70 °C\u003c\/strong\u003e, glass fiber \u003cstrong\u003e-60 ... +550 °C\u003c\/strong\u003e – and the cable is in an environment that is not the medium temperature. \u003cstrong\u003eIP 65 does not apply to the version with screen braiding\u003c\/strong\u003e; what applies there is not stated in the sheet. The nominal length for Ø 4 mm is stated twice differently in the manufacturer's sheet, with 25 and with 35 mm; \u003cstrong\u003e25 mm\u003c\/strong\u003e has been adopted – please specify the length in plain text, as well as the temperature range in °C. The source does not specify a standard for the accuracy classes; CE marks and explosion protection are not documented, and this version does not carry a type approval – the version with \u003cstrong\u003eGL TAA00002H5\u003c\/strong\u003e is the \u003cstrong\u003eTCMF\u003c\/strong\u003e (WT-KHG). Both carry the product identification \u003cstrong\u003eKV\u003c\/strong\u003e and are distinguished solely by the \"sensor element\" location: 0 ... 3 is the WT-KH, 4 ... 7 is the WT-KHG.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eFitting as a potted sleeve made of 1.4571, dimensions as specified\u003c\/li\u003e\n\n\u003cli\u003ePt100 or Pt1000, single or double, 2-, 3- or 4-wire circuit\u003c\/li\u003e\n\n\u003cli\u003eOperating range -200 ... +450 °C, Class A to B1\/10DIN\u003c\/li\u003e\n\n\u003cli\u003eProtective tube 1.4571 (316Ti), Ø 4, 5 or 6 mm, up to 2000 mm upon request\u003c\/li\u003e\n\n\u003cli\u003eFive cable constructions from PVC to glass fiber, -5 ... +550 °C\u003c\/li\u003e\n\n\u003cli\u003eIP 65 up to 250 °C, not with screen braiding\u003c\/li\u003e\n\n\u003cli\u003eGL version available as TCMF (WT-KHG)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356927631686,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TCME_produkt_4115078f-819b-4be9-825b-82c9c45b783f.webp?v=1789243684"},{"product_id":"tcmf-kabelfuehler-mit-passstueck-gl","title":"TCMF cable probe with adapter, GL","description":"\u003cp\u003eThe \u003cstrong\u003eTCMF\u003c\/strong\u003e is a cable sensor with a fitting piece in the GL type-approved version, manufacturer type Müller \u003cstrong\u003eWT-KHG\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt measures where a mounting bore is already present and type approval is also required: The \u003cstrong\u003efitting piece\u003c\/strong\u003e, a cast sleeve made of \u003cstrong\u003e1.4571\u003c\/strong\u003e, sits on the protective tube and guides the sensor precisely into the bore – a thread or a flange is not necessary for this; you specify the diameter and length. The protective tube made of \u003cstrong\u003e1.4571 (316Ti)\u003c\/strong\u003e is approved up to \u003cstrong\u003e600 °C\u003c\/strong\u003e and is available in \u003cstrong\u003eØ 4, 5, or 6 mm\u003c\/strong\u003e; the nominal lengths are between 25 and 65 mm. The protection class is \u003cstrong\u003eIP 65 up to 250 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt differs from the TCME by its type approval: The manufacturer's sheet shows the GL mark with the number \u003cstrong\u003eGL TAA00002H5\u003c\/strong\u003e. For this, this version is shorter – the maximum length is \u003cstrong\u003e200 mm\u003c\/strong\u003e instead of 2000 mm, and the cable is at most \u003cstrong\u003e6 m\u003c\/strong\u003e. It also does not have a terminal compartment or electronics: The resistance value is directly at open, bare ends of 70 mm; a transmitter is not documented. \u003c\/p\u003e\n\u003cp\u003eMeasurements are taken with a \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, single or double, in \u003cstrong\u003e2-, 3-, or 4-wire configuration\u003c\/strong\u003e and without insulating material. The sensor's operating range extends from \u003cstrong\u003e-200 ... +450 °C\u003c\/strong\u003e; the accuracy can be ordered in five stages from \u003cstrong\u003eClass A to B1\/10DIN\u003c\/strong\u003e. For insulation, the manufacturer specifies a \u003cstrong\u003etest voltage of 500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e The approval is documented as a mark and number, not as a certificate – the manufacturer's sheet does not name a certifying body, and we do not have the certificate itself; it should be requested before making an assurance to a classification society. The fitting piece is not a documented sealing element: The datasheet does not specify system pressure, sealing effect, or installation tolerance. The operating range is determined by the cable, not the sensor – PVC only withstands \u003cstrong\u003e-5 ... +70 °C\u003c\/strong\u003e, glass fiber \u003cstrong\u003e-60 ... +550 °C\u003c\/strong\u003e, and the cable is in the environment, which is not the medium temperature. Terminal assignment is not documented, neither wire color nor terminal number. The source does not specify a standard for the accuracy classes; CE mark and explosion protection are not documented. Both versions carry the product identification \u003cstrong\u003eKV\u003c\/strong\u003e and are distinguished solely by the \"sensor element\" location: 4 ... 7 is the WT-KHG, 0 ... 3 is the WT-KH.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eGL type approval TAA00002H5 documented in the manufacturer's sheet\u003c\/li\u003e\n\n\u003cli\u003eFitting piece as a cast sleeve made of 1.4571, dimensions according to specification\u003c\/li\u003e\n\n\u003cli\u003ePt100 or Pt1000, 2-, 3- or 4-wire configuration\u003c\/li\u003e\n\n\u003cli\u003eOperating range -200 ... +450 °C, Class A to B1\/10DIN\u003c\/li\u003e\n\n\u003cli\u003eProtective tube 1.4571 (316Ti), Ø 4, 5 or 6 mm, maximum nominal length 200 mm\u003c\/li\u003e\n\n\u003cli\u003eCable in standard 2 m, maximum 6 m\u003c\/li\u003e\n\n\u003cli\u003eVersion without GL available up to 2000 mm as TCME (WT-KH)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356928155974,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TCMF_produkt_7c87b86b-2304-44d6-bb0d-0da994943bf3.webp?v=1789243684"},{"product_id":"tbmc-mantel-widerstandsthermometer","title":"TBMC mineral insulated resistance thermometer","description":"\u003cp\u003eThe \u003cstrong\u003eTBMC\u003c\/strong\u003e is a sheathed resistance thermometer with a flexible protective tube and fixed connection cable, manufacturer type Müller \u003cstrong\u003eWT-MK1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt measures in installation locations that a rigid protective tube cannot reach, and where a class better than a thermocouple is required. The sheathed tube can be bent to a radius of \u003cstrong\u003emin. 5 × Ø protective tube\u003c\/strong\u003e; the cable is firmly attached to the sensor, eliminating the need for a connection head. Protective tube \u003cstrong\u003e1.4401\u003c\/strong\u003e (316), specified as a material up to \u003cstrong\u003e600 °C\u003c\/strong\u003e, and connecting sleeve \u003cstrong\u003e1.4571\u003c\/strong\u003e (316Ti) provide \u003cstrong\u003eIP 65\u003c\/strong\u003e up to \u003cstrong\u003e250 °C\u003c\/strong\u003e. Available in \u003cstrong\u003e3 · 4.5 · 6 mm\u003c\/strong\u003e diameters with a wall thickness of 0.25 to 0.51 mm, the standard nominal length is \u003cstrong\u003e100 mm\u003c\/strong\u003e, up to \u003cstrong\u003e2000 mm\u003c\/strong\u003e on request. Compression fittings and sheet metal flanges are available as accessories.\u003c\/p\u003e\n\u003cp\u003eThe sensor is sluggish: for \u003cstrong\u003e6×0.5 mm\u003c\/strong\u003e, the manufacturer states \u003cstrong\u003et90 30.9 s\u003c\/strong\u003e and t50 12 s; for \u003cstrong\u003e6×1 mm\u003c\/strong\u003e, \u003cstrong\u003et90 22.1 s\u003c\/strong\u003e and t50 7.6 s. Connection is via open ends with wire end ferrules; five cable types from PVC to glass silk are available.\u003c\/p\u003e\n\u003cp\u003eThe measuring element is a \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, single or double, insulated in metal oxide and wired in \u003cstrong\u003e2-, 3- or 4-wire\u003c\/strong\u003e configuration. The sensor's operating range extends from \u003cstrong\u003e-200 ... +450 °C\u003c\/strong\u003e, with accuracy selectable in five stages from \u003cstrong\u003eClass A\u003c\/strong\u003e to \u003cstrong\u003eB1\/10DIN\u003c\/strong\u003e. The sensor outputs the resistance directly; a transmitter is not documented; insulation is tested with \u003cstrong\u003e500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore ordering, please note:\u003c\/strong\u003e The operating range is determined by the cable, not the sensor – PVC ends at \u003cstrong\u003e+70 °C\u003c\/strong\u003e, silicone at \u003cstrong\u003e+180 °C\u003c\/strong\u003e, PTFE at \u003cstrong\u003e+205 °C\u003c\/strong\u003e, glass silk at \u003cstrong\u003e+550 °C\u003c\/strong\u003e; only the glass silk version reaches the +450 °C of the sensor. Two four-wire sensors are only available with PTFE-silicone cable, so this version ends at +180 °C. The source does not specify any standard for the accuracy classes – if a class needs to be guaranteed, it must be confirmed by the manufacturer. The two response times contradict each other: the thicker 6×1 mm wall is stated as faster, and 1 mm is not in the wall thickness table. IP 65 does not apply to the version with braided shielding. Terminal assignment, process connection, system pressure, weight, CE mark, and explosion protection are not documented. Each order code begins with the product identifier \u003cstrong\u003eKM\u003c\/strong\u003e, the used temperature range must be specified in °C. The version with GL type approval is the \u003cstrong\u003eTBMD\u003c\/strong\u003e (WT-MK1G).\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003ePt100 or Pt1000, single or double, -200 ... +450 °C\u003c\/li\u003e\n\n\u003cli\u003eWiring in 2-, 3- or 4-wire freely selectable\u003c\/li\u003e\n\n\u003cli\u003eFive accuracy classes from Class A to B1\/10DIN\u003c\/li\u003e\n\n\u003cli\u003eFlexible sheathed tube, bending radius min. 5 × Ø protective tube\u003c\/li\u003e\n\n\u003cli\u003eThree diameters 3 · 4.5 · 6 mm, nominal length up to 2000 mm\u003c\/li\u003e\n\n\u003cli\u003eProtective tube 1.4401 (316), material up to 600 °C\u003c\/li\u003e\n\n\u003cli\u003eGL version available as TBMD (WT-MK1G)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356928319814,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TBMC_produkt_72d26594-15bb-4ddd-b26c-1ce689988940.webp?v=1789243659"},{"product_id":"tbmd-mantel-widerstandsthermometer-gl","title":"TBMD mineral insulated resistance thermometer, GL","description":"\u003cp\u003eThe \u003cstrong\u003eTBMD\u003c\/strong\u003e is a sheathed resistance thermometer with GL type approval, manufacturer type Müller \u003cstrong\u003eWT-MK1G\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is designed for systems where the sensor must carry a type approval from Germanischer Lloyd: \u003cstrong\u003eGL TAA00002H5\u003c\/strong\u003e. Compared to the \u003cstrong\u003eWT-MK1\u003c\/strong\u003e, the nominal length is limited to \u003cstrong\u003e200 mm\u003c\/strong\u003e and the connection cable to \u003cstrong\u003e6 m\u003c\/strong\u003e, but there is an additional diameter of \u003cstrong\u003e1.9 mm\u003c\/strong\u003e, which also fits into narrow boreholes. The sheath remains flexible with a minimum bending radius of \u003cstrong\u003e5 × Ø protection tube\u003c\/strong\u003e and reaches installation locations that a rigid protection tube cannot; the cable is fixed, and no connection head is required.\u003c\/p\u003e\n\u003cp\u003eProtection tube \u003cstrong\u003e1.4401\u003c\/strong\u003e (316), specified as a material up to \u003cstrong\u003e600 °C\u003c\/strong\u003e, and connection sleeve \u003cstrong\u003e1.4571\u003c\/strong\u003e (316Ti) carry \u003cstrong\u003eIP 65\u003c\/strong\u003e up to \u003cstrong\u003e250 °C\u003c\/strong\u003e; the nominal length is standard at \u003cstrong\u003e100 mm\u003c\/strong\u003e. Connection is made via open ends with wire end ferrules; five cable versions from PVC to glass silk are available. Compression fittings and sheet metal flanges are accessories.\u003c\/p\u003e\n\u003cp\u003eThe measuring element is a \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, single or double, insulated in metal oxide and wired in \u003cstrong\u003e2-, 3- or 4-wire\u003c\/strong\u003e circuitry. The sensor's operating range extends from \u003cstrong\u003e-200 to +450 °C\u003c\/strong\u003e, and accuracy can be selected in five steps from \u003cstrong\u003eClass A\u003c\/strong\u003e to \u003cstrong\u003eB1\/10DIN\u003c\/strong\u003e. The sensor outputs resistance directly; a transmitter is not documented; insulation is tested with \u003cstrong\u003e500 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e The approval is documented as a mark and number, not as a certificate; the certificate should be requested before any assurance is given to the classification society. Both versions bear the product identification \u003cstrong\u003eKM\u003c\/strong\u003e; they are distinguished solely by the sensor element position: \u003cstrong\u003e4 ... 7\u003c\/strong\u003e is the WT-MK1G, \u003cstrong\u003e0 ... 3\u003c\/strong\u003e is the WT-MK1 - a digit reversal orders the sensor without approval. The operating range is determined by the cable, not the sensor: PVC ends at +70 °C, silicone at +180 °C, PTFE at +205 °C, glass silk at +550 °C - only the glass silk version reaches the sensor's +450 °C. The source does not specify a standard for the accuracy classes. IP 65 does not apply to the version with braided shield. Wall thickness, terminal assignment, process connection, system pressure, weight, response time, CE mark, and explosion protection are not documented. The version without approval, with a nominal length of \u003cstrong\u003e2000 mm\u003c\/strong\u003e, is the \u003cstrong\u003eTBMC\u003c\/strong\u003e (WT-MK1).\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eType approval GL TAA00002H5 documented as a mark and number\u003c\/li\u003e\n\n\u003cli\u003ePt100 or Pt1000, single or double, -200 ... +450 °C\u003c\/li\u003e\n\n\u003cli\u003eCircuitry in 2-, 3- or 4-wire, Class A to B1\/10DIN\u003c\/li\u003e\n\n\u003cli\u003eFour diameters 1.9 · 3 · 4.5 · 6 mm, one more than the TBMC\u003c\/li\u003e\n\n\u003cli\u003eFlexible sheath, bending radius min. 5 × Ø protection tube\u003c\/li\u003e\n\n\u003cli\u003eNominal length 100 mm as standard, maximum 200 mm\u003c\/li\u003e\n\n\u003cli\u003eProtection tube 1.4401 (316), connection cable maximum 6 m\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356928549190,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TBMD_produkt_9be15878-5282-42b0-bac6-38484c92125f.webp?v=1789243659"},{"product_id":"tlmb-temperatur-grenzwertschalter","title":"TLMB temperature limit switch","description":"\u003cp\u003eThe \u003cstrong\u003eTLMB\u003c\/strong\u003e is a temperature limit switch with Pt100 and relay output, manufacturer type Müller \u003cstrong\u003eMETL-L\u003c\/strong\u003e. It does not output a measured value, but switches a relay as soon as the limit value is reached.\u003c\/p\u003e\n\u003cp\u003eIt is screwed into pipes or tanks and switches there without an evaluation unit, for example directly to a digital input of a PLC. The process connection and protective tube are made of \u003cstrong\u003e1.4571\u003c\/strong\u003e, the protective tube measures Ø 6 mm as standard or Ø 9 mm; the insertion length ranges from \u003cstrong\u003e50 to 1000 mm\u003c\/strong\u003e according to the key, the system pressure is \u003cstrong\u003ePN 25\u003c\/strong\u003e. The housing body and lid are made of PBT GF30, the circuit boards are potted, and the protection class is \u003cstrong\u003eat least IP 65\u003c\/strong\u003e. The weight is approximately \u003cstrong\u003e140 g\u003c\/strong\u003e, and the mounting position is arbitrary.\u003c\/p\u003e\n\u003cp\u003eThe switching point is set \u003cstrong\u003eon site with a magnet\u003c\/strong\u003e: without tools and without opening the housing. Instead of a display, there is a red LED, \u003cstrong\u003e360° visible\u003c\/strong\u003e – it lights up as long as the relay is active.\u003c\/p\u003e\n\u003cp\u003eThe input has a \u003cstrong\u003ePt100 in 3-wire circuit\u003c\/strong\u003e of class \u003cstrong\u003eB\u003c\/strong\u003e, class A as an option, in the range of \u003cstrong\u003e-50 ... +200 °C\u003c\/strong\u003e with an accuracy of \u003cstrong\u003e±0.5 °C\u003c\/strong\u003e. The switching point is set to \u003cstrong\u003e100 °C\u003c\/strong\u003e ex works, the hysteresis is \u003cstrong\u003e0.1 °C\u003c\/strong\u003e as standard. The output is a \u003cstrong\u003erelay with changeover contact\u003c\/strong\u003e: 1 A at 30 VDC or 0.3 A at 125 VAC at resistive load, for \u003cstrong\u003emore than 100,000 switching cycles\u003c\/strong\u003e. The switch is powered by \u003cstrong\u003e24 ... 30 VDC\u003c\/strong\u003e at approx. 35 mA including the relay circuit; the electrical connection is \u003cstrong\u003eM12x1 eight-pole\u003c\/strong\u003e as the only option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The manufacturer's overview page contradicts the data sheet – it states an open collector with 30 V and 200 mA, the data sheet states a changeover relay with 1 A and ±0.5 °C. We use the values from the data sheet; the output type must be confirmed with the manufacturer before ordering. Measuring and configuring are not possible simultaneously: For HART, pin 5 is connected via a 250 Ω resistor, and in this connection, the relay is not functional. Only the switching point can be changed with the magnet; hysteresis, switching delay, and damping are only possible via the HART tool, interface \u003cstrong\u003eDEV-HM\u003c\/strong\u003e. The ambient temperature is not the medium temperature: The medium can be up to +200 °C, the electronics in the head only up to +80 °C. A CE mark, explosion protection, and SIL or PL classification are not documented.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003ePt100 3-wire, Class B, Class A as an option\u003c\/li\u003e\n\n\u003cli\u003eRange -50 to +200 °C, accuracy ±0.5 °C\u003c\/li\u003e\n\n\u003cli\u003eSwitching point set on-site with magnet\u003c\/li\u003e\n\n\u003cli\u003eChangeover relay 1 A at 30 VDC, more than 100,000 switching cycles\u003c\/li\u003e\n\n\u003cli\u003eRed LED, 360° visible\u003c\/li\u003e\n\n\u003cli\u003eProtective tube 1.4571, Ø 6 or Ø 9 mm, PN 25\u003c\/li\u003e\n\n\u003cli\u003eAt least IP 65, potted circuit boards, approx. 140 g\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356931825990,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TLMB_produkt_cbb01634-a42b-404a-a6b6-905e93e134d2.webp?v=1789243717"},{"product_id":"teme-einschraub-temperatursensor-mit-programmierbarem-messumformer","title":"TEME screw-in temperature sensor with programmable transmitter","description":"\u003cp\u003eThe \u003cstrong\u003eTEME\u003c\/strong\u003e is a compact screw-in temperature sensor with a programmable transmitter, manufacturer type Müller \u003cstrong\u003eMKTS\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt measures where temperature is taken directly in the medium: in pipelines, tanks, hydraulic and cooling circuits. The sensor tube and housing are made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, the sensor is potted and protected with \u003cstrong\u003eIP 68\u003c\/strong\u003e, and the system pressure is \u003cstrong\u003emax. 25 bar\u003c\/strong\u003e. At around \u003cstrong\u003e200 g\u003c\/strong\u003e and with a sensor tube of Ø 6 mm, it is small enough for confined installation situations, and the mounting position is arbitrary.\u003c\/p\u003e\n\u003cp\u003eBecause the sensor, output, process connection, and connector can be freely combined, a single design covers a wide variety of systems – from a bare Pt100 directly on the connector to a CANopen node according to CiA 404, from pipe threads to connectors for mobile machines and vehicles (Deutsch DT04, Super Seal, Bayonet, MIL). Instead of stocking a separate device for each signal type and each part of the system, you order the same basic form in the appropriate configuration.\u003c\/p\u003e\n\u003cp\u003eMeasurement is performed with \u003cstrong\u003eone or two Pt100 or Pt1000\u003c\/strong\u003e in the range of \u003cstrong\u003e-50 ... +200 °C\u003c\/strong\u003e with a minimum span of \u003cstrong\u003e50 K\u003c\/strong\u003e. The transmitter operates with 24-bit resolution and an accuracy of \u003cstrong\u003emax. 0.1% of the range\u003c\/strong\u003e plus sensor error; for CANopen, it is ±0.1 K with a 20 ms conversion time. Two measuring elements are only possible in the version without a transmitter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore ordering, please note:\u003c\/strong\u003e The ambient temperature is not the medium temperature – the medium can be up to +200 °C, but the electronics in the head with a transmitter can only tolerate -20 ... +80 °C, and without a transmitter -30 ... +100 °C. The 0.1% only applies between 0 and +40 °C ambient temperature. The CANopen transmitter is calibrated at the factory and cannot be configured afterwards; the analog output can be set with the \u003cstrong\u003eDEV-KMA\u003c\/strong\u003e configurator and TrComm software. The MK identifier is used three times by this manufacturer (MKTS, MKTS-GL, MKTS-SP) – please state the type designation in plain text when inquiring. The EC declaration of conformity is available, but it dates from 25.07.2011 and still refers to directives 2004\/108\/EC and 97\/23\/EC, which were replaced in 2016; the datasheet itself does not show a CE mark. Explosion protection is not documented; the intrinsically safe version is the \u003cstrong\u003eTEMG\u003c\/strong\u003e (MKTS-Ex).\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eOne design for direct resistance, 4 ... 20 mA, 0 ... 10 V and CANopen\u003c\/li\u003e\n\n\u003cli\u003eMeasuring range -50 to +200 °C, accuracy max. 0.1% of range\u003c\/li\u003e\n\n\u003cli\u003eInstallation length 50 to 1000 mm in 5 mm increments\u003c\/li\u003e\n\n\u003cli\u003eSensor tube and housing made of stainless steel 1.4571, IP 65 \/ IP 68, max. 25 bar\u003c\/li\u003e\n\n\u003cli\u003eConnectors also for mobile machines and vehicles\u003c\/li\u003e\n\n\u003cli\u003eIntrinsically safe version available as TEMG\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356931989830,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TPMA_produkt_abeb0373-f63d-4f06-8fa2-4d8d6cebe2b7.webp?v=1789243717"},{"product_id":"thma-hand-temperatursensor","title":"THMA handheld temperature sensor","description":"\u003cp\u003eThe \u003cstrong\u003eTHMA\u003c\/strong\u003e is a handheld temperature sensor with a stainless steel handle, manufacturer type Müller \u003cstrong\u003eMKTS-HA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is designed for control measurements in liquids and soft substances: The operator dips the tube into the medium and reads the value – there is no installation point and no screw connection. The handle and protective tube are made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, and the protective tube measures \u003cstrong\u003eØ 6 × 0.5 mm\u003c\/strong\u003e. The tube length is available from \u003cstrong\u003e50 to 1000 mm\u003c\/strong\u003e, with the tube end flat, pointed, or optionally heated. The weight is approximately \u003cstrong\u003e450 g\u003c\/strong\u003e, and the protection class is at least \u003cstrong\u003eIP 65 with the connection plugged in\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe same handle can be ordered with very different outputs: the \u003cstrong\u003ePt100(0) directly on the connector\u003c\/strong\u003e and thus without power supply, \u003cstrong\u003e4 … 20 mA with HART\u003c\/strong\u003e in the 2-wire loop, or digital \u003cstrong\u003eCANopen\u003c\/strong\u003e, Modbus RTG, and \u003cstrong\u003ePROFIBUS DP\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe input features a \u003cstrong\u003ePt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e in 2-, 3- or 4-wire configuration in classes \u003cstrong\u003eA, B, and B 1\/2 DIN\u003c\/strong\u003e. The resolution is \u003cstrong\u003e16 bit\u003c\/strong\u003e, the accuracy \u003cstrong\u003e0.2 K or 0.08 % of the range\u003c\/strong\u003e, the response time \u003cstrong\u003e1 s\u003c\/strong\u003e; calibration is performed via \u003cstrong\u003e2 or 6 points\u003c\/strong\u003e, set via the HART tool. The HART loop requires \u003cstrong\u003e12 … 40 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e For a handheld device, two safety-relevant specifications are missing: a permissible handle or hand temperature and a maximum immersion depth are not documented in the manufacturer's data sheet – anyone measuring at +200 °C must determine for themselves how far the tube may be immersed and whether the handle is still touchable. The ambient temperature is not the medium temperature: permissible are -40 … +85 °C ambient and -50 … +200 °C medium. The source does not state which of the two accuracy specifications – 0.2 K or 0.08 % of the range – applies. The fault message is 3.8 mA at the lower end of the usable range of 3.8 … 20.8 mA; a wire break cannot be distinguished from a measurement at the beginning of the range. The heated tip is in the order key, but not in any data line – neither power nor voltage nor control; it must be requested from the manufacturer. Not every connection carries every signal: Two sensors in 3-wire connection only work with M12 eight-pin, AMP MIL, and cable; Super Seal and Deutsch DT04 three-pin do not carry the heating. The source writes \u003cstrong\u003eModbus RTG\u003c\/strong\u003e; such a protocol does not exist, Modbus RTU is meant. The data sheet does not mention a system pressure, a protection class in the unplugged state, a CE mark, a declaration of conformity, or explosion protection.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eHandle and protective tube made of stainless steel 1.4571, Ø 6 × 0.5 mm\u003c\/li\u003e\n\n\u003cli\u003eTube length 50 to 1000 mm, tube end flat, pointed or heated\u003c\/li\u003e\n\n\u003cli\u003ePt100 or Pt1000 in 2-, 3- or 4-wire connection\u003c\/li\u003e\n\n\u003cli\u003eClasses A, B and B 1\/2 DIN, medium -50 … +200 °C\u003c\/li\u003e\n\n\u003cli\u003eResistance directly, 4 … 20 mA with HART or digital\u003c\/li\u003e\n\n\u003cli\u003eAccuracy 0.2 K or 0.08 % of the range, response time 1 s\u003c\/li\u003e\n\n\u003cli\u003eIP 65 with plugged-in connection, weight approximately 450 g\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356932251974,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/THMA_produkt_2cf31cdd-001a-4836-8380-d673d5417192.webp?v=1789243685"},{"product_id":"tnma-einstech-thermometer-hart","title":"TNMA insertion thermometer, HART","description":"\u003cp\u003eThe \u003cstrong\u003eTNMA\u003c\/strong\u003e is an immersion thermometer in the form of a handheld lance with HART, manufacturer type Müller \u003cstrong\u003eMKTS-EL\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is designed for mobile use – hay, compost, hot asphalt: The lance is inserted into the material until the tip is deep enough. It is available in lengths from \u003cstrong\u003e500 to 2000 mm\u003c\/strong\u003e and upon request, with \u003cstrong\u003eØ 10 mm\u003c\/strong\u003e made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e. The weight is approximately \u003cstrong\u003e845 g\u003c\/strong\u003e (1000 mm with display), the protection class is \u003cstrong\u003eIP 65 for the electronics and IP 68 for the sensor\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe process connection is explicitly listed in the data sheet as a \u003cstrong\u003ehandheld lance, no installation\u003c\/strong\u003e: There are no threads or sealing surfaces. Readings are taken directly from the handle – the \u003cstrong\u003e7-segment LCD\u003c\/strong\u003e has a resolution of \u003cstrong\u003e0.1 °C\u003c\/strong\u003e, its accuracy is ±1% or 1°C, whichever is greater, and it runs on a \u003cstrong\u003eCR 2032 battery\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAt the input, there is a \u003cstrong\u003ePt100 in 3-wire circuit\u003c\/strong\u003e in classes A, B, and AA, or alternatively a \u003cstrong\u003eType K thermocouple\u003c\/strong\u003e. The maximum range extends from \u003cstrong\u003e-50 ... +400 °C\u003c\/strong\u003e with a smallest span of 50 K. The output is either the \u003cstrong\u003eresistance directly on the connector\u003c\/strong\u003e or \u003cstrong\u003e4 ... 20 mA with HART\u003c\/strong\u003e in the 2-wire loop; the total accuracy via HART is \u003cstrong\u003e0.3% of the range\u003c\/strong\u003e at 16 bit. The transmitter is supplied from the current loop with \u003cstrong\u003e10 ... 35 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The sensor ranges up to +400 °C, but the factory setting of the transmitter only goes up to +200 °C; if you want to measure higher, you must specify the configuration as custom. The ambient temperature is not the medium temperature: With the transmitter, -20 ... +80 °C is permissible, without the transmitter -30 ... +100 °C, the medium may have -50 ... +400 °C. Supply and burden formula do not match: 10 ... 35 VDC are specified, but the burden formula calculates with UB - 12 V and results in a negative value below 12 V; sister sheets consistently state 12 ... 40 VDC. The source provides no information on the lifespan of the CR 2032 battery or battery regulations. A statement \"system pressure 25 bar\" is on the sheet, but has no discernible meaning for a handheld lance without a process connection – suitability for process pressure is therefore not proven. Super Seal and Deutsch DT04 three-pole only lead one sensor. Configuration is done using the \u003cstrong\u003eHART interface with USB and software\u003c\/strong\u003e (01310-00220). A CE mark, a declaration of conformity, and explosion protection are not documented in the data sheet.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a Glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eHandheld lance Ø 10 mm in 500 to 2000 mm length – no installation required\u003c\/li\u003e\n\n\u003cli\u003ePt100 in 3-wire circuit or Type K thermocouple\u003c\/li\u003e\n\n\u003cli\u003eMedium -50 ... +400 °C, accuracy 0.3% of range at 16 bit\u003c\/li\u003e\n\n\u003cli\u003e4 ... 20 mA with HART or resistance directly on the connector\u003c\/li\u003e\n\n\u003cli\u003eDisplay on handle with 0.1 °C resolution, CR 2032 battery\u003c\/li\u003e\n\n\u003cli\u003eLance made of stainless steel 1.4571, IP 65 \/ IP 68\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356932514118,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TNMA_produkt_7ddcdd9d-ce9b-4939-8553-8159af3458b3.webp?v=1789243717"},{"product_id":"temg-eigensicherer-kompakt-temperatursensor","title":"TEMG intrinsically safe compact temperature sensor","description":"\u003cp\u003eThe \u003cstrong\u003eTEMG\u003c\/strong\u003e is an intrinsically safe compact temperature sensor for hazardous areas, manufacturer type Müller \u003cstrong\u003eMKTS-Ex\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIt covers measuring points in gas-hazardous areas – tanks, separators, pipelines with flammable media – without explosion-proof encapsulation or separating component in the field. The sensor tube, housing body and plug insert are made entirely of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, the system pressure is \u003cstrong\u003emax. 25 bar\u003c\/strong\u003e, and the protection class is \u003cstrong\u003eIP 65 \/ IP 68\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIt is the intrinsically safe version of the same design platform: same housing, same outputs, plus \u003cstrong\u003eATEX\u003c\/strong\u003e and \u003cstrong\u003eIECEx\u003c\/strong\u003e for Zone 0.\u003c\/p\u003e\u003cp\u003eMeasurement is performed with \u003cstrong\u003eone or two Pt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e, only in \u003cstrong\u003eClass A\u003c\/strong\u003e, at \u003cstrong\u003emax. 0.1 % of the range\u003c\/strong\u003e. The measurement range of the data table extends from \u003cstrong\u003e-50 … +200 °C\u003c\/strong\u003e, the smallest span is \u003cstrong\u003e50 K\u003c\/strong\u003e; the medium temperature additionally limits the temperature class: \u003cstrong\u003e+425 °C in T1\u003c\/strong\u003e, +275 °C in T2, +180 °C in T3, +115 °C in T4, +80 °C in T5 and \u003cstrong\u003e+65 °C in T6\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBefore ordering, please note:\u003c\/strong\u003e The marking is \u003cstrong\u003eII 1 G Ex ia IIC T6..T1 Ga\u003c\/strong\u003e, plus II 1\/2 G Ga\/Gb and II 2 G Gb; Zone 0, 1 and 2 are approved for gases. The intrinsically safe maximum values at both outputs are \u003cstrong\u003eUi 30 VDC, Ii 110 mA, Pi 1 W\u003c\/strong\u003e, passive 30 V, 100 mA and 100 mW, with \u003cstrong\u003eCi 66 nF\u003c\/strong\u003e and \u003cstrong\u003eLi 330 µH\u003c\/strong\u003e (330 m cable). Both certificate numbers end with X – \u003cstrong\u003eTÜV 21 ATEX 201293 X\u003c\/strong\u003e and \u003cstrong\u003eIECEx TUN 21.0005X\u003c\/strong\u003e – and include special conditions; the source mentions heat backflow, impact and friction, and electrostatic charging. The permissible ambient temperature depends on the temperature class and the output type: current output -40 … +75 °C, voltage output only -40 … +50 °C, passive -50 … +100 °C; in T5 and T6, the source calculates the limit from the power dissipation, the corresponding table should be read before design. Measurement range and medium temperature contradict each other in the data sheet: feature bar -50 … +200 °C, data table -50 … +425 °C, plus the limit per temperature class – the smallest of the three values applies. Two measuring elements are only available without a transmitter; the installation length (10 … 300 mm) must be specified. The product identification GN also appears verbatim on the MKTS-GLEx sheet; please specify the type designation in plain text. Configuration is done with the \u003cstrong\u003eDEV-KMA\u003c\/strong\u003e and TrComm. The data sheet mentions \u003cstrong\u003e2014\/34\/EU\u003c\/strong\u003e as a guideline; a CE mark is not documented there. The certificates are available on request and for download according to the source, we do not have them. The version with additional marine approval is the \u003cstrong\u003eTEMF\u003c\/strong\u003e (MKTS-GLEx).\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eMarking II 1 G Ex ia IIC T6..T1 Ga, Zone 0, 1 and 2 for gases\u003c\/li\u003e\n\n\u003cli\u003eATEX TÜV 21 ATEX 201293 X and IECEx TUN 21.0005X, both with X\u003c\/li\u003e\n\n\u003cli\u003ePt100 or Pt1000 in Class A, max. 0.1 % of the range\u003c\/li\u003e\n\n\u003cli\u003eMedium temperature up to +425 °C in T1, +65 °C in T6\u003c\/li\u003e\n\n\u003cli\u003eUi 30 VDC, Ii 110 mA, Pi 1 W, Ci 66 nF, Li 330 µH\u003c\/li\u003e\n\n\u003cli\u003e4 … 20 mA, 0…10 V or resistance directly at the connector\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356932546886,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TPMC_produkt_f044c3e0-b2af-4bde-9c66-ccac6c918a85.webp?v=1789243717"},{"product_id":"txma-schienen-temperatursensor","title":"TXMA rail temperature sensor","description":"\u003cp\u003eThe \u003cstrong\u003eTXMA\u003c\/strong\u003e is a rail temperature sensor for railway applications, manufacturer type Müller \u003cstrong\u003eSTSBA\u003c\/strong\u003e. It measures the temperature of the running rail and provides the measured value that controls the \u003cstrong\u003epoint heating system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe housing fits rail profiles \u003cstrong\u003eS 49, S 54, UIC 60, and R 65\u003c\/strong\u003e without modification. It is fastened with a \u003cstrong\u003eclamp and counter-clamp\u003c\/strong\u003e using an \u003cstrong\u003eM10\u003c\/strong\u003e threaded rod of strength class 10.9, tightening torque \u003cstrong\u003e68 Nm\u003c\/strong\u003e; installation must be \u003cstrong\u003ebelow the heating element\u003c\/strong\u003e, otherwise, the sensor will measure the heating system instead of the rail. The housing measures \u003cstrong\u003e68 × 64 mm\u003c\/strong\u003e, is fully potted, made of material \u003cstrong\u003ex 25 CrNiSi 18.9\u003c\/strong\u003e and weighs approximately \u003cstrong\u003e1.5 kg\u003c\/strong\u003e; the operating temperature ranges from \u003cstrong\u003e-40 … +85 °C\u003c\/strong\u003e, optionally -50 … +105 °C.\u003c\/p\u003e\n\u003cp\u003eThere is no plug: The connection cable \u003cstrong\u003eH07BQ-F, 2 × 1.5 mm²\u003c\/strong\u003e is led out of the potting via a \u003cstrong\u003ePG 11\u003c\/strong\u003e screw connection. The output is \u003cstrong\u003egalvanically isolated\u003c\/strong\u003e, the insulation voltage is \u003cstrong\u003e1500 VAC for 60 s\u003c\/strong\u003e – in the track, where traction currents and return current flow, this is the decisive value.\u003c\/p\u003e\n\u003cp\u003eA \u003cstrong\u003ePt100 in 4-wire Class A configuration\u003c\/strong\u003e is installed in the housing as the measuring element. The measuring range is configurable and set ex works to \u003cstrong\u003e-30 … +60 °C\u003c\/strong\u003e, the resolution is \u003cstrong\u003e0.1 °C\u003c\/strong\u003e, and the measurement deviation is less than \u003cstrong\u003e±0.05 % of the measuring span\u003c\/strong\u003e. The output is \u003cstrong\u003e4 … 20 mA\u003c\/strong\u003e in 2-wire technology, \u003cstrong\u003ereversible to 20 … 4 mA\u003c\/strong\u003e, with output limits \u003cstrong\u003e3.8 … 20.5 mA according to NAMUR\u003c\/strong\u003e. The sensor is powered with \u003cstrong\u003e9 … 36 VDC\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e A railway standard is not documented – the sheet refers to a \"Technical Approval from Deutsche Bahn AG\" but does not provide a number or date, and EN 50121, EN 50155, and EN 45545 are not mentioned; proof of compliance must be requested from the manufacturer before use in railway applications. The 1500 VAC for 60 s is insulation voltage, not continuous operating insulation; an overvoltage category and lightning protection are not specified. The data sheet does not state a degree of protection – the housing is fully potted, an IP code is missing. To change the measuring range, the \u003cstrong\u003econfiguration set with DTM-Control software\u003c\/strong\u003e is required, connection via \u003cstrong\u003eRS 232-C\u003c\/strong\u003e; if configured during operation, the connection to the point heating control is interrupted, and whether the set is still available must be clarified with the manufacturer. A CE mark and explosion protection are not documented.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a Glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eFits S 49, S 54, UIC 60, and R 65 without modification\u003c\/li\u003e\n\n\u003cli\u003ePt100 4-wire Class A, resolution 0.1 °C\u003c\/li\u003e\n\n\u003cli\u003e4 … 20 mA, reversible to 20 … 4 mA, limits 3.8 … 20.5 mA according to NAMUR\u003c\/li\u003e\n\n\u003cli\u003eGalvanically isolated, insulation voltage 1500 VAC for 60 s\u003c\/li\u003e\n\n\u003cli\u003eHousing 68 × 64 mm stainless steel, fully potted, approx. 1.5 kg\u003c\/li\u003e\n\n\u003cli\u003eClamp with M10 threaded rod, tightening torque 68 Nm\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356932677958,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TXMA_produkt_5edabb5d-a1eb-43c9-8956-cdd96af24a10.webp?v=1789243719"},{"product_id":"temh-kompakt-temperatursensor-mit-io-link","title":"TEMH compact temperature sensor with IO-Link","description":"\u003cp\u003eThe \u003cstrong\u003eTEMH\u003c\/strong\u003e is a compact temperature sensor with an IO-Link interface, manufacturer type Müller \u003cstrong\u003eMKTS-IO\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIt measures where the temperature is taken directly in the medium – in pipelines, tanks, hydraulic and cooling circuits. The sensor tube Ø 6 mm and housing are made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, the electronics are potted (\u003cstrong\u003eIP 65 \/ IP 68\u003c\/strong\u003e), and the system pressure is \u003cstrong\u003emax. 25 bar\u003c\/strong\u003e. The insertion length ranges from 50 to 1000 mm, and the mounting position is arbitrary.\u003c\/p\u003e\u003cp\u003eThe benefit lies in its digital integration: the measured value is sent via \u003cstrong\u003eIO-Link\u003c\/strong\u003e to the master, where the sensor is also parameterized – without a configuration device and without analog wiring; the settable values are described in the device file \u003cstrong\u003eIODD MKTS\u003c\/strong\u003e. As the only one in the series, it also accommodates \u003cstrong\u003etype J, K, and N thermocouples\u003c\/strong\u003e, thereby covering measurement points with existing thermocouple wiring. Electrically, there is exactly one connection, \u003cstrong\u003eM12x1 four-pin\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eThe input contains \u003cstrong\u003ea Pt100\u003c\/strong\u003e in a \u003cstrong\u003e3-wire circuit\u003c\/strong\u003e in classes A, B, and AA, class C on request, or alternatively a thermocouple. The nominal range for all elements is from \u003cstrong\u003e-50 … +200 °C\u003c\/strong\u003e. The source states the accuracy as \u003cstrong\u003emax. 0.02 % of the range\u003c\/strong\u003e plus sensor error at \u003cstrong\u003e16 bit\u003c\/strong\u003e and \u003cstrong\u003e20 ms\u003c\/strong\u003e response time; the sensor is powered with \u003cstrong\u003e24 VDC\u003c\/strong\u003e with reverse polarity protection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The ambient temperature is not the medium temperature – the medium may be up to +200 °C, but the electronics in the head only tolerate -20 … +80 °C; the source does not state what neck length or insulation is required for this. The accuracy specification contradicts the sister sheets: here, 0.02 % of the range is stated for 16-bit resolution, while the 24-bit versions only guarantee 0.1 % – the better value is on the coarser converter, which needs to be confirmed with the manufacturer before design. Filters and response time also do not match: 25 s filter at 20 ms response time, without explanation in the source. The product identification is not unambiguously documented: the order key has a placeholder in the second position, the product overview lists MX – please specify the type designation in plain text. A CE mark is not documented, and a declaration of conformity is not available; regarding the IO-Link interface, the source names the specification but no version number or test certificate. Explosion protection is not documented.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eIO-Link interface with signal level 0\/24 V, parameterization via the master\u003c\/li\u003e\n\n\u003cli\u003eAs the only one in the series, also type J, K, and N thermocouples\u003c\/li\u003e\n\n\u003cli\u003ePt100 3-wire in classes A, B, and AA\u003c\/li\u003e\n\n\u003cli\u003eNominal range -50 to +200 °C for each element\u003c\/li\u003e\n\n\u003cli\u003eA single M12x1 four-pin connection, no variety of connectors\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356933890374,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TPME_produkt_41cde47e-8c9e-4325-98c9-99709e30d2df.webp?v=1789243718"},{"product_id":"tpmf-standard-temperatursensor","title":"TPMF standard temperature sensor","description":"\u003cp\u003eThe \u003cstrong\u003eTPMF\u003c\/strong\u003e is a standard temperature sensor without electronics, manufacturer type Müller \u003cstrong\u003eSTS\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIt measures directly in the medium and is installed using a \u003cstrong\u003ecompression fitting G1\/4\" or G1\/2\"\u003c\/strong\u003e. The material throughout is stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, the sensor tube measures \u003cstrong\u003eØ 6 × 0.5 mm\u003c\/strong\u003e, the total length is \u003cstrong\u003e163 mm\u003c\/strong\u003e, of which 140 mm is tube, the housing body is completely potted internally, protection class \u003cstrong\u003eIP 67\u003c\/strong\u003e when connected, installation position is arbitrary. At \u003cstrong\u003eapprox. 23 g\u003c\/strong\u003e, it is the lightest in the series and hardly strains the measuring point.\u003c\/p\u003e\u003cp\u003eIt is the basic type of the series and solves a procurement problem, not a metrological one: It has \u003cstrong\u003eno order key, but a single order number 100-02161\u003c\/strong\u003e. Where otherwise ten digits would have to be set correctly – transmitter, number of wires, class, installation length, process connection, connector insert, configuration – there is only one version here.\u003c\/p\u003e\u003cp\u003eThe measuring element is \u003cstrong\u003ea Pt100\u003c\/strong\u003e in a \u003cstrong\u003e4-wire circuit\u003c\/strong\u003e of \u003cstrong\u003eClass A\u003c\/strong\u003e, the measuring range of the medium extends from \u003cstrong\u003e-20 … +150 °C\u003c\/strong\u003e. The sensor is a \u003cstrong\u003epassive measuring element\u003c\/strong\u003e and provides a resistance: The four wires are directly connected to the four pins of the \u003cstrong\u003eM12x1, four-pole, A-coded\u003c\/strong\u003e connector, a transmitter is not present. This means there is nothing to power and nothing to configure.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNote before ordering:\u003c\/strong\u003e The ambient temperature is not the medium temperature – the medium may be up to +150 °C warm, the head tolerates only -20 … +80 °C, storage -20 … +85 °C; the source does not state what neck length or insulation is required for this, condensation is harmless. The system pressure of \u003cstrong\u003emax. 10 bar\u003c\/strong\u003e is the smallest in this series – the other MKTS versions support 25 bar; the data sheet does not state the reason, but the compression fitting is a plausible explanation. The compression fitting is not included in the scope of delivery and has its own order numbers: G1\/4\" is \u003cstrong\u003e047-00067\u003c\/strong\u003e, G1\/2\" is \u003cstrong\u003e047-00066\u003c\/strong\u003e, steel clamping ring, material stainless steel 1.4571, for Ø 6 mm; the corresponding socket and the six connection cables from the source are also not included. This version does not offer other elements, other classes, or a different number of wires. The source does not specify a standard for Class A. A CE mark is not documented, a declaration of conformity is not available; explosion protection is also not documented.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eA single order number 100-02161, no order key\u003c\/li\u003e\n\n\u003cli\u003ePt100 Class A in 4-wire circuit, passive without power supply\u003c\/li\u003e\n\n\u003cli\u003eMedium -20 to +150 °C, ambient -20 to +80 °C\u003c\/li\u003e\n\n\u003cli\u003eOnly approx. 23 g, total length 163 mm, 140 mm tube\u003c\/li\u003e\n\n\u003cli\u003eM12x1 four-pole A-coded, resistance directly on the pins\u003c\/li\u003e\n\n\u003cli\u003eThroughout stainless steel 1.4571, protection class IP 67, max. 10 bar\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356934218054,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TPMF_produkt_3cb47d57-a333-4cf7-af3a-3cf9dec36179.webp?v=1789243718"},{"product_id":"tpmg-kompakt-temperatursensor-in-hygienischer-ausfuehrung-mit-hart","title":"TPMG hygienic compact temperature sensor with HART","description":"\u003cp\u003eThe \u003cstrong\u003eTPMG\u003c\/strong\u003e is a compact temperature sensor in a hygienic design with HART, manufacturer type Müller \u003cstrong\u003eMHY-TS\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIt is the hygienic version of the same design platform: The process connection is \u003cstrong\u003eG1\/2\" in a hygienic design\u003c\/strong\u003e or an immersion probe, sensor tube, process connection and housing are continuously made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, the connector insert is always metal – plastic is not provided. It is designed for measuring points that are cleaned and where no plastic should be in contact with the medium. The system pressure is \u003cstrong\u003emax. 25 bar\u003c\/strong\u003e, the protection class \u003cstrong\u003eIP 65 \/ IP 68\u003c\/strong\u003e, the installation length 50 to 1000 mm.\u003c\/p\u003e\u003cp\u003eOne design covers several signal types: \u003cstrong\u003e4 … 20 mA with HART\u003c\/strong\u003e in the 2-wire loop, \u003cstrong\u003eCANopen\u003c\/strong\u003e according to CiA 404, or the version without a transmitter with connections directly on the plug. The HART transmitter is set with the \u003cstrong\u003eHART interface with USB and software\u003c\/strong\u003e, order number \u003cstrong\u003e01310-00220\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eThe input has \u003cstrong\u003eone or two Pt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e in classes A, B, and AA. The measuring range extends from \u003cstrong\u003e-50 … +200 °C\u003c\/strong\u003e, the smallest span is \u003cstrong\u003e50 K\u003c\/strong\u003e. The total accuracy via HART is \u003cstrong\u003e0.3% of the range\u003c\/strong\u003e at \u003cstrong\u003e16 bit\u003c\/strong\u003e resolution and 10 measurements per second, via CANopen at \u003cstrong\u003e±0.1 K\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The datasheet does not mention a hygiene approval. The sheet describes the sensor as hygienic but does not document EHEDG or 3-A, no surface roughness Ra, no information on cleanability, no sealing materials, and no FDA conformity; only material 1.4571 and the G1\/2\" hygienic process connection are confirmed – those who need approval must request it from the manufacturer. The ambient temperature is not the medium temperature: The medium can be up to +200 °C, the electronics in the head tolerate only -20 … +80 °C with a transmitter, and -30 … +100 °C without a transmitter. For CANopen, only the eight-pin connector is suitable because the CAN bus pinout requires five pins – shield, plus, ground, CAN High, and CAN Low. The CANopen transmitter is calibrated at the factory; only the HART transmitter can be adjusted later. When communicating via a HART modem, a resistance of \u003cstrong\u003e250 Ω\u003c\/strong\u003e must be considered. The sheet does not mention a CE mark, a directive, or a declaration of conformity; explosion protection is also not documented.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eProcess connection G1\/2\" hygienic or immersion probe\u003c\/li\u003e\n\n\u003cli\u003eSensor tube, connection and housing continuously made of stainless steel 1.4571\u003c\/li\u003e\n\n\u003cli\u003eConnector insert always metal, no plastic on the device\u003c\/li\u003e\n\n\u003cli\u003e4 … 20 mA with HART or CANopen according to CiA 404\u003c\/li\u003e\n\n\u003cli\u003eTotal accuracy 0.3% of the range at 16 bit, measuring range -50 to +200 °C\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356934775110,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TPMG_produkt_4fda4d2f-f426-4e8b-8bdc-5938eddb5541.webp?v=1789243718"}],"url":"https:\/\/octogon.org\/en\/collections\/compact-temperature-sensors.oembed","provider":"octogon GmbH","version":"1.0","type":"link"}